Sourced from Bailey's combined September 2023 owner's manual covering the full 2024-season caravan range (Alicanto, Discovery, Pegasus Grande GT75, Phoenix II GT75, Unicorn). Range-specific wiring/electrical appendix details differ by range - see the appliance sections for details common across the range.
View official manual on manufacturer's site ↗Also Fitted To This Caravan
Master Troubleshooting & Diagnostics Matrix
| Error Code / Indicator | Symptom / Meaning | Possible Cause | Step-by-Step DIY Fix | Suggested Actions |
|---|---|---|---|---|
N/A | Pump will not run | No power to pump | Check power supply, check the mains isolator switch is on, and check the pump isolator switch is on. | DIY Safe |
N/A | Pump will not run | Fuse has blown | Replace fuse (do not exceed recommended fuse size). | DIY Safe |
N/A | Pump will not run | Blockage in pipework | Check pipework for kinks and check pipework for blockage. | DIY Safe |
N/A | Pump runs but no water appears | No water available | Make sure the water tank isn't empty and the filter cap isn't clogged. | DIY Safe |
N/A | Pump runs but no water appears | Water leaking from system | Go over the pipework and connections for leaks, repairing as needed, and confirm the water system's drain plugs are shut. | DIY Safe |
N/A | Pump runs but will not switch off | Water leaking from system | Go over the pipework and connections for leaks, repairing as needed, and confirm the water system's drain plugs are shut. | DIY Safe |
N/A | Pump runs but will not switch off | No water available | Make sure the water tank isn't empty and the filter cap isn't clogged. | DIY Safe |
N/A | Pump cycles on and off periodically when all the taps are closed (normal with partially opened tap) | Water leaking from system | Look over the pipework and fittings for leaks, fixing any found, and confirm the water system's drain plugs are shut. | DIY Safe |
N/A | Pump cycles on and off periodically when all the taps are closed (normal with partially opened tap) | Pressure switch | Check pressure switch settings. | DIY Safe |
N/A | Pump cycles on and off periodically when all the taps are closed (normal with partially opened tap) | Power supply to pump | Check battery is not discharged. | DIY Safe |
N/A | Low flow | Blockage in pipework | Check pipework for kinks and check pipework for blockages. | DIY Safe |
N/A | Low flow | Power supply to the pump | Check battery is not discharged. | DIY Safe |
N/A | Low flow | Jubilee clips tightened too far, crushing the pipework or connections | Replace damaged connections. | DIY Safe |
N/A | Low flow | Water leaking from system | Look over the pipework and fittings for leaks, fixing any found, and confirm the water systems' drain plugs are shut. | DIY Safe |
Frequently Asked Questions
Q: How do I drain down and winterize the water system before I stop using the caravan?
If you can, angle or tilt the caravan so its drain points sit at the lowest spot, then cut power to the pumps from the control panel. Turn every tap and mixer to roughly the halfway position, not forgetting an external shower point if your caravan has one, then pull off the shower handset to empty out any trapped water.
Next, let the water heater empty through its own drain valve, and do the same for the on-board tank's valve where fitted, leaving both open afterwards. If your caravan has grey waste tanks, pull the plugs from the sinks and open their own drain tap too, plus any other drainage points around the vehicle. Empty the external pump or aqua-source last and bring it inside for storage over winter.
Bear in mind the shower tray tends to hold onto a little water regardless - you'll likely need to mop up the last bit by hand. And double-check any ceramic-disc mixer tap handles are pushed all the way up to central, otherwise one side won't drain fully and you risk frost damage that your warranty won't cover.