Avante models: 462, 540, 550, 564, 566, 574, 576, 636
Elddis Heating
(Avante, 2015 Model Year)
Also Fitted To This Caravan
Master Troubleshooting & Diagnostics Matrix
| Error Code / Indicator | Symptom / Meaning | Possible Cause | Step-by-Step DIY Fix | Suggested Actions |
|---|---|---|---|---|
N/A | iVan Control Panel: Space Heater diagnostic screen shows a gas supply fault | No gas in the bottle, a blockage in the gas line, or using Butane below +5°C | Check there's gas in the bottle and no blockage in the line, use Propane rather than Butane below +5°C, then press Retry. If the gas supply issue can't be resolved immediately, select an electric-only heating option instead. | DIY Safe |
N/A | iVan Control Panel: Space Heater diagnostic screen shows an overheat fault | The heater has overheated because a vent is closed or blocked (e.g. by a cushion or bag) | Clear whatever's blocking it and make sure no vents are shut, then give the heater 10 minutes to cool before trying it again. | DIY Safe |
N/A | iVan Control Panel: Space Heater diagnostic screen shows a voltage fault | Supply voltage is outside the 12V-15V operating range | Recharge the battery so the voltage is within range. | DIY Safe |
N/A | iVan Control Panel: Space Heater diagnostic screen shows a flue fault | Airflow through the Space Heater's flues is restricted | Inspect both flue ends and remove anything blocking them. | DIY Safe |
N/A | iVan Control Panel: Water Heater diagnostic screen shows a gas supply fault | No gas in the bottle, a blockage in the gas line, or using Butane below +5°C | Check there's gas in the bottle and no blockage in the line, use Propane rather than Butane below +5°C, then press Retry. If the gas supply issue can't be resolved immediately, select an electric-only heating option instead. | DIY Safe |
N/A | iVan Control Panel: Water Heater diagnostic screen shows a fault | The Water Heater hasn't been fully filled with water | Open a hot tap and run the pump until the water comes out smoothly, then give the heater at least 5 minutes to fill up fully before pressing Retry. | DIY Safe |
N/A | iVan Control Panel: Water Heater diagnostic screen shows a voltage fault | Supply voltage is outside the 12V-15V operating range | Recharge the battery so the voltage is within range. | DIY Safe |
N/A | iVan Control Panel shows a power consumption warning when a heater setting is selected | The combined heater load would exceed either the user-set current limit or the 16 Amp maximum | Select Cancel to return to the power setting screen and choose a lower setting, or select OK to accept the warning. | DIY Safe |