Truma • Solar & Battery Charging

Truma SDC 12 Solar Dual Battery Charger

Official technical documentation and workshop diagnostics for Solar Charge Controller.

View official manual on manufacturer's site ↗

Technical Specifications

Battery TypesGel, AGM (Absorbed Glass Mat) or liquid electrolyte, 12V lead-acid (6 single cells), 50-110Ah
Not Suitable For6V batteries, non-chargeable batteries, nickel-cadmium batteries
Controller TypeMPPT (Maximum Power Point Tracker) - an electronic DC-DC converter that optimises the match between the solar panels and battery
Device Elements01. Main fuse 20A / 02. DIP switches for battery type / 03. Solar input terminals (Pos/Neg) / 04. Main battery output terminals (Pos/Neg) / 05. Starter battery output terminal (Pos only) / 06. Temperature sensor socket (optional) / 07. LCD meter socket (optional) / 08. Status indication LEDs
Overvoltage ProtectionSolar controllers protect themselves against excessive battery voltage or switch off with defective additional charging systems (threshold 15.0-16.0V); sensitive consumers are protected by a charging voltage limit of 14.8V maximum
Compatible Solar ModulesTruma SM 25, 40, 65, 80, 100, 120, 150 or 180

Master Troubleshooting & Diagnostics Matrix

Error Code / IndicatorSymptom / MeaningStep-by-Step DIY FixSuggested Actions
N/A
'Batt Low' LED illuminated
Possible Cause: Main battery voltage is below 10.5V, the battery is discharged, has an insufficient connection, or the supply fuse has failed.
Check the battery connection and supply fuse, and charge or replace the battery as needed. If this does not solve the problem, contact Truma Service.DIY Check / Tech Fallback
N/A
'MPP' LED illuminated
Possible Cause: N/A - this is normal.
The charge controller is charging the battery. No action needed.DIY Safe
N/A
'MPP' LED short flashing
Possible Cause: N/A - this is normal.
The charge controller is ready to charge. No action needed.DIY Safe
N/A
'>80%' LED illuminated
Possible Cause: N/A - this is normal.
The main battery is almost fully charged. No action needed.DIY Safe
N/A
'>80%' LED flashing at 1 pulse/sec
Possible Cause: The charge controller has overheated.
Allow the controller to cool and check ventilation around the unit. If this does not solve the problem, contact Truma Service.DIY Check / Tech Fallback
N/A
'>80%' LED flashing at 2 pulses/sec
Possible Cause: Main battery or solar panel overvoltage.
Check the battery and solar panel connections and voltages. If this does not solve the problem, contact Truma Service.DIY Check / Tech Fallback
N/A
'Batt Full' LED illuminated
Possible Cause: N/A - this is normal.
The battery is fully charged. No action needed.DIY Safe
N/A
All LEDs flashing
Possible Cause: Battery type selection (DIP switches) is incorrect.
Check the DIP switch configuration on the Charge Controller's bottom face matches the battery type actually fitted. If this does not solve the problem, contact Truma Service.DIY Check / Tech Fallback

Also Fitted In