Q: How do I wind the wind-out awning in and out?

Locate the socket on the left side of the awning case and insert the winding handle, then turn clockwise - the fabric starts to unroll after a couple of turns. Once it's out to about a metre, stop and lower the support legs, adjusting their length until they reach the ground, then keep unrolling until the awning is fully extended.

Adjust the legs' height so the fabric sits taut and rain can run off, then pull the handle back out. It's worth pegging the legs down too. To put it away, reverse the process - wind anti-clockwise until it snaps back into the box, then keep turning slowly until the handle stops, which locks it shut.

Dometic

HBG / CE99 / MO / PI Series

Hob / Cooker
4040 FAQs
View full Dometic page →

Technical Specifications

ElectricalConnection voltage 12 V DC (models with electronic ignition only), 1 A fuse
Gas Or PressureGas categories: I3B/P(30) (Propane G31 / Butane G30 at 30 mbar) and I3+ (Propane G31 at 37 mbar / Butane G30 at 28-30 mbar). Steel pipe Ø 8 x 1 mm gas-tight welded.
Capacities DimensionsVentilation openings cross-section minimum 150 cm². Burner S power: 1.0 kW (Injector 0.50 - 0.54 mm). Burner M power: 1.6 kW (Injector 0.65 mm). Burner L power: 1.8 kW (Injector 0.67 mm). Distance to range hood: min 650 mm.

Master Troubleshooting & Diagnostics Matrix

Error Code / IndicatorSymptom / MeaningPossible CauseStep-by-Step DIY FixSuggested Actions
N/A
No spark when spark ignition button is pressed.
Spark ignition is defective or gas supply valve is closed.Light the burner by hand and get an authorised service agent to fix it. Open the gas supply valve if it's closed.Professional Intervention Required
N/A
Burner does not ignite. Spark ignition is working.
Could be blocked burner ports, the control knob not set right, or not held down long enough.Take the burner out, clean it, and refit it. Turn the control knob to somewhere between Low and High flame, and hold it in for 5 seconds so the flame safeguard can engage.DIY Safe
N/A
The burner goes out as soon as you let go of the control knob.
Either a faulty connection, or the flame safeguard itself has failed.Get an authorised service agent to carry out repairs.Professional Intervention Required
N/A
The flame pattern is uneven, or lifts slightly.
Burner ports are blocked.Take the burner out, clean it, and refit it.DIY Safe
N/A
The flame's too high even on the lowest setting.
Could be the regulator's set wrong, the gas supply pressure's too high, or the wrong injection valve is fitted.Get an authorised service agent to carry out repairs.Professional Intervention Required
N/A
The flame's too low even on the highest setting.
Could be the regulator's set wrong, the gas supply pressure's too low, the wrong injection valve fitted, or a blocked injector/gas tube.Get an authorised service agent to carry out repairs.Professional Intervention Required
N/A
Low heat, slow cooking.
Unsuitable cookware is being used on the selected burners.Use suitable cookware (S: 10-16 cm, M: 12-18 cm, L: 16-22 cm diameter).DIY Safe
N/A
The control knobs or the worktop around them are getting too hot.
The cookware isn't sitting properly on the burner.Ensure the cookware is centered on the burner.DIY Safe
Auto-Trail

Electrical System (V-Line SE, 2026 Model Year)

Electrical
1002 FAQs
View official manual on manufacturer's site ↗

Master Troubleshooting & Diagnostics Matrix

Error Code / IndicatorSymptom / MeaningPossible CauseStep-by-Step DIY FixSuggested Actions
Red LED below fuse
Red LED below fuses (2-9) on the PSU is illuminated
The respective fuse has blown while the circuit was active.Investigate the fault, then replace the blown fuse with a new one of the exact same amperage rating. Never use a higher rating.DIY Safe

Frequently Asked Questions

Q: How do I activate silent mode on the Sargent PX310 battery charger?

Hold the button down for 3 seconds to turn silent mode on - it quietens the fan down overnight by capping output at 5A.

Q: Which fuse or MCB protects which circuit, and what rating should I use to replace one?

On the PSU (fuses 2 to 9 each show a red LED beneath them once blown, for whichever circuit is actually in use): Fuse 1 (25A, white) - Charger; Fuse 2 (10A, red) - 12V Sockets; Fuse 3 (10A, red) - Main Lighting; Fuse 4 (7.5A, brown) - Auxiliary/Awning Lighting; Fuse 5 (7.5A, brown) - Filler Pump; Fuse 6 (7.5A, brown) - Pump; Fuse 7 (7.5A, brown) - Dimmable Lighting; Fuse 8 (7.5A, brown) - Permanent (Unswitched); Fuse 9 (10A, red) - Compressor Fridge (Permanent Switched).

MCBs: MCB 1 (16A) - Heating System; MCB 2 (10A) - 230V Sockets; MCB 3 (10A) - Fridge/Charger. Always fit a replacement fuse rated the same as the original - never a higher one, since that risks damage to the wiring harness. If a new fuse blows again straight away, don't just keep swapping it out - get the underlying fault checked and speak to your dealer.

Sargent

AC-DC Battery Chargers

Standalone Battery Charger (Accessory)
5005 FAQs
View full Sargent page →

Master Troubleshooting & Diagnostics Matrix

Error Code / IndicatorSymptom / MeaningPossible CauseStep-by-Step DIY FixSuggested Actions
N/A
The electrical system shuts down by itself randomly.
Overvoltage - the Sargent system shuts down as soon as it detects more than 15V, usually because of a faulty solar regulator or a mains charger faultTo check whether the solar regulator's at fault, see if the random shutdowns only happen during sunny daytime hours when the regulator's actually active - disconnecting the solar input, or covering the panel, is a good way to test this. You could also measure the regulator's output voltage directly, though that reading can jump around depending on cloud cover. For the charger, a fixed-voltage type should never read above 13.8V; if you've got a PX300 fitted, its product page has a downloadable attachment for checking it's working correctly.DIY Safe
N/A
Battery is overheating and showing symptoms of being overcharged.
A failed cell within the lead-acid battery (turning it effectively into a 10V battery, causing it to draw more current and overheat under normal charge voltage).Check the battery itself for a failed cell first. If you suspect the charger rather than the battery, see the separate troubleshooting for a PX300 that isn't working correctly.DIY Safe
N/A
Lithium battery has entered Deep Sleep mode (DSLP) with State of Charge reduced to 0% and output switched off.
The battery State of Charge has reduced to 0%.Get the battery back on charge as soon as you can, since leaving it will shorten its lifespan and hurt performance. If it's gone into Deep Sleep, the Sargent PX310 charger's own 'lithium wakeup' feature may be able to rouse it and start charging normally - or you can briefly apply a fixed 12-15V across the terminals yourself.DIY Safe
N/A
Lithium battery has gone into Under Voltage Protection (UVP) after a cell dropped below 2.5V (or the terminals fell below 10V), cutting off output entirely
Critical low internal voltage of battery cells due to deep discharge.Get it back on charge immediately - a fixed-voltage charger will bring the cells back up to the level at which they'll switch back on (2.8V per cell, or 11.2V total across four cells). Depending on how deeply discharged it is, this can take up to 30 minutes.DIY Safe
N/A
PX300 charger isn’t working correctly
—Head to the PX300's product page, download the attachment linked there, and follow its instructions to check the charger's output voltages and confirm it's working properly.DIY Safe

Frequently Asked Questions

Q: What happens when the Sargent control system detects the battery State of Charge falls to 15%?

First, an alert appears on the control panel's screen, warning that the battery needs recharging.

Q: And if it's still not recharged and drops further, down to 5%?

The system alerts again, then switches off every circuit it controls to stop further discharge - though anything wired directly to the battery, bypassing the control system, will keep drawing current regardless.

Q: How can I extend the lifespan of a Sargent lithium battery?

Steer clear of frequent deep discharges, and try to keep it sitting at a partial charge - ideally somewhere between 40% and 80% - rather than running it right down. Don't treat Under Voltage Protection (UVP) kicking in as your cue to recharge; by then it's already past where you want to be.

Q: Can I fit a Lithium battery to my system?

Most Sargent systems use a PX300 or PF200 battery charger. If yours has a different charger fitted, check with that charger's own manufacturer for Lithium compatibility. The PX300's charging profile suits many leisure-industry Lithium batteries that have their own internal Battery Management System (BMS) - its charging profile and voltages are available as a downloadable attachment on the PX300's own product page, though you'll still need to confirm suitability directly with your chosen battery's manufacturer.

Systems that use a PX300 include the EC800, EC700, EC600, EC500, EC400 series, EC400+ and EC328. If your system doesn't have a PX300, its charger will run a fixed 13.8V, which generally isn't suitable for fully charging a Lithium battery - and switching to Lithium may also mean you need a DC-DC charger to keep the charging current within limits.

Q: Can I fit a different make of AGM battery?

We don't endorse any particular make or model, but the PX300 charger (fitted across the EC400/EC400+, EC500, EC600, EC700, EC800 and EC328 systems) suits the great majority of good-quality AGM batteries sold in the UK. Its charge profile is included in the instruction manual attached to its product page - if you're at all unsure whether a battery is compatible, check with that battery's own distributor or manufacturer first.

Sargent

Modular Series Systems

Battery Charger / Power Management
0003 FAQs
View full Sargent page →

Technical Specifications

Operating Voltage12V / 230V
Fuse Ratings8 x blade fuses (up to 25A total output), Leisure & Vehicle battery inputs protected by 20A fuses, Battery Charger input up to 25A
Display4" colour touchscreen (EC940), 7" colour touchscreen (EC970)

Frequently Asked Questions

Q: How do I set up a second lithium battery from Sargent's LB series?

Installation and wiring: wire the extra LB series battery into the vehicle's 12V system first, and connect its magnetic communication cable to the Sargent Control System's CAN bus. Before paralleling two batteries, make sure both are fully charged to the same voltage, to avoid a big rush of current between them the moment they're connected.

Changing the battery address: adding a second battery in parallel means changing its communication address from the default '1' to '2', so both can talk to the system at once - only have the battery you're changing connected via its comms cable while you do this (the steps are the same on the 4" EC940 and 7" EC970 screens).

Configuring single or dual batteries: the display needs the Sargent Lithium+ battery switched on in the ADVANCED SETUP menu first, or it won't communicate with it - choose Lithium+ for a single battery, or Lithium+ x2 for a dual setup.

Information displays: once configured, extra screens appear in the Control Panel's POWER menu. On the EC940's 4" display, a dual setup's two batteries are combined into one figure (two 70Ah batteries show as 140Ah total); on the EC970's 7" display, tapping the battery symbol switches between Battery 1 and Battery 2's individual readings.

Q: How do I set up ultrasonic water sensors?

Installation and wiring: mount each sensor on the tank's top surface, close to the middle, to avoid reflections off the tank wall and reduce variation when parked on a slope. Fit a side-mounted overflow too, so a sensor doesn't end up sitting underwater after filling and skewing its readings - and note the sensor isn't suitable for tanks with a sloped or irregular base, which will also throw off readings.

Configuring the sensors: enable the Sargent Ultrasonic Water Sensors in the ADVANCED SETUP menu first so the display can communicate with them, and enable the relevant tank too for its level to actually show - any tank not configured for ultrasonic sensing is assumed to have a traditional rod/stud sensor instead.

First-time calibration: the sensor automatically starts calibrating its tank depth the first time it gets 12V power, so make sure it's fitted and the tank is empty beforehand for an accurate result. Once calibrated, it sends regular readings (roughly every 5 seconds for fresh tanks, 10 for waste) - and since it can't read fluid closer than 30mm to its own face, the 100% level gets set 30mm below the measured tank depth. Re-calibration can be triggered any time from the Advanced Setup menu, either automatically (again, with the tank empty first) or manually if you'd rather enter the tank depth yourself.

Information displays: once set up, each sensor's data appears under the WATER menu, reading in 1% steps rather than the 25% steps a rod/stud sensor uses. The EC940's 4" display shows fresh and waste levels on separate screens (use '>' to switch), while the EC970's 7" display shows both together on one screen.

Q: How do I configure the modular system for a Webasto Thermo Top EVO?

To link a Webasto Thermo Top EVO heater to the Sargent MC100 Control Unit (for control via the EC970 panel), you'll need two extra Sargent parts: the Fan Adaptor PCB (17464) and Fan PCB harness (89003-24). Wire it up following the diagram for the Webasto-to-Sargent connections - note that harness cable colours in the standard Modular System kit (K970A) may differ on OEM installations.

For setup help with the heater itself, contact Webasto directly or check their portal at https://my.webasto.net/en/. On the Sargent side, enable the Webasto Thermo Top from the ADVANCED SETUP menu first, which then adds a 'Heating' option to the home screen for controlling it - the Help button in the top-right corner explains each individual control.

Auto-Trail

Gas Supply System (V-Line SE, 2026 Model Year)

Gas Regulator / Supply
2000 FAQs
View official manual on manufacturer's site ↗

Master Troubleshooting & Diagnostics Matrix

Error Code / IndicatorSymptom / MeaningPossible CauseStep-by-Step DIY FixSuggested Actions
Flame lifting away from burner
On a gas appliance, the flame lifts clear of the burner instead of sitting on it.
Pressure is too high.Go back over the regulator, gas cylinders, and pipework, and make any adjustments needed.DIY Safe
Yellow flame
Gas appliance producing a yellow flame causing soot
Pressure is too low.Go back over the regulator, gas cylinders, and pipework, and make any adjustments needed.DIY Safe
Whale

SL3501, SL3511, SL5501, SL5511, SL5601, SL5611, SL6501, SL6511

Space Heater
0613 FAQs
View full Whale page →

Technical Specifications

Operating Voltage10.5 – 15.9 V DC
Power Consumption7.9A (Nominal)
Gas Or PressureLPG: Butane / Propane 30 mbar - CAT I3B/P (30)
Fuse Ratings10A inline

Master Troubleshooting & Diagnostics Matrix

Error Code / IndicatorSymptom / MeaningPossible CauseStep-by-Step DIY FixSuggested Actions
1
Inadequate gas supply
Insufficient gas pressure or lack of gas supplyCheck gas supply, ensure 30mbar LPG is available, and proceed to step 4 to clear the lockout. If the issue remains unresolved, contact an authorized service agent.DIY Check / Tech Fallback
2
Overheat
Heater exceeded normal operating temperature due to restricted airflowMake sure the air vents and ducts aren't restricted, then give the heater 10 minutes to cool before moving to step 4 to clear the lockout. Contact an authorised service agent if the fault persists.DIY Check / Tech Fallback
3
Inadequate supply voltage
The DC supply voltage has drifted outside the heater's 10.5-15.9V operating range (it won't run at all below 10.1V).Verify supply voltage is between 10.5 and 15.9V DC, and proceed to step 4 to clear the lockout. If the issue remains unresolved, contact an authorized service agent.DIY Check / Tech Fallback
4
Flue blockage
Obstruction in the exhaust flue or combustion inletCheck flues for blockages, clear any obstructions such as snow or debris, and proceed to step 4 to clear the lockout. If the issue remains unresolved, contact an authorized service agent.DIY Check / Tech Fallback
5
Internal fault
Internal system error or component failureCall Whale Support (+44 (0)345 9090 911) (in Europe, use the enclosed Webasto Service details instead) and move to step 4. This fault needs a repair or replacement carried out by an authorised service agent.Professional Intervention Required
6
Control panel fault
Communication error or temporary glitch in the control panelPower off the unit, power on the unit, and proceed to step 4 to clear the lockout. If the issue remains unresolved, contact an authorized service agent.DIY Check / Tech Fallback
7
Multiple faults
Simultaneous or sequential system errors triggeredPower off the heater, check heater for recurring faults, power on, and proceed to step 4 to clear the lockout. If the issue remains unresolved, contact an authorized service agent.DIY Check / Tech Fallback

Frequently Asked Questions

Q: Can I fit a Heat Air heater myself?

If you're technically minded, yes - each Heat Air kit includes a detailed step-by-step installation guide. Otherwise, a local motorhome workshop should be able to fit it for you. Whoever fits it, a qualified gas engineer has to certify any gas work to BS EN 1949-2011.

Q: Which Heat Air model should I choose?

The models differ in heat output and fuel type, with options for both campervans and panel-van conversions - broadly, the bigger the vehicle, the more output you'll want. Gas-only suits off-grid touring; if you mostly stay on sites with hook-up, the gas-and-electric version adds 3kW of electric heating.

Q: Will Heat Air work when I'm off-grid?

Yes. Every Heat Air model can run on gas, and on its low gas setting it draws very little from the battery - as little as 0.6 A.

Auto-Trail

Smoke & CO Alarms (V-Line SE, 2026 Model Year)

Smoke / CO Alarm
3000 FAQs
View official manual on manufacturer's site ↗

Master Troubleshooting & Diagnostics Matrix

Error Code / IndicatorSymptom / MeaningPossible CauseStep-by-Step DIY FixSuggested Actions
Short beep once a minute
The smoke alarm gives a brief beep every minute.
The battery is worn out and needs replacing - the low-voltage warning will keep sounding for about seven days.Replace the battery immediately.DIY Safe
Recommended partsAffiliate linksView 2 optionsHide

Check which battery your smoke alarm takes (look at the battery fitted now), then choose the matching one:

The handbook says the smoke alarm is battery-operated but doesn't name the battery type, so check yours before ordering.

9V batteryDuracell Plus 9V Alkaline Batteries (2 Pack) 6LR61~£6.50 for 24.7★ (15,000+ ratings), dispatched/sold by Amazon
View on Amazon →
AA batteriesDuracell Plus AA Alkaline Batteries (12 Pack) 1.5V, LR06~£9.00 for 124.7★ (71,000+ ratings), dispatched/sold by Amazon
View on Amazon →
LED doesn't blink once a minute
The smoke alarm's LED doesn't blink once a minute as it normally would.
The battery is completely flat.Replace the battery immediately.DIY Safe
Recommended partsAffiliate linksView 2 optionsHide

Check which battery your smoke alarm takes (look at the battery fitted now), then choose the matching one:

The handbook says the smoke alarm is battery-operated but doesn't name the battery type, so check yours before ordering.

9V batteryDuracell Plus 9V Alkaline Batteries (2 Pack) 6LR61~£6.50 for 24.7★ (15,000+ ratings), dispatched/sold by Amazon
View on Amazon →
AA batteriesDuracell Plus AA Alkaline Batteries (12 Pack) 1.5V, LR06~£9.00 for 124.7★ (71,000+ ratings), dispatched/sold by Amazon
View on Amazon →
One chirp a minute
The carbon monoxide detector gives one audible chirp every minute, and can continue doing so for up to 30 days.
Settings of the sensor and circuitry are incorrect or the batteries have become low.Check/replace batteries or unit if required.DIY Safe
Recommended partsAffiliate linksView 4 optionsHide

Does the CO alarm itself need replacing? It may be a sealed unit with a built-in battery. FireAngel lists both of these alarms as suitable for caravans and motorhomes:

The handbook doesn't name the alarm model or its battery type, so check your own alarm (and the expiry date on its back) before choosing.

Sealed unit (10-year battery)FireAngel FA3322 Digital Carbon Monoxide Alarm~£37.994.6★ (700+ ratings), sold by FireAngel, dispatched by Amazon - battery sealed in for the alarm's life
View on Amazon →
Replaceable batteries (2x AA)FireAngel FA3313 Carbon Monoxide Alarm~£18.984.7★ (970+ ratings), dispatched/sold by Amazon - supplied with 2x AA batteries
View on Amazon →

Are the batteries replaceable in your CO alarm? Check which type it takes (look at the batteries fitted now), then choose the matching pack:

AA batteriesDuracell Plus AA Alkaline Batteries (12 Pack) 1.5V, LR06~£9.00 for 124.7★ (71,000+ ratings), dispatched/sold by Amazon
View on Amazon →
9V batteryDuracell Plus 9V Alkaline Batteries (2 Pack) 6LR61~£6.50 for 24.7★ (15,000+ ratings), dispatched/sold by Amazon
View on Amazon →
Auto-Trail

Toilets & Sanitation (V-Line SE, 2026 Model Year)

Toilet
0001 FAQ
View official manual on manufacturer's site ↗

Frequently Asked Questions

Q: How do I prepare the Thetford cassette waste-holding tank before using the toilet?

Take the waste-holding tank out through the service door, stand it up so the pour-out spout faces upward, then take the cap off. Add the recommended amount of Thetford waste-holding tank additive plus roughly 3 litres of water so the bottom is covered, refit the cap, and slot the tank back into place.

Auto-Trail

TV & Antenna (V-Line SE, 2026 Model Year)

TV / Aerial / Satellite
0001 FAQ
View official manual on manufacturer's site ↗

Frequently Asked Questions

Q: How do I tune the Avtex television the very first time I switch it on?

Use the direction arrows to pick the on-screen (OSD) language for your display, then choose 'Auto Search' and hit 'OK'.

Auto-Trail

Water System (V-Line SE, 2026 Model Year)

Water System Component
1001 FAQ
View official manual on manufacturer's site ↗

Master Troubleshooting & Diagnostics Matrix

Error Code / IndicatorSymptom / MeaningPossible CauseStep-by-Step DIY FixSuggested Actions
Aerated water
Aerated water coming from a tap
There may be a leak on the pump's suction side.Look for a leak where the pump draws water in and repair as needed.DIY Safe

Frequently Asked Questions

Q: How do I drain down the water system for winter or storage?

Open the fresh water tank's drain valve, then the wastewater tank's (into a suitable container), then leave every tap inside the vehicle open (mixer taps set to their central position). There's also an internal drain valve that clears the water heater and its own pipework - open that too, give the vehicle five minutes to finish draining, then briefly run the pump to clear any water left in it. Empty the cassette toilet too.

Whale

Expanse

Water Heater
5111 FAQ
View full Whale page →

Technical Specifications

Operating Voltage12V DC / 230V AC
Gas Or Pressure28-30 mbar Butane or Propane
Fuse Ratings5A inline (12V) / 10A (230V)

Master Troubleshooting & Diagnostics Matrix

Error Code / IndicatorSymptom / MeaningPossible CauseStep-by-Step DIY FixSuggested Actions
N/A
Damage found on the appliance or electrical supply cord prior to or during installation
Component or power cord damaged during transit or handlingDon't install the appliance. A damaged electrical supply cord must only be replaced by the manufacturer, one of its service agents, or another similarly qualified person, to avoid a hazard - contact an authorised service agent or Whale Support straight away.Professional Intervention Required
N/A
Water heater control panel shows 'No Flame Detected' (number-of-bars-lit fault indicator)
No gas supply, empty gas bottle, blockage in the gas line, using butane below 5C, or a blocked combustion air inlet/exhaust flue.Check the gas supply, making sure there is gas in the bottle and no blockage in the gas line. At temperatures below 5C, use propane gas rather than butane. Check the combustion air inlet flue and exhaust flue for blockages. Clear the lockout by pressing the water heat setting button and the plus (+) symbol button simultaneously for 3 seconds.DIY Safe
N/A
Water heater control panel shows 'Overheat' (number-of-bars-lit fault indicator)
No water in the appliance, or the water heater has not been given time to cool.Check that there is water in the appliance. Whale recommends waiting at least 5 to 10 minutes to allow the water heater to cool, then clear the lockout by pressing the water heat setting button and the plus (+) symbol button simultaneously for 3 seconds.DIY Safe
N/A
Water heater control panel shows 'Low/High Supply Voltage' (number-of-bars-lit fault indicator)
Supply voltage at the water heater is outside the 10V-15V d.c. operating range.Check battery voltage. If between 10V d.c. and 15V d.c., check connections between the water heater and battery. Check the alternator or external battery charging. Clear the lockout by pressing the water heat setting button and the plus (+) symbol button simultaneously for 3 seconds.DIY Safe
N/A
Water heater control panel shows 'Air Proving' (number-of-bars-lit fault indicator)
Combustion air inlet flue or exhaust flue blocked.Check the combustion air inlet flue and exhaust flue for blockages. Clear the lockout by pressing the water heat setting button and the plus (+) symbol button simultaneously for 3 seconds.DIY Safe
N/A
Water heater control panel shows 'Other/Internal Fault' (number-of-bars-lit fault indicator)
Internal fault.Attempt to clear the lockout by pressing the water heat setting button and the plus (+) symbol button simultaneously for 3 seconds. If this fails, contact Whale Support on +44 (0)845 217 2933.DIY Check / Tech Fallback
N/A
Water heater control panel shows 'General Fault' (number-of-bars-lit fault indicator)
Two faults have occurred at the same time, or at least five lockout-clearing attempts have been unsuccessful.Turn off power to the water heater, check the water heater for faults, then turn power back on and clear the lockout by pressing the water heat setting button and the plus (+) symbol button simultaneously for 3 seconds.DIY Safe

Frequently Asked Questions

Q: Does Whale make a thermostatic mixing valve?

Yes, product code is WX1599.