Truma • Heating & Water

Truma CP plus

Official technical documentation and workshop diagnostics for CP plus.

View official manual on manufacturer's site ↗

Technical Specifications

Operating Voltage8 V – 16.5 V DC
Power Consumptionmax. 65 mA (100% background lighting) / 6.5 mA – 10 mA (stand-by) / 3 mA (Off)
Dimensions Cutout92 x 103 x 40 mm

Master Troubleshooting & Diagnostics Matrix

Error Code / IndicatorSymptom / MeaningPossible CauseStep-by-Step DIY FixSuggested Actions
W 17 H
Warning Water overheat condition (woc)
Water temperature inside the container has exceeded normal limits
Switch the heater off, let it cool, and top up the water container.
DIY Safe
W 18 H
Warning Air overheat condition
Either not all the warm air ducts are connected, the warm air outlets are blocked, or the circulated air intake is blocked
Check every warm air duct is properly connected to the heater and none are damaged or kinked, clear whatever's blocking the circulated air intake, and make sure the installation space has enough ventilation.
DIY Safe
W 402 H
Warning Air overheat condition
Warm air ducts disconnected, blocked, or circulated air intake obstructed
Check every warm air duct is properly connected to the heater and none are damaged or kinked, clear whatever's blocking the circulated air intake, and make sure the installation space has enough ventilation.
DIY Safe
W 24 H
Low voltage is imminent - battery voltage has dropped below 10.4V
Supply voltage has dropped below acceptable thresholds
Run the engine and check the power supply unit, and any other batteries, are working properly, charge the battery and check its contacts, and fit a new battery if it's old.
DIY Safe
E 29 H
The FrostControl heating element is drawing too much power
Electrical fault or short circuit in the FrostControl heating element
Must be replaced by an authorized service agent.
Professional Intervention Required
W 42 H
Window switch detects open window
Window above cowl is open while heater is operating
Close window above cowl.
DIY Safe
W 412 H
Window switch detects open window
Window above cowl is open
Close window above cowl.
DIY Safe
E 43 H
The 12V supply is faulty (overvoltage)
Excessive voltage supplied at the appliance 12 V input
Check the 12V supply reaching the appliance while under load - to test it, isolate the vehicle's own supply from both the solar system and the power supply unit.
DIY Safe
W 301 H
The 12V supply is faulty (overvoltage)
Voltage exceeds safe operating limits
Check the 12V supply reaching the appliance - to test it, isolate the vehicle's own supply from both the solar system and the power supply unit.
DIY Safe
E 540 H
The 12V supply is faulty (overvoltage)
Input voltage too high
Confirm there's a proper 12V supply under load at the appliance, and check for any stray AC voltage - to test it, isolate the vehicle's supply from both the solar system and the power supply unit.
DIY Safe
W 45 H
230 V power supply faulty
Mains supply issue or blown 230 V fuse or overheating protection triggered
Check the 230V supply reaching the appliance. Have a qualified person check the 230V fuse and replace it if needed, and reset the 230V overheating protection (see the Combi's own operating instructions).
DIY Check / Tech Fallback
W 407 H
230 V power supply faulty
Mains voltage missing or internal 230 V fuse blown
Check the 230V supply reaching the appliance. Have a qualified person check the 230V 10AF fuse and replace it if needed.
DIY Check / Tech Fallback
W 164 H
230 V power supply faulty
Mains supply fault or blown internal T10AH fuse
Check the 230V supply reaching the appliance and reset the 230V overheating protection. Have a qualified person check the 230V T10AH fuse and replace it if needed.
DIY Check / Tech Fallback
E 111 H
Fault in the electronics
Internal electronic error or unstable 12 V supply input under load
Check the 12V supply reaching the appliance while under load - to test it, isolate the vehicle's own supply from both the solar system and the power supply unit. Contact an authorised service agent if the problem persists.
DIY Check / Tech Fallback
E 112 H
The flame goes out or isn't detected, is unstable while running, or the gas supply cuts out
Interruption in gas supply or incorrect operating pressure
Check the gas supply is at the correct operating pressure.
DIY Safe
E 122 H
There isn't enough fuel - the tank level is low, has run dry, and/or the vehicle is on a slope
Fuel tank empty or vehicle tilted preventing fuel pickup
Refill the tank, then fill the fuel line as described under initial start-up in the operating instructions.
DIY Safe
W 255 H
The heater has no 12V supply, or the heater and control panel aren't connected to each other
Power cable disconnected or control panel bus communication fault
Check the 12V supply reaching the appliance - to test it, isolate the vehicle's own supply from both the solar system and the power supply unit. Also inspect the control panel's cable and confirm the heater and control panel are actually connected.
DIY Safe
W 302 H
The 12V supply is faulty (low voltage)
Battery voltage has dropped too low
Charge the battery and check its contacts, and fit a new one if it's old.
DIY Safe
W 160 H
The 12V supply is faulty (low voltage)
Low battery voltage or high resistance on supply line
Confirm there's a proper 12V supply under load at the appliance, charge the battery and check its contacts, fit a new battery if it's old, or switch off any high-draw appliances.
DIY Safe
E 541 H
The 12V supply is faulty (low voltage)
Input voltage too low
Confirm there's a proper 12V supply under load at the appliance, charge the battery and check its contacts, and fit a new battery if it's old.
DIY Safe
W 303 H
Low voltage risk - battery voltage has dropped below 10.4V
Battery state of charge is critically low
Run the engine and check the power supply unit, and any other batteries, are working properly, charge the battery and check its contacts, and fit a new battery if it's old.
DIY Safe
W 401 H
Hot water mode running with an empty water container
Water heating activated while container is empty
Switch the heater off, let it cool, and top up the water container.
DIY Safe
W 408 H
The gas supply has cut out while in mixed mode
Gas pressure drop or empty gas bottle while operating in mixed mode
Make sure the gas is arriving at the right operating pressure. Start up on gas only, acknowledge the fault, and then change to mixed mode.
DIY Safe
E 507 H
Gas supply interrupted
Gas supply failure or incorrect pressure
Check the gas supply is at the correct operating pressure.
DIY Safe
E 607 H
The heater's hit its maximum number of fault resets and is now locked out
More than 4 resets attempted within 15 minutes
Wait 15 minutes, then reset the fault.
DIY Safe
E 621 H
The room temperature sensor or its cable is faulty
Damaged room temperature sensor wire or loose plug connection
Check the room temperature sensor's cable and its plug connections, and fit a new sensor if it's faulty.
DIY Safe
E 624 H
The FrostControl heating element has short-circuited
Electrical short circuit in FrostControl heating element
Must be replaced by an authorized service agent.
Professional Intervention Required
E 132 H
The FrostControl heating element has short-circuited
Short circuit detected in FrostControl heating element circuit
Confirm there's a proper 12V supply under load at the appliance, and check for any stray AC voltage - to test it, isolate the vehicle's supply from both the solar system and the power supply unit. Contact an authorised service agent if the problem persists.
DIY Check / Tech Fallback
E 632 H
The 230V overheating protection has tripped
Mains heating element overheated
Reset the 230V overheating protection (see the Combi's own operating instructions).
DIY Safe
E 131 H
The heater and control panel aren't connected
Communication bus cable disconnected or damaged
Make sure the heater and control panel are properly connected to each other.
DIY Safe
W 150 H
Warm air temperature exceeded
Blocked air ducts or restricted circulated air intake
Check every warm air duct is properly connected to the heater and none are damaged or kinked, clear whatever's blocking the circulated air intake, and make sure the installation space has enough ventilation.
DIY Safe
W 151 H
Water too hot (heater mode)
Empty water container or restricted warm air/circulated air flow
Switch the heater off, let it cool, and top up the water container. Also check that every warm air duct is connected and unobstructed.
DIY Safe
E 152 H
Water too hot (hot water mode)
Water container empty during hot water operation
Switch the heater off, let it cool, and top up the water container.
DIY Safe
E 162 H
The window switch above the cowl is open
Safety switch triggered by open window near exhaust cowl
Close window above cowl.
DIY Safe
W 163 H
A temperature switch has tripped open
Appliance overheated due to restricted airflow
Let the heater cool down. Contact an authorised service agent if this keeps happening.
Professional Intervention Required
W 170 H
Imminent low voltage < 11.5 V
Supply voltage dropping toward threshold
Confirm there's a proper 12V supply under load at the appliance, charge the battery and check its contacts, and fit a new battery if it's old.
DIY Safe
W 423 H
Initial filling is needed (the fill function used at first start-up)
Boiler system unprimed during initial start-up
Trigger the initial fill by setting a heating request for 30°C.
DIY Safe
W 424 H
Initial filling active
Boiler is currently running initial priming cycle
Don't switch the heater off, or cut its power, while the initial fill is running.
DIY Safe
E 560 H
Heater will not start (locked after fifth error acknowledgment)
Repeated failed start attempts resulting in lockout
Check the fuel supply reaching the appliance. Contact an authorised service agent if the problem persists.
DIY Check / Tech Fallback
E 561 H
The heater won't restart - it's hit its maximum number of start attempts and locked out
Operating lock activated due to consecutive failed start attempts
Contact an authorized service agent.
Professional Intervention Required
E 565 H
The heater won't start; the flame keeps failing to be detected
Fuel delivery issue or air in fuel lines
Check the fuel supply reaching the appliance.
DIY Safe
E 8 A
The IR receiver is unplugged, or its cable is broken
Infrared receiver connection disconnected or damaged
Check the IR receiver's connection.
DIY Safe
E 17 A
The 230V supply has dipped
Mains supply voltage drop affecting air conditioning system
Check 230 V power supply.
DIY Safe