Bailey • Adamo • 2024
Complete guide — 97 diagnostic faults and 54 FAQs across 8 categories, assembled from every category document and cross-referenced part covering this exact edition.
Bailey230V/12V Electrical System (Jan 2024 Model Year, Autograph / Adamo / Alora / Endeavour)
Electrical1000 FAQs
230V/12V Electrical System (Jan 2024 Model Year, Autograph / Adamo / Alora / Endeavour)
ElectricalTechnical Specifications
Master Troubleshooting & Diagnostics Matrix
| Error Code / Indicator | Symptom / Meaning | Possible Cause | Step-by-Step DIY Fix | Suggested Actions |
|---|---|---|---|---|
N/A | A miniature circuit breaker (MCB) on the mains unit has tripped to the OFF position | A fault has developed in the 230V circuit protected by that MCB, or too many appliances are drawing power at once. | Eliminate the fault (or reduce the load) before re-setting — switch the MCB back to the ON position. | DIY Safe |
WhaleSpace and Water Heater — Seattle Control Panel
Heating System (Space/Water)4100 FAQs
Space and Water Heater — Seattle Control Panel
Heating System (Space/Water)Master Troubleshooting & Diagnostics Matrix
| Error Code / Indicator | Symptom / Meaning | Possible Cause | Step-by-Step DIY Fix | Suggested Actions |
|---|---|---|---|---|
1 | Seattle Control Panel prompt: Space Heater "Ignition Fault — Press Enter To Clear Lockout" / Water Heater "Ignition Fault — Press heater reset button to clear lockout" | No Flame Detected. | Check gas supply, making sure there is gas in the bottle and no blockage in the gas line. Ensure only propane is used if the temperature is below 5°C. Clear the lockout as described on the Seattle control panel. | DIY Safe |
2 | Seattle Control Panel prompt: Space Heater "Overheat Fault — Press Heater reset Button to clear lockout" / Water Heater "Overheat Fault — Press Heater Reset Button to clear lockout" | Overheat condition. | Check the air ducts and vents are not blocked or restricted. Wait at least 5 to 10 minutes to allow the Space Heater to cool before clearing the lockout as described on the Seattle control panel. | DIY Safe |
3 | Seattle Control Panel prompt: Space Heater "Voltage Fault — Press Enter to Clear Lockout" / Water Heater "Voltage Fault — Press Enter to Cycle Power" | Low/High Supply Voltage — Space Heater minimum operating voltage is 11.5V (max 15V); Water Heater minimum is 10V d.c. (max 15V d.c.), measured at the heater. | Check battery voltage is within the operating range. If in range, check connections between the heater and battery, and check the alternator or external battery charging. Clear the lockout as described on the Seattle control panel. | DIY Safe |
4 | Seattle Control Panel prompt: Space Heater "Air Pressure Fault — Press Enter to Clear Lockout" / Water Heater "Air Pressure Fault — Press Enter to Cycle Power" | Combustion Air Fault. | Check the combustion air inlet flue and exhaust flue for blockages. Clear the lockout as described on the Seattle control panel. | DIY Safe |
5 | Seattle Control Panel prompt: Space Heater "Miscellaneous Fault — Press Enter to Clear Lockout" / Water Heater "Miscellaneous Fault — Press Enter to Cycle Power" | Other / Internal Fault. | Clear the lockout as described on the Seattle control panel. If the fault recurs, seek service attention. | DIY Check / Tech Fallback |
BaileyGas Supply System (Jan 2024 Model Year, Autograph / Adamo / Alora / Endeavour)
Gas Regulator / Supply1030 FAQs
Gas Supply System (Jan 2024 Model Year, Autograph / Adamo / Alora / Endeavour)
Gas Regulator / SupplyMaster Troubleshooting & Diagnostics Matrix
| Error Code / Indicator | Symptom / Meaning | Possible Cause | Step-by-Step DIY Fix | Suggested Actions |
|---|---|---|---|---|
N/A | The crash sensor's yellow reset button hasn't been pressed, so the gas regulator isn't active | On a motorhome with a crash sensor, the gas regulator stays off until its yellow reset button is pressed. | If your gas hose has hose-rupture protection, give its green button a firm press for about 5 seconds. Then press the crash sensor's yellow reset button to switch the regulator on. | DIY Safe |
N/A | Smell of gas / suspected gas leak | Gas leak from a pipe joint, unlit appliance, or damaged component. | Cut the gas at the cylinder without delay. Put out every naked flame and other ignition source. Leave electrical switches alone. Make sure an unlit appliance isn't the source of the escape. Open every door and window to let the gas clear. Check pipe joints with a washing-up-liquid solution (never a naked flame for this). Evacuate if it's happening inside. Where the leak won't stop, take the cylinder somewhere safe and open, standing upright, well away from drains and anything that could ignite it, and get a competent service engineer on the phone. | Professional Intervention Required |
N/A | Taps feel too stiff to turn, or seem to be where a leak is coming from | Lack of lubrication or worn tap seals requiring specialist attention. | This needs a call to a specialist installer, who'll service the LPG taps with the correct special grease. | Professional Intervention Required |
N/A | Burner makes an unusual noise | Faulty regulator. | Have the regulator checked by a qualified person. | Professional Intervention Required |
AldeCompact 3020 PS
Heating System (Space/Water)1711135 FAQs
Compact 3020 PS
Heating System (Space/Water)Technical Specifications
Master Troubleshooting & Diagnostics Matrix
| Error Code / Indicator | Symptom / Meaning | Possible Cause | Step-by-Step DIY Fix | Suggested Actions |
|---|---|---|---|---|
Gas failure | The boiler won't fire up on gas. | Empty LPG bottle, closed main valve, unsuitable gas type for temperature, blown 12V fuse, low supply voltage below 11V, blocked or damaged exhaust hose, obstructed flue, incorrect gas pressure, or untripped/tripped crash sensor. | Check gas supply, open main valve, use propane for cold temperatures, inspect 12V fuse and supply voltage, ensure exhaust hose and flue are clear, verify gas pressure using the hob burners, and restart the boiler. If the fault persists, contact an authorised service agent. | DIY Check / Tech Fallback |
Connector failure | Communication error between boiler and panel. | Either the red cable (or its contacts) between boiler and panel has a fault, or something wired into the boiler's black contact - an AC unit or iNet box, say - has come loose. | Check the red connection cable and terminals between the boiler and panel, and inspect auxiliary cables connected to the black contact. If the issue remains unresolved, contact an authorised service agent. | DIY Check / Tech Fallback |
Heater not found | Connection error between boiler and control panel. | Problem with boiler printed circuit board or incompatible software versions. | Verify board compatibility (article number 3020 145 required). If the issue remains unresolved, contact an authorised service agent. | DIY Check / Tech Fallback |
Overheat glycol | Glycol temperature has overheated, often due to high power combined with air pockets. | Air pockets in the system, low glycol level in expansion vessel (below min mark when cold), broken circulation pump, or disconnected pump. | Bleed the heating system thoroughly, ensure fluid level is at least 1 cm above the min mark, and check circulation pump operation. Allow glycol temperature to drop below 50 °C, then disconnect and reconnect the 12V supply. | DIY Safe |
Overheat lockout | Boiler locked out due to prior over-temperature condition. | Temperature inside the boiler exceeded safe limits. | Disconnect and reconnect the 12V supply to the boiler once the temperature has dropped. | DIY Safe |
Overheat PCB | Overheating detected in the boiler unit or compartment. | Excessive ambient temperature or restricted airflow around the PCB. | Allow the boiler to cool down, then disconnect and reconnect the 12V supply. If the fault persists, contact an authorised service agent. | DIY Check / Tech Fallback |
Heater failure | Boiler operation halted due to hardware fault. | Damaged printed circuit board. | Disconnect and reconnect the 12V supply to the boiler. If the fault persists, contact an authorised service agent. | DIY Check / Tech Fallback |
Low battery voltage | Boiler stops operating due to insufficient supply voltage. | Vehicle battery voltage dropped below 10.8V. | Ensure the vehicle charging system provides proper voltage; the system will reset automatically when voltage reaches 11V. | DIY Safe |
Fan failure | Combustion fan fails to operate correctly. | Defective combustion fan or motor. | Contact an authorised service agent. | Professional Intervention Required |
Window open | Gas operation stops while electric operation continues. | A window switch indicates an open window near the wall flue. | Close the window near the wall flue to resume gas operation. | DIY Safe |
Panel failure | Control panel malfunctions. | Panel exposed to high humidity over an extended period. | Allow the panel to dry out completely and restart it. If the fault persists, contact an authorised service agent. | DIY Check / Tech Fallback |
Opt. dongle not found | Optional option card missing. | Previously identified option card has been disconnected or removed. | Reconnection required or uninstall accessories requiring the card. Cut 12V power, connect the card, and restore 12V power. If the fault persists, contact an authorised service agent. | DIY Check / Tech Fallback |
Load monitor not found | Load monitor missing or unresponsive. | Load monitor unplugged or defective. | Confirm the load monitor's properly wired in. Contact an authorised service agent if the fault's still there. | DIY Check / Tech Fallback |
Zone 1 sensor error / Zone 2 sensor error | Room temperature regulation fails for a specific zone. | Room sensor unplugged or defective sensor/cable. | Check that the sensor is plugged in and inspect the wiring. If the fault persists, contact an authorised service agent. | DIY Check / Tech Fallback |
Hot water sensor error | Hot water monitoring fails, though passive heating may still occur. | Hot water sensor unplugged or defective. | Check sensor connection. If the fault persists, contact an authorised service agent. | DIY Check / Tech Fallback |
Outdoor sensor error | Outdoor temperature display or control missing. | Outdoor temperature sensor unplugged or defective. | If it's been deliberately disconnected, press "dismiss" on the control panel. | DIY Safe |
CI-bus error | Communication failure on the yellow control panel connector. | High communication load or damaged wiring/connections to the vehicle master panel. | Check the cable, connections, and vehicle master panel. If the fault persists, contact an authorised service agent. | DIY Check / Tech Fallback |
iNet Connection error | Remote app integration lost. | iNet-box unplugged or defective. | If it's been deliberately disconnected, press "dismiss" on the control panel. | DIY Safe |
Remote Control error | External remote control unresponsive. | Remote control connected to JP3 on panel back is unplugged or defective. | Check cable and connections, or press "uninstall" on the control panel if intentionally removed. | DIY Safe |
Alde Voice not found | Voice control unit unresponsive. | Alde Voice Control main unit unplugged or defective. | If it's been deliberately disconnected, press "dismiss" on the control panel. | DIY Safe |
N/A | "No match Heater/Panel" message displayed | The control panel is incompatible with the boiler's PCB. | Check the control panel part number - control panel 3020-013 is for the 3020 A-series boiler, 3020-113 is for the 3020 HE-series boiler. | DIY Safe |
N/A | The system is completely dead / the control panel is blank | Blown fuse, insufficient 12V supply, or a loose cable connection. | Check the 20mm T3.15 amp glass fuse in the boiler (under the lid of the black plastic service hatch, in a green plastic fuse holder). Check the 12V supply to the boiler is above 12V. Check the 12V cable is plugged into both the boiler and the Alde control panel. | DIY Safe |
N/A | The boiler will not ignite on gas | Gas cylinder empty or not propane, or the boiler genuinely doesn't need gas at this time. | Check the gas cylinder is full and try a different gas cylinder, ensuring it is propane gas. Note: the system may not need to use gas heating if also using electric heating, and the boiler will not ignite if the fluids are already at operating temperature - neither of these is a fault. | DIY Safe |
N/A | The boiler will not heat on 230V electric | A 230V isolator switch is off, no 230V supply, or the fluids are already at operating temperature. | Check that any 230V isolator switches are on (they often have an LED indicator). Check the 230V supply to the vehicle. Note: the boiler will not heat further if the fluids are already at operating temperature - this is not a fault. | DIY Safe |
N/A | No hot water | 'Hot water ignore' or 'constant pumping' is activated on the Alde control panel, a conflicting setting is active, or a freshwater supply/pump issue. | Check that 'hot water ignore' and 'constant pumping' are not activated on the Alde control panel, check for other conflicting settings, and check the freshwater supply and water pump. | DIY Safe |
N/A | No central heating | Air in the system, low heat transfer fluid, circulation pump not responding, 'hot water boost' activated, obstructed vents, or degraded heat transfer fluid. | Bleed any air out of the system. Check the expansion tank's fluid level and the condition of the heat transfer fluid, and confirm the circulation pump's actually responding. Make sure "hot water boost" isn't switched on at the Alde control panel, try running gas and electric heating together, and check nothing's blocking the vents in the furniture. | DIY Safe |
N/A | "Panel failure 1" or "Panel failure 2" message displayed | Moisture is trapped in the control panel. | Remove the Alde control panel from the vehicle and air it in a warm, dry place overnight. | DIY Safe |
N/A | "Overheat red fail" or "Overheat blue fail" message displayed | Air in the system, low fluid level, or the circulation pump not responding. | Bleed any air out of the system, and check the expansion tank's fluid sits at least 1cm above the min mark once cool. Confirm the circulation pump's responding, then give the fluid 15 minutes to cool down. | DIY Safe |
N/A | "Overheat PCB" message displayed | The boiler's failsafe has triggered, typically due to low fluid level or restricted ventilation. | Check the expansion tank's fluid sits at least 1cm above the min mark when cool, and confirm the boiler compartment is properly ventilated with nothing blocking the vents - don't store anything in there. | DIY Safe |
Frequently Asked Questions
Q: My hot water has only been lukewarm since a service - why?
The technician may have left the circulation pump in continuous mode, which is meant for testing and stops the hot water cylinder getting enough heat. Resetting the Alde control panel to its factory defaults is usually the simplest fix - see your heater's operating instructions.
Q: Why does my Alde heating gurgle since it was serviced?
The circulation pump may still be on speed 5, which technicians use to push air out of the system. Turn it back down to speed 2-3 for a touring caravan or a B- or C-class motorhome, or to just below speed 4 for an A-class. If the heating fluid was replaced, there may also be air trapped in the system - see your heater's operating instructions.
Q: Can I run the central heating in winter with the fresh water drained?
Yes - use it exactly as you normally would. The hot water cylinder has no heating elements that could burn out, so it does no harm.
Q: Which antifreeze products does Alde approve?
In the UK, the products meeting Alde Approval 40X0 2024 are: Comma Xstream G40; Fuchs Fricofin DP; Volkswagen Group G12evo; and Alde's own Protective Premium in G12++ and G12evo versions. (Alde stopped selling its G13 products at the end of 2023.) All come ready-mixed with deionised water, are magenta, can be mixed with each other, and give frost protection down to -37°C plus 5 years' corrosion protection - but always check the label. North America has its own, chemically different, approved list.
Q: What should I top up my Alde heating fluid with?
Ideally the same antifreeze that's already in it. Magenta fluid almost certainly means an Alde-approved antifreeze, so top up with any approved product - they can all be mixed. If the fluid isn't magenta, the safest option is to add just one or two cups of deionised water - you lose a little frost, corrosion and bacteria protection, but mixing incompatible antifreezes risks worse damage.
Then have the fluid replaced with an Alde-approved antifreeze as soon as you reasonably can.
Q: How can I run my Alde heating as efficiently as possible?
Turn on all the electric and gas/diesel heating you have available - this actually uses less energy overall. Set the thermostat to a comfortable temperature rather than turning it right up when you feel cold, or you'll overshoot and end up opening windows; a jumper and a setting a couple of degrees lower saves more. If you don't need hot water overnight, tell the system not to heat it then.
Each season, bleed any air out of the heating fluid, and keep the vents at the top and bottom of cupboards and lockers clear.
Q: How much current does Alde heating draw?
On 12V DC, how much it takes from the leisure battery varies a lot. It peaks at ignition - about 2 A for gas heating, about 20 A for diesel. For off-grid planning, allow roughly 1 A while gas heating is running and about 4 A for diesel; switched off, the standby drain is around 80 mA. On mains: UK mains is nominally 230V but usually nearer 240V in practice, so expect roughly 4.8 A at 1 kW, 9.5 A at 2 kW and 14.3 A at 3 kW.
Q: How long should it take to warm up my caravan or motorhome?
That depends on how the vehicle is built and insulated, how cold it is outside, and how much power you can give the heater - more power means more heat. Most manufacturers now aim for around an hour from cold to a comfortable temperature.
Q: Can I leave the Alde heating on low to protect against frost?
You can heat the vehicle through the winter, though if nobody's staying in it you may decide it isn't worth the running cost. On mains hook-up at home, for example, you could set 10°C with 2 kW of electric heating. Check inside regularly for condensation and signs of rodents, and bear in mind some lockers and compartments probably won't be protected from frost.
Q: What routine maintenance does an Alde system need?
The heating fluid needs replacing once its corrosion protection runs out - Alde-approved antifreezes (magenta) last 5 years. Bleeding air from the fluid now and then improves efficiency. Each season, check the boiler flue: the hose should be secure and undamaged, and the outlet free of blockages. After 10 or more days staying in the vehicle, top up the boiler's air cushion.
Before any frost, drain the fresh water - and while you do, make sure the red breather valve hasn't scaled up. See your heater's operating instructions for details. An annual service may be a legal requirement, particularly if the vehicle serves as an annex to a house, is hired out, or is somewhere people work.
Q: In summer, can I have hot water without the heating coming on?
Set the room temperature on the control panel to around 15°C. In summer that's low enough that the central heating will rarely circulate, day or night, while hot water is not affected.
Q: Which fluid is my Alde system filled with?
That's down to whoever installed it - ideally an Alde-approved antifreeze, which is magenta. Alde advises against any antifreeze it hasn't approved.
Q: Where should the fluid sit in the expansion tank?
With the system cold, about 1 cm higher than the Min mark. As the fluid heats up it expands towards the Max mark.
Q: How much fluid does the central heating hold?
Roughly 10-15 litres in a touring caravan or a B- or C-class motorhome, and 20-25 litres in an A-class motorhome or a boat.
Q: What does the air cushion reminder mean?
After 10 days' use, the Alde system prompts you to top up the air cushion in the hot water cylinder, which keeps it running smoothly. If there's been water in the system: turn off the water pump, open all the taps and the shower fully, open the safety drain valve for 5-10 seconds and then close it, and refill the water system as usual. If the system has been dry, you can ignore the reminder.
Q: Why does my hot water come out scalding?
By law, stored hot water has to be kept hot enough to scald, to stop legionella - a potentially deadly bacteria - from growing. The Alde TMV3, an aftermarket accessory, limits the temperature of the water reaching your taps and shower.
Q: How much hot water can an Alde system supply?
Expect roughly a 4-5 minute shower every half-hour. The aftermarket Alde TMV3 can cut down on hot water wasted in the shower, and the Alde Flow gives continuous hot water - it can be retrofitted to any Alde-equipped vehicle from the 2018 model year on, and in the UK is sold only through Moosewerks.
Q: Can I put any fresh water into my Alde system?
Only water that's pleasant to drink. Some sites in Spain, Portugal and North Africa supply water heavy in bleach or salt, which corrodes stainless steel. Even if a tap is labelled as drinking water, don't put it through the Alde system if you couldn't bear to drink it - unless your vehicle has a reverse-osmosis water filter of at least 4 stages.
Q: Which sterilising and descaling products are safe for my Alde system?
Anything the label says is safe for a stainless steel water cylinder. Clean Tabs make a range of suitable products that are easy to find.
Q: Do I need to drain the fresh water for winter?
Yes. A vehicle can be designed to winterise itself, but very few on sale are.
Q: Can gas/diesel and electric heating run together?
Yes, and Alde recommends it. You can also set the system to favour one source over the other - for example, whichever is cheaper.
Q: How much gas does Alde heating use?
As a rough guide, a 6 kg propane cylinder should last a weekend of gas heating - though in freezing weather it will go considerably faster.
Q: Is propane or butane the right gas for Alde heating?
Propane. Butane isn't suitable below 13°C (BS 5482 Part 1).
Q: Can I use Autogas?
Yes.
Q: Is it safe to run gas heating while driving?
Alde advises against it. A crash sensor on the bulkhead regulator doesn't change the main risk: drive onto a fuel forecourt with the gas heater running and fumes could be pulled straight into its combustion chamber - effectively the same as carrying a lit camping stove across the forecourt. You'd need to pull over and switch gas heating off before every fuel stop, and forgetting just once could be disastrous.
Q: I've filled up with B10 diesel abroad by mistake - is that a problem?
No need to worry - it does no harm in the short term, though B10 or stronger biodiesel shortens the burner's life if used long-term. Carry on using the diesel heating normally until you can top up with at least half a tank of a compatible fuel, and try not to repeat it.
Q: Which diesel fuels can I use?
Alde's diesel models - the Compact 4000 D and the 4000 D Plus - run on B7 diesel (EN 590) and XTL diesel (EN 15940). If you use agricultural or marine diesel, HVO meeting EN 15940 is also compatible.
Q: Is it OK to run diesel heating while driving?
Alde doesn't recommend it. It's technically possible, but if you forget to switch the diesel heating off before stopping to refuel it won't go down well with staff or other customers - and fumes could be drawn straight into the combustion chamber. An Alde engine heat exchanger is the better option for heat on the move.
Q: Can my Alde system be converted from gas to diesel?
It depends on how much the boiler compartment and diesel tank need reworking. The Compact 4000 D isn't a straight swap for a Compact 3030, for instance, and not every diesel tank has an accessible sender or a spare fuel pick-up. The cost may well rule it out - Alde puts such a job at probably over £5,000. (Alde's own estimate, as given on its FAQ page in October 2026.)
Q: Can Alde provide diesel heating?
Yes - both the Compact 4000 D and the 4000 D Plus run on diesel. The Compact 3030 and 3030 Plus can't heat on diesel themselves, but an Alde-equipped motorhome can have the engine heat exchanger fitted to use the engine's waste heat.
Q: Can underfloor heating alone heat my vehicle?
No. Even caravans and motorhomes built to the top BS EN 1645 grade aren't insulated like a house, so underfloor heating would have to run too hot to walk on to warm the whole vehicle by itself.
Q: Is the central heating under pressure like a car's cooling system?
No - it's an open-vented system, which keeps the weight down and reduces the draw on the leisure battery.
Q: Can the electric heating run from the leisure battery alone?
No. The controls run on 12V DC, but the electric heating elements need 230V AC mains. Away from hook-up, you'll need to heat with gas or diesel. Run from a leisure battery, the electric heating would produce only around 9 W - roughly a tenth of the heat your own body gives off.
Q: Is Alde heating heavier than blown-air heating?
When filled, it's about 10 kg heavier than a combi heater. Separate space and water heaters are generally less powerful these days, so they aren't a like-for-like comparison.
Q: Can copper parts be used in an Alde heating circuit?
No. Alde Compact boilers have aluminium surfaces inside the glycol cylinder, and any copper particles circulating into it would set up galvanic corrosion.
Dometic10-Series
Fridge / Freezer344510 FAQs
10-Series
Fridge / FreezerTechnical Specifications
Reference
- Power icon (circle with vertical line) ON/OFF button
- Warning triangle Fault indication
- Battery icon Operating with DC power
- Flame icon Operating with gas
- Plug icon Operating with AC power
- Letter A Automatic mode
- Thermometer icon (segmented) Temperature indication
- MODE circle icon Energy selection button
- Thermometer icon (plain) Temperature selection button
Master Troubleshooting & Diagnostics Matrix
| Error Code / Indicator | Symptom / Meaning | Possible Cause | Step-by-Step DIY Fix | Suggested Actions |
|---|---|---|---|---|
N/A | [230V AC] The refrigerator does not work on AC | The AC supply's fuse has blown, or the vehicle isn't plugged into the mains | Check and replace the AC fuse, and ensure the vehicle is connected to a live mains supply. | DIY Safe |
N/A | [12V DC] The refrigerator does not work / no power on DC | The DC supply's fuse or the vehicle's fuse has blown, or the vehicle battery is flat | Check and replace the DC fuse and vehicle fuse, and check/charge the vehicle battery. | DIY Safe |
N/A | [Gas] The refrigerator does not work on gas | The gas cylinder has run out, the gas valve is shut, or there's air in the gas pipe | Check the gas cylinder level, open the gas valve, and bleed air from the supply line. | DIY Safe |
N/A | [Gas/Cooling] W01: Fridge-compartment temperature sensor faulty | Faulty or disconnected temperature sensor hardware/wiring | Check the sensor wiring and connection; replace the sensor if faulty. | DIY Check / Tech Fallback |
N/A | [230V AC] W05: No AC power, or the AC voltage is under 190V | Low mains voltage or the AC supply is disconnected | Check the AC connection and mains voltage. | DIY Safe |
N/A | [12V DC] W06: No DC power connected | Missing or disconnected 12V DC supply connection | Check the DC supply connection. | DIY Safe |
N/A | [12V DC] W11: DC overvoltage (above 16V) | Supply voltage exceeds safe operational thresholds | Check the vehicle's charging system for overvoltage. | DIY Safe |
N/A | [Mechanical/Water] W10: Door has been left open longer than 2 minutes | Refrigerator door left open, triggering a continuous warning beep | Close the refrigerator door. | DIY Safe |
N/A | [Gas] E03: Power module and display aren't communicating | Communication cable failure or module fault | Check the communication cable/connector between the power module and display. | DIY Safe |
N/A | [Gas] E07 / E08 / E09: No cooling capacity in gas, AC, or DC mode | The unit is operating at an unlevel angle, or there is a cooling unit failure | Check the appliance is level, then contact an authorised service agent if the fault persists. | DIY Check / Tech Fallback |
N/A | [Gas] E12 / E13: Gas valve check error or internal communication error | Gas valve fault or internal module communication failure | Contact an authorised service agent. | Professional Intervention Required |
N/A | [12V DC] E14: Battery pack charge too low in stand-alone gas mode | Depleted batteries in the standalone battery packs | Recharge or replace the standalone battery packs. | DIY Safe |
N/A | [Gas] E50: Gas locked out after 3 failed ignition attempts | Ignition not possible, or the gas cylinder is empty | Check the gas supply and reset the appliance to retry ignition. | DIY Safe |
N/A | Unburned/unburnt gas smell or exhaust gases entering the vehicle interior | Air inlet vent located too high (preventing complete evacuation of unburnt gas) or inadequate sealing between the refrigerator and the vehicle body | Check the position and sealing of the air inlet/outlet vents against the installation instructions. | DIY Safe |
N/A | Compressor does not run at low ambient temperatures (approx. below 0C) | External ventilation grilles left fully open (or not fully closed) when replacing an absorption unit with a compressor unit, or compressor compartment too cold | Adjust the external ventilation grilles per the compressor retrofit instructions. | DIY Safe |
N/A | Refrigerator does not cool sufficiently | Inadequate ventilation around the cooling unit, evaporator iced up, or temperature setting too high | Improve ventilation, defrost the evaporator if iced, and check the temperature setting. | DIY Safe |
N/A | [12V DC] Error code W02 / continuous LED: Defective temperature sensor in cooling compartment | Faulty or disconnected internal temperature sensor | Check the sensor wiring and connection; replace the sensor if faulty. | DIY Check / Tech Fallback |
N/A | [12V DC] Error code E03 / 3 light impulses: Communication error | Bus or display communication failure between internal modules | Check internal wiring/connectors between the display and control modules. | DIY Safe |
N/A | [12V DC] Error code W10 / continuous beep: Door open longer than 2 minutes | Refrigerator door left open | Close the refrigerator door. | DIY Safe |
N/A | [12V DC] Error code E32 / 2 light impulses: External fan overcurrent | Cooling fan drawing excessive current or jammed | Check the cooling fan for obstructions or mechanical failure; replace if faulty. | DIY Safe |
N/A | [12V DC] Error code E33 / 3 light impulses: Compressor fails to start | Compressor unit locked or electrical drive failure | Contact an authorised service agent. | Professional Intervention Required |
N/A | [12V DC] Error code E34 / 4 light impulses: Compressor overloaded | System blockage or excessive operating load | Check for blockages in the cooling system; contact an authorised service agent if the fault persists. | DIY Check / Tech Fallback |
N/A | [12V DC] Error code E35 / 5 light impulses: Compressor controller thermal fuse tripped | Overheating of the compressor electronics due to poor ventilation | Improve ventilation around the compressor electronics. | DIY Safe |
N/A | Ammonia smell, or cooling circuit damage/leak detected | Refrigerant/cooling circuit compromised, damaged, or ruptured | Stop using the appliance and contact an authorised service agent immediately - do not attempt to repair the cooling circuit yourself. | Professional Intervention Required |
N/A | Total/complete battery discharge when vehicle engine is off | DC heating element (12V) connected directly to the battery without an ignition-controlled relay | Ensure the DC heating element's supply line is wired through an ignition-controlled relay, not directly to the battery. | DIY Safe |
N/A | Device does not start, or system shuts down unexpectedly | Vehicle's battery management system shut down the device to protect the vehicle battery from over-discharge | Check the vehicle battery charge state and battery management system settings. | DIY Safe |
N/A | Excessive condensation inside the refrigerator | Frequent door opening, storing warm food, or a clogged/improperly routed condensation drain | Minimise door opening, allow food to cool before storing, and check the condensation drain is clear and correctly routed. | DIY Safe |
N/A | The fridge isn't cooling well enough | Inadequate ventilation to the unit | Make sure nothing is covering the ventilation grilles. | DIY Safe |
N/A | The fridge isn't cooling well enough | Thermostat setting is too low | Set thermostat to higher level | DIY Safe |
N/A | The fridge isn't cooling well enough | The condenser is heavily frosted | Confirm the refrigerator door is closing properly. | DIY Safe |
N/A | The fridge isn't cooling well enough | A lot of warm food has gone in over a short time. | Let warm food cool down before putting it in the fridge. | DIY Safe |
N/A | The fridge isn't cooling well enough | The appliance has only been running for a short while. | Give it around 4-5 hours, then see whether the fridge compartment has started cooling. | DIY Safe |
N/A | The fridge isn't cooling well enough | Ambient temperature is too high | Regularly remove ventilation grilles | DIY Safe |
N/A | The fridge won't cool while running on gas | Gas cylinder empty | Change the gas cylinder | DIY Safe |
N/A | The fridge won't cool while running on gas | Upstream shut-off device closed | Open shut-off valve | DIY Safe |
N/A | The fridge won't cool while running on gas | Air in the gas pipe | Switch the appliance off and start it again, repeating this 3 to 4 times if needed. | DIY Safe |
N/A | The fridge won't cool on 12V power | On-board fuse defective | Fit new fuse | DIY Safe |
N/A | The fridge won't cool on 12V power | On-board battery discharged | Check battery, charge it | DIY Safe |
N/A | The fridge won't cool on 12V power | Engine not running | Start engine | DIY Safe |
N/A | The fridge won't cool on 12V power | Heating element defective (refer to failure indication) | Get in touch with Dometic customer services. | Professional Intervention Required |
N/A | The fridge won't cool on 230V mains power | On-board fuse defective | Fit a new fuse | DIY Safe |
N/A | The fridge won't cool on 230V mains power | The vehicle isn't plugged in to a mains supply. | Plug the vehicle in to a mains supply. | DIY Safe |
N/A | The fridge won't cool on 230V mains power | Heating element defective (refer to failure indication) | Get in touch with Dometic customer services. | Professional Intervention Required |
Frequently Asked Questions
Q: What does the SN climate class on my Dometic RM fridge mean?
Climate class SN (which Dometic calls 'Extended Temperate') means the fridge is designed to work reliably when the air temperature is from +10°C up to +32°C (taken at the bottom vent grille, outside the vehicle).
Q: How well does an absorption fridge cool in hot weather?
In a hot summer the outside temperature often reaches about 32°C - the top of the fridge's rated range - and once it climbs higher, the temperature inside the fridge will inevitably rise. An absorption fridge needs a heat source to move its refrigerant around the cooling unit (which is why it can run on 12V, 230V or gas), so it has to get rid of the heat from its power source as well as the heat drawn out of the food compartment.
To help it in hot weather: park where the fridge vents get as much shade as possible during the day; unclip the outside vent grilles to improve airflow; and if you regularly travel somewhere hot, consider having a ventilator kit (a fan fitted behind the fridge) installed to boost the airflow - Dometic lists these among its accessories.
Q: What can replace my old Dometic RM fridge?
Dometic's 2023 'New for old - simply swap' guide covers both its absorption and compressor fridges, showing which current models replace older ones. It's available from the catalogues section of Dometic's website.
Q: My fridge won't work on mains (AC) power - what should I check?
Check the fuse in the mains supply and replace it if it has blown, and make sure the vehicle is actually plugged into a mains supply. If both are fine, the AC heating element may have failed - that needs an authorised Dometic service centre.
Q: My fridge won't work on 12V (DC) - what should I check?
Possible causes, and what to do: the vehicle's own fuse has blown - replace it (see the vehicle's handbook); the vehicle battery is flat - test it and recharge it; the ignition is off - switch it on. If the fuse in the fridge's DC cable has blown (the fuse on the relay) or the DC heating element has failed, contact an authorised Dometic service centre.
Q: My fridge won't work on gas - what should I check?
Check the gas cylinder isn't empty (change it if it is) and that the gas valve is turned on. If air has got into the gas pipe, turn the fridge off and on again, repeating this three or four times if needed; if a gas hob or cooker is fitted, switch that on, then try the fridge again if needed.
Q: Why is my fridge running on gas in automatic mode when I'm plugged into mains?
The mains voltage is too low. The fridge switches back to mains by itself once the supply voltage recovers.
Q: Why isn't my fridge getting cold enough?
Work through the likely causes: the cooling unit isn't getting enough air - make sure the outside vent grilles aren't blocked; the evaporator has iced up - check the door shuts properly and the seal is seated and undamaged, then defrost the fridge; the temperature setting is too warm - turn it to a colder setting; it's very hot outside - take the vent grille off for a while so hot air can escape faster; too much food, or too much warm food, went in at once - take some out, and let warm food cool before putting it back; the fridge was only switched on recently - give it four to five hours, then recheck the temperature.
Q: WARNING type fault messages
These codes apply to Dometic's 10-series fridges.
- W01: the temperature sensor in the fridge compartment is faulty - contact an authorised Dometic service centre.
- W05: no AC (mains) power, or the AC voltage is wrong - connect a supply, or choose another energy source such as gas.
- W06: no DC power - connect the fridge to DC power, or choose another energy source such as gas or mains AC.
W10 with a beep: the door has been left open longer than 2 minutes - close it. W11: DC overvoltage (above 16V) - reduce the DC supply voltage.
Q: ERROR type fault messages
ERROR-type faults on Dometic's 10-series fridges have to be reset by hand: on the RM10.5T, RMS10.5T and RMS10.5XT, hold the control knob in for 2 seconds; on the RM10.5S, RMS10.5S and RMS10.5XS, press and hold for 2 seconds. You'll hear a beep once the error is cleared.
- E03: the power module and display aren't communicating - contact an authorised Dometic service centre.
- E07, E08 and E09: no cooling in gas, AC (mains) or DC mode respectively - check the fridge (and the vehicle) is level and correct it if needed, then reset the error; if it comes back, contact Dometic customer service.
- E12 (gas valve test failed) and E13 (internal communication fault) both stop gas operation - reset the error, and contact customer service if it returns.
- E14: the battery packs that power it in stand-alone gas mode have run down - fit fresh batteries before resetting the error.
- E50: gas has locked out after 3 failed ignition attempts, usually because the gas cylinder is empty - change the cylinder, then reset the error.
- E51 (gas lock-out from an internal power-module fault), E52 (gas valve earth fault) and E53 (ignition electrode earth fault): reset the error, and contact customer service if it happens again.
BaileySmoke & Carbon Monoxide Alarms (Jan 2024 Model Year, Autograph / Adamo / Alora / Endeavour)
Smoke / CO Alarm1110 FAQs
Smoke & Carbon Monoxide Alarms (Jan 2024 Model Year, Autograph / Adamo / Alora / Endeavour)
Smoke / CO AlarmMaster Troubleshooting & Diagnostics Matrix
| Error Code / Indicator | Symptom / Meaning | Possible Cause | Step-by-Step DIY Fix | Suggested Actions |
|---|---|---|---|---|
N/A | The smoke alarm stays silent when you press its test button, or its status light isn't blinking on its usual 40-second cycle | Obvious damage, wrong or disconnected battery, or a dirty/blocked sensor. | Look the unit over for visible damage, confirm the right battery type is fitted with the cover off and the connection secure, and give it a gentle vacuum using a soft-brush attachment. Fit a new battery. If that doesn't fix it, don't try repairing the unit yourself — the smoke alarm needs replacing. | DIY Safe |
Recommended partAffiliate linksView partHideThis handbook specifies a 9V battery for the smoke alarm. 9V batteryDuracell Plus 9V Alkaline Batteries (2 Pack) 6LR61~£6.50 for 24.7★ (15,000+ ratings), dispatched/sold by Amazon View on Amazon → | ||||
N/A | CO alarm emits an audible 'chirp' once a minute | A fault with the battery, sensor, or circuitry, including a low battery. | Fit a fresh battery straight away for everyone's safety. If it keeps chirping even with new batteries and it's still under warranty, contact technical support for advice; once out of warranty, swap the detector for a new one. | DIY Check / Tech Fallback |
Recommended partsAffiliate linksView 4 optionsHideDoes the CO alarm itself need replacing? It may be a sealed unit with a built-in battery. FireAngel lists both of these alarms as suitable for caravans and motorhomes: The handbook doesn't name the battery type, so check your own alarm (and the expiry date on its back) before choosing. Sealed unit (10-year battery)FireAngel FA3322 Digital Carbon Monoxide Alarm~£37.994.6★ (700+ ratings), sold by FireAngel, dispatched by Amazon - battery sealed in for the alarm's life View on Amazon →Replaceable batteries (2x AA)FireAngel FA3313 Carbon Monoxide Alarm~£18.984.7★ (970+ ratings), dispatched/sold by Amazon - supplied with 2x AA batteries View on Amazon →Are the batteries replaceable in your CO alarm? Check which type it takes (look at the batteries fitted now), then choose the matching pack: AA batteriesDuracell Plus AA Alkaline Batteries (12 Pack) 1.5V, LR06~£9.00 for 124.7★ (71,000+ ratings), dispatched/sold by Amazon View on Amazon →9V batteryDuracell Plus 9V Alkaline Batteries (2 Pack) 6LR61~£6.50 for 24.7★ (15,000+ ratings), dispatched/sold by Amazon View on Amazon → | ||||
N/A | CO alarm sounds (loud audible signal, alarm LED flashing red once a second) | Carbon monoxide detected in the motorhome. | Stay calm and open every door and window for ventilation. Turn off and stop using any appliance that burns fuel. Get everyone out, leaving the motorhome's doors and windows open, and don't go back in until the alarm stops. Anyone showing signs of CO poisoning needs medical attention. Keep the motorhome out of use until your supplying retailer has fully serviced every appliance - a GAS SAFE registered installer must be the one to test the gas appliances. | Professional Intervention Required |
ThetfordC500 Series Cassette Toilet
Toilet3107 FAQs
C500 Series Cassette Toilet
ToiletTechnical Specifications
Master Troubleshooting & Diagnostics Matrix
| Error Code / Indicator | Symptom / Meaning | Possible Cause | Step-by-Step DIY Fix | Suggested Actions |
|---|---|---|---|---|
N/A | Waste-holding tank is difficult to remove | Waste-holding tank is too full | Empty the waste-holding tank | DIY Safe |
N/A | Waste-holding tank is difficult to insert | Mechanism is blocked or out of position | Ensure the mechanism is in the correct position and that slide is closed | DIY Safe |
N/A | Waste-holding tank leaks | Seal is dry or damaged | Lubricate the seal with approved lubricant or replace it | DIY Safe |
N/A | Flush does not work | Fuse is blown or power supply interrupted | Check the power supply and fuse. If the issue remains unresolved, contact an authorised service agent | DIY Check / Tech Fallback |
Frequently Asked Questions
Q: How to use the Thetford cassette toilet?
A Thetford cassette toilet is a lightweight and compact toilet designed for use in caravans and motorhomes. The waste is stored in a removable cassette tank, which can be easily emptied into a designated waste disposal point . Watch the video for full instructions
Q: Is it possible to replace my cassette toilet?
Yes. In most situations it is possible to replace the toilet. Contact your dealer or Thetford Service Centre for the possibilities.
Q: How do Thetford toilet additives compare to regular household cleaning products used at home when looking at their environmental impact?
A mobile toilet in your motorhome is not like a regular toilet at home. A mobile toilet additive has functionalities that are not required in your toilet at home. Our products are technologically advanced, applying the latest developments in tailor-made ingredients for mobile toilet applications, and are specifically intended for effective treatment of toilet waste in a small, confined space.
We believe in offering the best performing products for mobile and portable toilets. For that reason, we continuously develop our products to improve their overall performance, whilst respecting the environment. The ingredients we use in our products comply with the biodegradability requirements for detergents in the EU, and we are constantly looking for opportunities to improve product performance at all levels.
Household cleaning products are not designed to meet the requirements of a mobile toilet. Using them for a purpose for which they were not intended or treating wastewater from a mobile toilet with unsuitable products may negatively impact the environment or consumer health. So, never use a cleaning product for a purpose for which it was not designed.
In conclusion, compared to regular household cleaning products, Thetford toilet additives are a more environmentally friendly option for the treatment of waste and prevention of odour and other problems in a mobile toilet system
Q: What is the best maintenance for my toilet?
Empty the waste-holding tank (toilet waste tank) when it is full or starts to smell (4 to 5 days for Thetford Blue products, 3 to 4 days for Thetford Green products), use Thetford Aqua Soft quick dissolving toilet paper to prevent clogging. Regularly clean the outside of the toilet with Thetford Bathroom Cleaner and clean the toilet bowl with Thetford Toilet Bowl Cleaner when necessary.
Finally, clean the waste-holding tank and grey water tank (tank that collects waste water from sink and shower) with Duo Tank Cleaner Concentrated 2-3 times a year to keep all moving parts inside the tank at peak operational level and to prevent odour formation during winter storage.
Q: How often do I have to replace the lip seal?
Depending on user behaviour, we recommend replacement after 4-6 years.
Q: How to keep your toilet clean
Thetford offers a pleasantly-scented toilet fluid for the flush-water tank and a variety of waste-holding tank products. Aqua Rinse Concentrated keeps the flush water fresh, ensures a smooth flush and leaves a protective layer. All products for the waste-holding tank suppress unpleasant odours, stimulate the breakdown of waste, reduce the formation of gas, protect moving parts and help keep your waste-holding tank fresh and clean.
Q: I always clean my tank(s) with domestic cleaners. It gets clean as well. Why should I use Duo Tank Cleaner Concentrated?
First of all, in our tanks we talk about specific kind of dirt, not directly comparable with the home situation. And, it’s not only about curing, but also about caring. Duo Tank Cleaner Concentrated cleans and cares, without damaging the material of or components in your tanks.
BaileyDigital TV Antenna System (Jan 2024 Model Year, Autograph / Adamo / Alora / Endeavour)
TV / Aerial / Satellite3101 FAQ
Digital TV Antenna System (Jan 2024 Model Year, Autograph / Adamo / Alora / Endeavour)
TV / Aerial / SatelliteMaster Troubleshooting & Diagnostics Matrix
| Error Code / Indicator | Symptom / Meaning | Possible Cause | Step-by-Step DIY Fix | Suggested Actions |
|---|---|---|---|---|
N/A | LED on the amplifier does not light | — | First confirm the unit is getting power. Next check the polarity is right. Grade UK Ltd can help further if that doesn't solve it. | DIY Check / Tech Fallback |
N/A | Very poor reception: no picture or sound at all, the TV freezing, heavy pixelation, breakup, and the picture dropping out. | — | Confirm the amplifier gain is turned fully clockwise to maximum. Confirm the antenna is actually pointed at the transmitter. Confirm the antenna's polarity (horizontal or vertical) is set correctly. Try bypassing the amplifier using 'Short Hook-up: Test 1'. Whichever of these you change, re-tune the TV afterwards. | DIY Safe |
N/A | Signal too strong: expect pixelation, breakup, and dropouts in the picture. | — | Turn the amplifier gain down (anti-clockwise). Point the antenna away from the transmitter. Re-tune the TV after making either change. | DIY Safe |
N/A | Signal far too strong: no picture or sound, the TV freezing, heavy pixelation, breakup, and the picture dropping out. | — | Point the antenna in the opposite direction from the transmitter, turn the amplifier off, and set its gain control fully clockwise to maximum. Re-tune the TV after making either change. | DIY Safe |
Frequently Asked Questions
Q: How do I set up and operate the TV antenna on my Bailey?
Start by working out roughly where the nearest transmitter is and whether it's broadcasting a horizontal or vertical signal - your site operator or a look at neighbouring pitches' aerials will usually tell you. Loosen off the mast's locking collar, wind the antenna up, and turn the mast until it's facing the transmitter (there's an H/V mark on the base of the mast that shows you which way is the back).
If you need vertical polarisation, twist the winder anticlockwise to tip the antenna over by 90 degrees, but don't force it. With the aerial in position, power up the amplifier - its LED should light - and wind the gain control fully clockwise to its maximum setting. From there, retune your TV to find the strongest signal, nudging the mast's direction if needed for a cleaner picture, then lock everything in place by doing the locking collar back up.
If you're getting a strong signal and the picture's breaking up, the gain can be wound back down (anticlockwise) - it turns through a full 270 degrees between its minimum and maximum settings.
BaileyWater System (Jan 2024 Model Year, Autograph / Adamo / Alora / Endeavour)
Water System Component4001 FAQ
Water System (Jan 2024 Model Year, Autograph / Adamo / Alora / Endeavour)
Water System ComponentMaster Troubleshooting & Diagnostics Matrix
| Error Code / Indicator | Symptom / Meaning | Possible Cause | Step-by-Step DIY Fix | Suggested Actions |
|---|---|---|---|---|
N/A | Pump keeps running non-stop, even when every tap is shut | Voltage has dropped well below its level at the last adjustment, or the water container has run dry | Re-adjust switch or refill container. | DIY Safe |
N/A | Pump won't run at all | Blown fuse, faulty connections, or excessive running | Check fuses and connections. If caused by excessive running, replace the pump and re-adjust the pressure switch. | DIY Safe |
Recommended partsAffiliate linksView 2 optionsHideCheck whether the blown fuse is a standard or a mini blade fuse (mini ones are roughly half the size), then choose the matching kit: The handbook doesn't say which fuse rating or size is fitted - match the rating printed on the blown fuse. If it's a glass or ceramic cartridge fuse rather than a blade, these kits won't fit. Standard blade fusesCar Fuse Kit - 60pc Assorted Blade Fuses (5A-30A) with Storage Case and Fuse Puller~£5.994.5★ (1,500+ ratings), sold by KANGRUI, dispatched by Amazon - includes 15A blade fuses plus a puller and storage case View on Amazon →Mini blade fusesNilight 120pc Mini Blade Fuse Assortment (5A-30A, ATM/APM) with Fuse Puller~£5.244.5★ (2,500+ ratings), sold by Amazon - includes 15A mini blade fuses View on Amazon → | ||||
N/A | Pump switches on and off in a repeating pattern (tap flow pulses, or the water temperature cycles hot-cold-hot-cold instead of staying steady) | Voltage has risen above its level at the last adjustment | Re-set the pressure switch. A Whale Surge Damper (WS7205) can be fitted if the issue keeps happening. | DIY Safe |
N/A | Pump is very noisy but pumps no water (it's air locked) | The pump has become air locked - fighting to push air out while drawing water in - most often right after refilling the water container | Disconnect the pump from its socket so it floods, then plug it back in. When refilling, the order matters: disconnect first, lower the pump into the container, and only then reconnect it. | DIY Safe |
Frequently Asked Questions
Q: How do I drain down and winterize the water system on my motorhome?
Open every tap in the vehicle and push the mixer lever handles up to the central position so both hot and cold sides can empty out. Take the shower head off by hand, give it a shake to clear any trapped water, and keep it somewhere dry. Then open the drain valve - on Advance/Alliance models this sits beside the on-board tank, on Autograph models it's next to the boiler - and switch the pump on to push the rest of the water out of the system.
For a proper full drain, it's worth doing the fresh and waste tanks manually too: there's an inspection cap on top of the tank giving access to a drain plug, and for the waste tank, move the vehicle over to a proper disposal point and open the drain tap behind the rear wheel to let it empty. Leaving any water in over a freezing night is enough to cause serious, permanent damage to the system, and frost damage isn't something your warranty will cover - so always finish with the manual draining step to be sure everything's properly empty, not just what the pump alone can get.