Use the dropdowns below to set a start point, then browse the whole collection with the ‹ › arrows.
Auto-Sleepers • Berkshire • 2009
Complete guide — 120 diagnostic faults and 21 FAQs across 9 categories, assembled from every category document and cross-referenced part covering this exact edition.
Auto-SleepersChassis & Running Gear (Berkshire & Hampshire, 2009 Model Year)
Chassis / Towing Control1001 FAQ
Chassis & Running Gear (Berkshire & Hampshire, 2009 Model Year)
Chassis / Towing ControlMaster Troubleshooting & Diagnostics Matrix
| Error Code / Indicator | Symptom / Meaning | Possible Cause | Step-by-Step DIY Fix | Suggested Actions |
|---|---|---|---|---|
N/A | The power-operated rear step is still out when the ignition gets switched on. | — | A buzzer behind the dashboard sounds the moment the ignition's switched on, and keeps going until the step's been fully retracted. | DIY Safe |
Frequently Asked Questions
Q: How does the electric rear step work?
It's operated by the switch next to the entrance door - hold it until the step is fully extended; don't try to mount it while it's still moving or only partway out, since the lock won't be engaged and you risk damaging the motor. If you drive off with it left out, a buzzer behind the dashboard sounds once the ignition's on and the step retracts automatically.
Dirt or frost can stop it working properly, so keep the moving parts clean and free of ice.
Auto-SleepersCooking Equipment (Berkshire & Hampshire, 2009 Model Year)
Cooking2020 FAQs
Cooking Equipment (Berkshire & Hampshire, 2009 Model Year)
CookingMaster Troubleshooting & Diagnostics Matrix
| Error Code / Indicator | Symptom / Meaning | Possible Cause | Step-by-Step DIY Fix | Suggested Actions |
|---|---|---|---|---|
N/A | Cooker Hotplate not heating up | No power | Check MCB is on | DIY Safe |
N/A | Cooker ignition not operating | Fuse 11 blown | Track down the fault and fit a replacement fuse of the identical rating. | DIY Safe |
Recommended partsAffiliate linksView 2 optionsHideCheck whether the blown fuse is a standard or a mini blade fuse (mini ones are roughly half the size), then choose the matching kit: This fault doesn't say which fuse rating has blown, only to replace it like-for-like. Both kits cover the common ratings (5A-30A) - match the rating printed on the blown fuse. Standard blade fusesCar Fuse Kit - 60pc Assorted Blade Fuses (5A-30A) with Storage Case and Fuse Puller~£5.994.5★ (1,500+ ratings), sold by KANGRUI, dispatched by Amazon - includes 15A blade fuses plus a puller and storage case View on Amazon →Mini blade fusesNilight 120pc Mini Blade Fuse Assortment (5A-30A, ATM/APM) with Fuse Puller~£5.244.5★ (2,500+ ratings), sold by Amazon - includes 15A mini blade fuses View on Amazon → | ||||
N/A | Cooker ignition not operating | Spark unit fault | Refer to dealer | Professional Intervention Required |
N/A | Cooker ignition not operating | Fault on cooker unit | Refer to dealer | Professional Intervention Required |
DaewooKOR6L1B Microwave Oven (as fitted to Auto-Sleepers motorhomes)
Microwave1100 FAQs
KOR6L1B Microwave Oven (as fitted to Auto-Sleepers motorhomes)
MicrowaveTechnical Specifications
Master Troubleshooting & Diagnostics Matrix
| Error Code / Indicator | Symptom / Meaning | Possible Cause | Step-by-Step DIY Fix | Suggested Actions |
|---|---|---|---|---|
N/A | The microwave oven doesn't work | Not connected to mains, door not firmly closed, cooking time not set, or a blown fuse/tripped circuit breaker. | Make sure the power cord is plugged in securely, the door is shut firmly, and a cooking time has actually been set. Also check for a blown fuse or a tripped circuit breaker on the supply. | DIY Safe |
N/A | Sparking inside the microwave cavity | Metal cookware or metal-trimmed dishes are being used, or a metal skewer/foil is touching the inside walls of the oven. | Check you're not using any metal containers or metal-trimmed dishes, and that no metal skewer or foil is touching the oven's interior walls. Contact the service station if it keeps happening. | DIY Check / Tech Fallback |
Auto-SleepersElectrical System (Berkshire & Hampshire, 2009 Model Year)
Electrical33460 FAQs
Electrical System (Berkshire & Hampshire, 2009 Model Year)
ElectricalMaster Troubleshooting & Diagnostics Matrix
| Error Code / Indicator | Symptom / Meaning | Possible Cause | Step-by-Step DIY Fix | Suggested Actions |
|---|---|---|---|---|
N/A | Habitation 12V does not operate | Main 20A fuse blown | Check/Replace | DIY Safe |
N/A | Habitation 12V does not operate | Battery discharged | Recharge | DIY Safe |
N/A | Habitation 12V does not operate | The control panel's power switch is set to off. | Switch to on | DIY Safe |
N/A | Habitation 12V does not operate | Vehicle ignition 'on' | Switch 'off' ignition | DIY Safe |
N/A | Habitation battery not charging | Main 20A fuse blown | Check/Replace | DIY Safe |
N/A | Habitation battery not charging | Relay fault | Refer to dealer | Professional Intervention Required |
N/A | Habitation battery not charging | Contacts dirty/loose on battery terminals | Clean and check for tightness | DIY Safe |
N/A | Habitation battery not charging | Poor earthing | Check earthing to chassis point | DIY Safe |
N/A | Battery does not hold its charge | Failed battery | Check cells with hydrometer, change electrolyte if necessary | Professional Intervention Required |
N/A | Battery does not hold its charge | Current being drawn when not in use | Check all appliances are off | DIY Safe |
N/A | Battery discharges over a short time with appliances operating | Poor battery cell condition | Check cells with hydrometer | DIY Safe |
N/A | Battery discharges over a short time with appliances operating | Failed battery | Change battery | DIY Safe |
N/A | Battery discharges over a short time with appliances operating | Battery not fully charged | Fully recharge battery | DIY Safe |
N/A | One or more 12V appliances have no power reaching them. | Circuit fuse blown | Track down the fault and fit a replacement fuse of the identical rating. | DIY Safe |
Recommended partsAffiliate linksView 2 optionsHideCheck whether the blown fuse is a standard or a mini blade fuse (mini ones are roughly half the size), then choose the matching kit: This fault doesn't say which fuse rating has blown, only to replace it like-for-like. Both kits cover the common ratings (5A-30A) - match the rating printed on the blown fuse. Standard blade fusesCar Fuse Kit - 60pc Assorted Blade Fuses (5A-30A) with Storage Case and Fuse Puller~£5.994.5★ (1,500+ ratings), sold by KANGRUI, dispatched by Amazon - includes 15A blade fuses plus a puller and storage case View on Amazon →Mini blade fusesNilight 120pc Mini Blade Fuse Assortment (5A-30A, ATM/APM) with Fuse Puller~£5.244.5★ (2,500+ ratings), sold by Amazon - includes 15A mini blade fuses View on Amazon → | ||||
N/A | No power on 12V socket outlet | Fuse 9 blown | Track down the fault and fit a replacement fuse of the identical rating. | DIY Safe |
Recommended partsAffiliate linksView 2 optionsHideCheck whether the blown fuse is a standard or a mini blade fuse (mini ones are roughly half the size), then choose the matching kit: This fault doesn't say which fuse rating has blown, only to replace it like-for-like. Both kits cover the common ratings (5A-30A) - match the rating printed on the blown fuse. Standard blade fusesCar Fuse Kit - 60pc Assorted Blade Fuses (5A-30A) with Storage Case and Fuse Puller~£5.994.5★ (1,500+ ratings), sold by KANGRUI, dispatched by Amazon - includes 15A blade fuses plus a puller and storage case View on Amazon →Mini blade fusesNilight 120pc Mini Blade Fuse Assortment (5A-30A, ATM/APM) with Fuse Puller~£5.244.5★ (2,500+ ratings), sold by Amazon - includes 15A mini blade fuses View on Amazon → | ||||
N/A | No power on 12V socket outlet | 12V plug incorrectly connected/wired | Check plug | DIY Safe |
N/A | 230V system inoperative | No site power | Check site supply | DIY Safe |
N/A | 230V system inoperative | RCD/MCB switches tripped out | Reset circuit breakers | DIY Safe |
N/A | RCD/MCB keeps tripping out | Fault on 230V supply | Check supply including polarity | DIY Safe |
N/A | RCD/MCB keeps tripping out | Faulty appliance | Switch every appliance off, reset the circuit breakers, then switch appliances back on one at a time until the fault reappears - that identifies and isolates the faulty one. | DIY Safe |
N/A | RCD/MCB keeps tripping out | Overload on current consumption by appliance | 10A maximum available; do not use appliance | Professional Intervention Required |
N/A | Battery charger does not operate | Charger switched off | Switch on at control box/check MCB is on | DIY Safe |
N/A | Reverse polarity warning light is illuminated on the PSU | — | This light is designed to catch a reversed/crossed live and neutral supply on UK-wired sites - if it comes on, suspect a fault with the site's own supply, or its connecting cable (outside the UK it can light up with no actual fault present, so check with the site warden). It can also light up quite normally when running from certain generators, since some centre-tap their earth connection rather than earthing the neutral directly, leaving both conductors roughly 110V above earth - usually still safe to keep using in that case, but check the generator's own handbook. | DIY Check / Tech Fallback |
N/A | Control panel has no display | — | Check the batteries, switch the charger on at the PSU, and confirm the mains supply is connected. Check the connecting lead at both the PSU and the control panel. If that doesn't resolve it, contact your dealer. | DIY Check / Tech Fallback |
N/A | 12V power switches itself off | — | This is usually the battery-save feature stepping in to protect the vehicle and/or leisure battery, or the engine having been started (in which case equipment gets disconnected automatically to meet EMC requirements). | DIY Safe |
N/A | Control panel display is corrupt or behaves erratically | — | The control panel's own software may have crashed. Reboot it either by switching off the PSU charger and pulling fuses 1 and 2 (the two 20A fuses covering the leisure and vehicle batteries), waiting 30 seconds, then refitting them and switching the charger back on - or by removing the control panel's bezel (pull down at the bottom centre), unplugging its multi-way connector, waiting 30 seconds, then reconnecting and reassembling. | DIY Safe |
N/A | Control panel contrast is poor | — | Remove the control panel as for a reboot, but leave it plugged in, then carefully adjust the small contrast preset on the back using a jeweller's screwdriver. | DIY Safe |
N/A | Control panel's current reading is incorrect | — | Recalibrate the current sensor: with the charger switched off and the panel powered down (no LEDs lit), scroll the display to the battery current reading, then hold the select (left arrow) button until 'calibrating...' appears - keep holding until the reading reappears, then release. Repeat the whole process once more to store the new setting. | DIY Safe |
N/A | No 230V output from the PSU | The lead linking the site supply to the vehicle isn't plugged in | Check the lead is connected properly - also check the socket where it plugs into the underside of the PSU. | DIY Safe |
N/A | No 230V output from the PSU | RCD switched off | Reset the RCD. | DIY Safe |
N/A | No 230V output from the PSU | RCD not operating correctly | Check the supply polarity; if the RCD keeps failing, contact your dealer, as there's likely an equipment or wiring fault. | DIY Check / Tech Fallback |
N/A | No 230V output from the PSU | MCB switched off | Reset the MCB by switching it off (down) then back on (up); if it keeps tripping, contact your dealer, as there's likely an equipment or wiring fault. | DIY Check / Tech Fallback |
N/A | No 230V output from the PSU | No or deficient supply from the site | Contact the site warden for assistance. | Professional Intervention Required |
N/A | No 230V output from the PSU | Some other fault | Contact your dealer. | Professional Intervention Required |
N/A | No 12 volt output from the PSU | No 230V supply | Work through the 230V checks above first. | DIY Safe |
N/A | No 12 volt output from the PSU | Charger not switched on | Turn the charger switch on - it will illuminate when active. | DIY Safe |
N/A | No 12 volt output from the PSU | Battery not connected and/or not charged | Fit a charged battery. | DIY Safe |
Recommended partAffiliate linksView partHideOnly if your leisure battery needs replacing - check the size, type and terminal layout of the one fitted now, and that your charger supports it, before ordering: Leisure batteries vary by vehicle (size, capacity and type - lead-acid, AGM, EFB or lithium). This is a widely used 100Ah EFB battery, not a documented exact match for your vehicle. Leisure battery (100Ah EFB)Yuasa L36-EFB 12V 100Ah Leisure Battery~£1384.3★ (119 ratings), sold by Amazon - established battery brand View on Amazon → | ||||
N/A | No 12 volt output from the PSU | Power switch on the control panel not switched on | Turn the power on at the control panel. | DIY Safe |
N/A | No 12 volt output from the PSU | Battery flat, or its fuse blown | Recharge the battery, check the fuses, and confirm charging voltage is actually present at the battery. | DIY Safe |
N/A | No 12 volt output from the PSU | A fuse has blown | Make sure none of the fuses have blown and each one matches the rating shown on the fuse table. | DIY Safe |
N/A | No 12 volt output from the PSU | Equipment switched off or unplugged | Check the equipment itself is switched on and properly connected to the 12V supply. | DIY Safe |
N/A | No 12 volt output from the PSU | PSU has overheated and shut down automatically | Reduce the load on the system and let the PSU cool down - it will restart on its own once it has. | DIY Safe |
N/A | No 12 volt output from the PSU | Some other fault | Contact your dealer. | Professional Intervention Required |
Auto-SleepersGas Supply System (Berkshire & Hampshire, 2009 Model Year)
Gas Regulator / Supply5040 FAQs
Gas Supply System (Berkshire & Hampshire, 2009 Model Year)
Gas Regulator / SupplyMaster Troubleshooting & Diagnostics Matrix
| Error Code / Indicator | Symptom / Meaning | Possible Cause | Step-by-Step DIY Fix | Suggested Actions |
|---|---|---|---|---|
N/A | Appliance will not light | No gas | Swap in a replacement cylinder, confirm it's turned on, and check the isolation valve is open. | DIY Safe |
N/A | Appliance will not light | Low battery (auto ignition) | Charge battery | DIY Safe |
N/A | Appliance lights but goes out immediately the FSD override is released | Flame supervision device (FSD) is not functioning correctly | Refer to dealer | Professional Intervention Required |
N/A | Odour | Gas leak | Shut down the gas supply at the cylinder without delay, and leave the system alone until it's been properly fixed. Should a cylinder appear to be leaking, relocate it - if it's safe to do so - well clear of anything that could ignite it, then get in touch with the site warden and/or your local gas supplier. | Professional Intervention Required |
N/A | Yellow flame | There isn't enough primary air reaching the burner - note that a little yellow tipping on the flame is normal and not a fault. | Refer to dealer | Professional Intervention Required |
N/A | Orange flame | Dust or dirt particles in the mixing tube are being carried through the burner ports. | Reduce the level of dust in the surrounding air. | DIY Safe |
N/A | Orange flame | Burner ports partially blocked | Refer to dealer | Professional Intervention Required |
N/A | Floating flame | Lack of secondary air | Make sure every vent is clear, including the vehicle's air inlet. | DIY Safe |
N/A | Floating flame | Blocked retention ports | Make sure the retention ports aren't blocked; on an oven, also confirm the flue way isn't obstructed. | DIY Safe |
Auto-SleepersHeating (Berkshire & Hampshire, 2009 Model Year)
Heating System (Space/Water)6020 FAQs
Heating (Berkshire & Hampshire, 2009 Model Year)
Heating System (Space/Water)Master Troubleshooting & Diagnostics Matrix
| Error Code / Indicator | Symptom / Meaning | Possible Cause | Step-by-Step DIY Fix | Suggested Actions |
|---|---|---|---|---|
N/A | Water heater does not operate on 230V | No power | Switch on isolator switch/check MCB is on | DIY Safe |
N/A | Water heater does not operate on 230V | Overtemperature trip activated | Reset the thermal cut-out, following the operating instructions. | DIY Safe |
N/A | Water Heater not operating/cuts out | Fuse 11 blown | Track down the fault and fit a replacement fuse of the identical rating. | DIY Safe |
Recommended partsAffiliate linksView 2 optionsHideCheck whether the blown fuse is a standard or a mini blade fuse (mini ones are roughly half the size), then choose the matching kit: This fault doesn't say which fuse rating has blown, only to replace it like-for-like. Both kits cover the common ratings (5A-30A) - match the rating printed on the blown fuse. Standard blade fusesCar Fuse Kit - 60pc Assorted Blade Fuses (5A-30A) with Storage Case and Fuse Puller~£5.994.5★ (1,500+ ratings), sold by KANGRUI, dispatched by Amazon - includes 15A blade fuses plus a puller and storage case View on Amazon →Mini blade fusesNilight 120pc Mini Blade Fuse Assortment (5A-30A, ATM/APM) with Fuse Puller~£5.244.5★ (2,500+ ratings), sold by Amazon - includes 15A mini blade fuses View on Amazon → | ||||
N/A | Water Heater not operating/cuts out | Low battery charge | Recharge battery | DIY Safe |
N/A | Water Heater not operating/cuts out | Unit fault | Refer to dealer | Professional Intervention Required |
N/A | No hot water (mains system) | Water heater tripped | Check and press re-set button | DIY Safe |
N/A | No hot water (gas system) | Gas module not lighting | Refer to dealer | Professional Intervention Required |
N/A | No hot water (gas system) | Igniter not working | Check 12V switched on | DIY Safe |
TrumaTrumatic S 3002 P / S 3002 / S 5002
Space Heater9105 FAQs
Trumatic S 3002 P / S 3002 / S 5002
Space HeaterTechnical Specifications
Master Troubleshooting & Diagnostics Matrix
| Error Code / Indicator | Symptom / Meaning | Possible Cause | Step-by-Step DIY Fix | Suggested Actions |
|---|---|---|---|---|
No ignition sparks or sparks occurring slower than once per second | Depleted or dead battery in the automatic ignition unit, or bad connection. | — | Replace the battery (Mignon LR 6, AA, AM 3) with a temperature-resistant (+70 °C), leak-proof type with the heater switched off. | DIY Safe |
Gas line filled with air after cylinder change | Air trapped in the gas supply line preventing immediate combustion. | — | Hold the control knob fully depressed and actuate the igniter continuously for up to 2 minutes until the flame ignites. | DIY Safe |
Flame fails to light or goes out repeatedly | Faulty regulator, closed valve, or air in lines. | — | Wait at least 2 minutes before attempting a new ignition to prevent flashbacks. Verify gas supply and regulator condition. | DIY Safe |
No ignition sparking heard / monitor lamp 'e' not flashing | The battery on the auto ignitor is depleted or needs replacement. | — | Replace the battery with a temperature-resistant (+70 °C), leakproof Mignon battery (LR 6, AA, AM 3) with correct polarity. | DIY Safe |
Flame goes out repeatedly in windy conditions or winter | Extreme wind conditions or snow buildup are affecting the cowl. | — | Clear snow from the cowl and consider using a cowl extension such as AKV or SKV. | DIY Safe |
Gas line is air-filled during initial start | Air trapped in the gas supply line delays it lighting straight away. | — | Hold the control knob down and constantly actuate the igniter for up to two minutes until the gas is available and the flame burns. | DIY Safe |
N/A | Blown air not working | Supply fuse blown. | Replace the fuse. | DIY Safe |
N/A | Blown air running slowly | Hair or dust in the fan wheel, affecting the balance of the blown-air system. | Electrically isolate and clear with a brush; close/open to re-balance the system. | DIY Safe |
N/A | Blown air only blowing on one leg of the ducting system | A pipe is disconnected, or the fan paddle is not correctly positioned. | Check all pipe connections. Check the position of the paddle to ensure air flows in one direction. | DIY Safe |
N/A | Heater goes out when a door is slammed | The flue is disconnected or damaged. | Turn the heater off immediately and seek service attention. | DIY Check / Tech Fallback |
Frequently Asked Questions
Q: Can the Trumatic S 5002 be installed in motorhomes?
No, the Trumatic S 5002 heating system must not be installed in motorhomes. Only the Trumatic S 3002 (P) is permitted in motorhomes.
Q: What should I do if there is a gas leak or smell of gas?
Put out all naked flames right away, don't smoke, switch off every appliance, close the gas cylinder, open the windows and doors, avoid electrical switches, and have an expert inspect the whole system.
Q: How do I replace the battery in the automatic igniter?
Remove the heater casing, slide the battery compartment cover upwards, replace the battery observing correct plus/minus polarity, and close the compartment. Use only temperature-resistant (+70 °C) leak-proof Mignon LR 6, AA, AM 3 batteries.
Q: If the heater fails to start, how long should I wait before trying to re-ignite?
Wait at least 2 minutes before re-igniting, to avoid any risk of deflagration or misfiring.
Q: What type of battery should be used for the automatic ignition device?
Only use temperature-resistant (+70°C), leak-proof Mignon batteries (LR 6, AA, AM 3).
TrumaUltraheat electric additional heater
Space Heater Accessory / Booster3105 FAQs
Ultraheat electric additional heater
Space Heater Accessory / BoosterTechnical Specifications
Master Troubleshooting & Diagnostics Matrix
| Error Code / Indicator | Symptom / Meaning | Possible Cause | Step-by-Step DIY Fix | Suggested Actions |
|---|---|---|---|---|
Even with Ultraheat switched on, the control panel's green LED stays dark | No 230 V~ power supply available to the unit. | — | Check 230 V~ power supply: verify if other 230 V~ appliances work in the vehicle, check if the line power cable is connected, check if the campsite fuse/circuit breaker has tripped, check if the vehicle residual current circuit-breaker (FI) or distribution board fuses have tripped. | DIY Safe |
Unusual noises or smells | Potential obstruction, dust accumulation, or overheating condition. | — | Turn off the gas supply, the heater and Ultraheat, and have a qualified expert check the system. | DIY Check / Tech Fallback |
Even with Ultraheat switched on, the control panel's green LED stays unlit. | No 230V power supply is available or reaching the device. | — | Check the 230V power supply: verify if other 230V appliances in the vehicle work, ensure the line power cable is connected, check if the campsite fuse box has tripped, and inspect the vehicle's internal 230V distribution board fuses and residual current circuit-breaker (RCCB). | DIY Safe |
N/A | Damage from improper cable routing or fan operation | Cables routed too close to hot parts, or the fan run without the proper warm-air ducts directing hot air onto the control unit. | Route cables away from hot parts and ensure the correct warm-air ducts are fitted before running the fan. | DIY Safe |
Frequently Asked Questions
Q: Can I use Ultraheat with older Truma S heaters like the Trumatic S 3002?
No - Ultraheat can't be used with any S-heater built before 04/2012, nor with the Trumatic S 3002, S 3002 P, S 5002, S 2200, S 55 T, or S 3002 K / S 5002 K.
Q: What fan setting should be used during electrical mode?
On electrical mode, run the fan at level 3 or above (manual or automatic) to spread warm air through the vehicle quickly and evenly.
Q: Can the Ultraheat be operated separately outside of a Truma S-heater?
No - Ultraheat (the electric additional heater) is only approved for fitting and running inside a compatible S-heater, never on its own or outside a vehicle.
Q: What power settings are available on the Ultraheat?
The additional heater features three operating power levels: 500 Watts, 1000 Watts, and 2000 Watts.
Q: Can the S-heater run on gas and the electric Ultraheat together?
Yes - the S-heater can run on gas while the electric additional heater runs too, though the additional heater may cut out on its own to guard against overheating.
Auto-SleepersLighting (Berkshire & Hampshire, 2009 Model Year)
Lighting2000 FAQs
Lighting (Berkshire & Hampshire, 2009 Model Year)
LightingMaster Troubleshooting & Diagnostics Matrix
| Error Code / Indicator | Symptom / Meaning | Possible Cause | Step-by-Step DIY Fix | Suggested Actions |
|---|---|---|---|---|
N/A | Lights dull/only one tube illuminating | Low battery charge | Check battery | DIY Safe |
N/A | Lights dull/only one tube illuminating | Faulty light unit/tube | Replace/Check | DIY Safe |
Auto-SleepersRefrigeration & Cooling (Berkshire & Hampshire, 2009 Model Year)
Fridge / Freezer4061 FAQ
Refrigeration & Cooling (Berkshire & Hampshire, 2009 Model Year)
Fridge / FreezerMaster Troubleshooting & Diagnostics Matrix
| Error Code / Indicator | Symptom / Meaning | Possible Cause | Step-by-Step DIY Fix | Suggested Actions |
|---|---|---|---|---|
N/A | Refrigerator does not operate on 230V | Switch on refrigerator thermostat dial not 'on' | Check position of thermostat dial | DIY Safe |
N/A | Refrigerator does not operate on 230V | Element fault | Refer to dealer | Professional Intervention Required |
N/A | Fridge gas ignition not operating | Fuse 11 blown | Track down the fault and fit a replacement fuse of the identical rating. | DIY Safe |
Recommended partsAffiliate linksView 2 optionsHideCheck whether the blown fuse is a standard or a mini blade fuse (mini ones are roughly half the size), then choose the matching kit: This fault doesn't say which fuse rating has blown, only to replace it like-for-like. Both kits cover the common ratings (5A-30A) - match the rating printed on the blown fuse. Standard blade fusesCar Fuse Kit - 60pc Assorted Blade Fuses (5A-30A) with Storage Case and Fuse Puller~£5.994.5★ (1,500+ ratings), sold by KANGRUI, dispatched by Amazon - includes 15A blade fuses plus a puller and storage case View on Amazon →Mini blade fusesNilight 120pc Mini Blade Fuse Assortment (5A-30A, ATM/APM) with Fuse Puller~£5.244.5★ (2,500+ ratings), sold by Amazon - includes 15A mini blade fuses View on Amazon → | ||||
N/A | Fridge gas ignition not operating | Ignition control switch fault | Refer to dealer | Professional Intervention Required |
N/A | Fridge ignition switch flashes but gas does not ignite | Fault on fridge unit | Refer to dealer | Professional Intervention Required |
N/A | You can hear the ignition sparking, but the fridge switch itself doesn't flash. | Faulty fridge ignition switch | Refer to dealer | Professional Intervention Required |
N/A | Fridge does not operate on 12V when engine is running | Fuse 3 blown | Track down the fault and fit a replacement fuse of the identical rating. | DIY Safe |
Recommended partsAffiliate linksView 2 optionsHideCheck whether the blown fuse is a standard or a mini blade fuse (mini ones are roughly half the size), then choose the matching kit: This fault doesn't say which fuse rating has blown, only to replace it like-for-like. Both kits cover the common ratings (5A-30A) - match the rating printed on the blown fuse. Standard blade fusesCar Fuse Kit - 60pc Assorted Blade Fuses (5A-30A) with Storage Case and Fuse Puller~£5.994.5★ (1,500+ ratings), sold by KANGRUI, dispatched by Amazon - includes 15A blade fuses plus a puller and storage case View on Amazon →Mini blade fusesNilight 120pc Mini Blade Fuse Assortment (5A-30A, ATM/APM) with Fuse Puller~£5.244.5★ (2,500+ ratings), sold by Amazon - includes 15A mini blade fuses View on Amazon → | ||||
N/A | Fridge does not operate on 12V when engine is running | Fuse 7 in EM50 interface box blown | Track down the fault and fit a replacement fuse of the identical rating. | DIY Safe |
Recommended partsAffiliate linksView 2 optionsHideCheck whether the blown fuse is a standard or a mini blade fuse (mini ones are roughly half the size), then choose the matching kit: This fault doesn't say which fuse rating has blown, only to replace it like-for-like. Both kits cover the common ratings (5A-30A) - match the rating printed on the blown fuse. Standard blade fusesCar Fuse Kit - 60pc Assorted Blade Fuses (5A-30A) with Storage Case and Fuse Puller~£5.994.5★ (1,500+ ratings), sold by KANGRUI, dispatched by Amazon - includes 15A blade fuses plus a puller and storage case View on Amazon →Mini blade fusesNilight 120pc Mini Blade Fuse Assortment (5A-30A, ATM/APM) with Fuse Puller~£5.244.5★ (2,500+ ratings), sold by Amazon - includes 15A mini blade fuses View on Amazon → | ||||
N/A | Fridge does not operate on 12V when engine is running | Fault on fridge relay | Refer to dealer | Professional Intervention Required |
N/A | Fridge does not operate on 12V when engine is running | Fault on fridge unit | Refer to dealer | Professional Intervention Required |
Frequently Asked Questions
Q: Does the refrigerator need a winter cover?
Below +8°C outside, fit the optional winter covers to shield the unit from the worst of the cold air, making sure they're properly fastened on. They also need to be on whenever you're driving, since EU Type Approval classes them as an external projection - so it's no extra effort to leave them fitted while the vehicle's laid up for winter too.
DometicRM7000 Series
Fridge / Freezer4008 FAQs
RM7000 Series
Fridge / FreezerTechnical Specifications
Master Troubleshooting & Diagnostics Matrix
| Error Code / Indicator | Symptom / Meaning | Possible Cause | Step-by-Step DIY Fix | Suggested Actions |
|---|---|---|---|---|
N/A | Refrigerator does not function on gas mode | Gas bottle empty or gas tap closed | Replace gas bottle and open all gas supply isolation valves | DIY Safe |
N/A | Refrigerator does not function on 12V DC | Blown 12V fuse or battery not charged | Replace fuse or recharge/check vehicle battery and engine connection | DIY Safe |
N/A | Refrigerator does not function on 230V AC | Blown 230V fuse or external power disconnected | Replace fuse or verify external mains power supply connection; on AES-equipped units, insufficient supply voltage can make the fridge switch itself over to gas operation automatically, reverting to 230V once voltage is adequate again. | DIY Safe |
N/A | Refrigerator does not cool sufficiently | Inadequate ventilation of the unit or incorrect thermostat setting | Check the ventilation grilles aren't covered, set the thermostat higher, check the door seals properly when shut if the condenser has iced up, let warm food cool before it goes in, and if the fridge has only just been switched on, give it several hours before checking again. | DIY Safe |
Frequently Asked Questions
Q: What does the SN climate class on my Dometic RM fridge mean?
Climate class SN (which Dometic calls 'Extended Temperate') means the fridge is designed to work reliably when the air temperature is from +10°C up to +32°C (taken at the bottom vent grille, outside the vehicle).
Q: How well does an absorption fridge cool in hot weather?
In a hot summer the outside temperature often reaches about 32°C - the top of the fridge's rated range - and once it climbs higher, the temperature inside the fridge will inevitably rise. An absorption fridge needs a heat source to move its refrigerant around the cooling unit (which is why it can run on 12V, 230V or gas), so it has to get rid of the heat from its power source as well as the heat drawn out of the food compartment.
To help it in hot weather: park where the fridge vents get as much shade as possible during the day; unclip the outside vent grilles to improve airflow; and if you regularly travel somewhere hot, consider having a ventilator kit (a fan fitted behind the fridge) installed to boost the airflow - Dometic lists these among its accessories.
Q: What can replace my old Dometic RM fridge?
Dometic's 2023 'New for old - simply swap' guide covers both its absorption and compressor fridges, showing which current models replace older ones. It's available from the catalogues section of Dometic's website.
Q: My fridge won't work on mains (AC) power - what should I check?
Check the fuse in the mains supply and replace it if it has blown, and make sure the vehicle is actually plugged into a mains supply. If both are fine, the AC heating element may have failed - that needs an authorised Dometic service centre.
Q: My fridge won't work on 12V (DC) - what should I check?
Possible causes, and what to do: the vehicle's own fuse has blown - replace it (see the vehicle's handbook); the vehicle battery is flat - test it and recharge it; the ignition is off - switch it on. If the fuse in the fridge's DC cable has blown (the fuse on the relay) or the DC heating element has failed, contact an authorised Dometic service centre.
Q: My fridge won't work on gas - what should I check?
Check the gas cylinder isn't empty (change it if it is) and that the gas valve is turned on. If air has got into the gas pipe, turn the fridge off and on again, repeating this three or four times if needed; if a gas hob or cooker is fitted, switch that on, then try the fridge again if needed.
Q: Why is my fridge running on gas in automatic mode when I'm plugged into mains?
The mains voltage is too low. The fridge switches back to mains by itself once the supply voltage recovers.
Q: Why isn't my fridge getting cold enough?
Work through the likely causes: the cooling unit isn't getting enough air - make sure the outside vent grilles aren't blocked; the evaporator has iced up - check the door shuts properly and the seal is seated and undamaged, then defrost the fridge; the temperature setting is too warm - turn it to a colder setting; it's very hot outside - take the vent grille off for a while so hot air can escape faster; too much food, or too much warm food, went in at once - take some out, and let warm food cool before putting it back; the fridge was only switched on recently - give it four to five hours, then recheck the temperature.
Auto-SleepersWater System (Berkshire & Hampshire, 2009 Model Year)
Water System Component13121 FAQ
Water System (Berkshire & Hampshire, 2009 Model Year)
Water System ComponentMaster Troubleshooting & Diagnostics Matrix
| Error Code / Indicator | Symptom / Meaning | Possible Cause | Step-by-Step DIY Fix | Suggested Actions |
|---|---|---|---|---|
N/A | Water pump not operating | Switch on panel 'off' | Switch it 'on' | DIY Safe |
N/A | Water pump not operating | Pressure switch on pump not operating | Refer to dealer | Professional Intervention Required |
N/A | Water pump not operating | Fuse 4 blown | Track down the fault and fit a replacement fuse of the identical rating. | DIY Safe |
Recommended partsAffiliate linksView 2 optionsHideCheck whether the blown fuse is a standard or a mini blade fuse (mini ones are roughly half the size), then choose the matching kit: This fault doesn't say which fuse rating has blown, only to replace it like-for-like. Both kits cover the common ratings (5A-30A) - match the rating printed on the blown fuse. Standard blade fusesCar Fuse Kit - 60pc Assorted Blade Fuses (5A-30A) with Storage Case and Fuse Puller~£5.994.5★ (1,500+ ratings), sold by KANGRUI, dispatched by Amazon - includes 15A blade fuses plus a puller and storage case View on Amazon →Mini blade fusesNilight 120pc Mini Blade Fuse Assortment (5A-30A, ATM/APM) with Fuse Puller~£5.244.5★ (2,500+ ratings), sold by Amazon - includes 15A mini blade fuses View on Amazon → | ||||
N/A | Water pump not operating | Pump feed setting at the control panel doesn't match what's wanted | The EC325 control panel is what governs the pump feed, both the one inside and the one outside - check its switch (tap button) is set the way you actually want. | DIY Safe |
N/A | Continuous running of water pump | No water | Fill tank | DIY Safe |
N/A | Continuous running of water pump | Major leak | Turn the system off straight away and check it over. | DIY Safe |
N/A | Intermittent operation of water pump | Minor leak in water system | Check push fit joints | DIY Safe |
N/A | Intermittent operation of water pump | Water pump pressure release valve reasserting itself | Nothing to do - this is simply how the pump is designed to behave. | DIY Safe |
N/A | Water pump does not operate | Fuse 4 blown | Track down the fault and fit a replacement fuse of the identical rating. | DIY Safe |
Recommended partsAffiliate linksView 2 optionsHideCheck whether the blown fuse is a standard or a mini blade fuse (mini ones are roughly half the size), then choose the matching kit: This fault doesn't say which fuse rating has blown, only to replace it like-for-like. Both kits cover the common ratings (5A-30A) - match the rating printed on the blown fuse. Standard blade fusesCar Fuse Kit - 60pc Assorted Blade Fuses (5A-30A) with Storage Case and Fuse Puller~£5.994.5★ (1,500+ ratings), sold by KANGRUI, dispatched by Amazon - includes 15A blade fuses plus a puller and storage case View on Amazon →Mini blade fusesNilight 120pc Mini Blade Fuse Assortment (5A-30A, ATM/APM) with Fuse Puller~£5.244.5★ (2,500+ ratings), sold by Amazon - includes 15A mini blade fuses View on Amazon → | ||||
N/A | Water gauge does not operate | Probe fault | Refer to dealer (check probe connections) | DIY Check / Tech Fallback |
N/A | Slow drainage from sink/shower tray | Blocked breathers in waste tank | Drop tank and clear breathers | DIY Safe |
N/A | Tip-up handbasin slow to drain | Blocked drain hole | Remove basin and clear | DIY Safe |
N/A | Unsatisfactory operation of water pump | Filter blocked | Clean filter | DIY Safe |
N/A | Pump feed does not operate (PSU control panel) | A fuse has blown | Replace with the correct-rated fuse. | DIY Safe |
Recommended partsAffiliate linksView 2 optionsHideCheck whether the blown fuse is a standard or a mini blade fuse (mini ones are roughly half the size), then choose the matching kit: This fault doesn't say which fuse rating has blown, only to replace it like-for-like. Both kits cover the common ratings (5A-30A) - match the rating printed on the blown fuse. Standard blade fusesCar Fuse Kit - 60pc Assorted Blade Fuses (5A-30A) with Storage Case and Fuse Puller~£5.994.5★ (1,500+ ratings), sold by KANGRUI, dispatched by Amazon - includes 15A blade fuses plus a puller and storage case View on Amazon →Mini blade fusesNilight 120pc Mini Blade Fuse Assortment (5A-30A, ATM/APM) with Fuse Puller~£5.244.5★ (2,500+ ratings), sold by Amazon - includes 15A mini blade fuses View on Amazon → | ||||
N/A | Pump feed does not operate (PSU control panel) | Pump switched off | Press the tap-symbol pump button on the control panel to switch it back on. | DIY Safe |
N/A | Pump feed does not operate (PSU control panel) | Pump setting incorrect | The control panel governs the pump's feed, both internal and external, as one setting - if it needs changing, that's a job for your dealer, so confirm it matches what you actually need. | Professional Intervention Required |
Frequently Asked Questions
Q: How do I winterise the water system before storing the vehicle for winter?
Empty the water system completely: leave both the fresh and waste tank drain taps open, along with every internal tap, and keep the pump running until nothing more comes through. If you're expecting particularly hard frost, it's also worth taking out the water filter on the pump's outlet side and clearing it of water while you're at it - a handy moment to give it a clean before next season too.
Pull the sink plugs so air can get into the system, flush the waste tank thoroughly to shift any debris, finish with a mild disinfectant flush, and leave the drain tap open.
TrumaUltrastore Water Heater
Water Heater5100 FAQs
Ultrastore Water Heater
Water HeaterTechnical Specifications
Master Troubleshooting & Diagnostics Matrix
| Error Code / Indicator | Symptom / Meaning | Possible Cause | Step-by-Step DIY Fix | Suggested Actions |
|---|---|---|---|---|
N/A | The heater switches on but doesn't run (gas operation) | No 12V supply, or a window above the cowl is open. | Check the power supply is at least 10.5V, check the water heater's fuse, and shut any window that's above the cowl. | DIY Safe |
N/A | The heater switches on but doesn't run, and the red lamp comes on (gas operation) | Cowl cover fitted, air in the gas supply, no gas supply, or incorrect gas pressure. | Take off the cowl cover and/or clear any blockage. Check the gas valves and gas bottle. Switch the appliance off for 5 minutes and back on to unlock it and purge any trapped air. | DIY Safe |
N/A | The heater runs for a while, then the red lamp comes on (gas operation) | Over-temperature thermostat has operated. | Top up the water content if needed (close the drain valve first). Switch the appliance off for 5 minutes and back on to unlock it. | DIY Safe |
N/A | The heater won't run once switched on (electrical operation) | No 230V supply voltage, or the over-temperature thermostat has operated. | Connect to the site's mains supply and/or check the residual current breaker. Top up the water content if needed (close the drain valve first). The electric heating element has its own excess-temperature cut-out - use the control panel to turn it off, wait 5 minutes, then turn it back on. | DIY Safe |
N/A | The safety/drain valve is dripping water | Water pressure too high. | Check the water pressure doesn't exceed 2.8 bar - fit a pressure reducer if it's on mains water. | DIY Safe |
N/A | Hot water comes out when the cold tap is opened | Hot water flows back through the cold water supply. | Fit a non-return valve on the cold supply as the installation instructions describe. If it keeps happening, contact Truma Service. | DIY Check / Tech Fallback |
Auto-SleepersBlinds & Flyscreens (Berkshire & Hampshire, 2009 Model Year)
Blind / Window Covering0100 FAQs
Blinds & Flyscreens (Berkshire & Hampshire, 2009 Model Year)
Blind / Window CoveringMaster Troubleshooting & Diagnostics Matrix
| Error Code / Indicator | Symptom / Meaning | Possible Cause | Step-by-Step DIY Fix | Suggested Actions |
|---|---|---|---|---|
N/A | Concertina blind or flyscreen has become stiff and difficult to operate | The mechanism has dried out or picked up dust/grit over time - these units need only light, occasional lubrication. | Apply a light lubricant to the mechanism. Avoid cleaning solvents or aerosols on the blind material itself, as it's a paper-type fabric that these can damage. If the problem persists, contact your Auto-Sleepers dealer. | DIY Check / Tech Fallback |