Elddis • Avante • Heating
Avante models: 462, 540, 550, 564, 566, 574, 576, 636

Elddis Heating

(Avante, 2015 Model Year)

Also Fitted To This Caravan

Master Troubleshooting & Diagnostics Matrix

Error Code / IndicatorSymptom / MeaningPossible CauseStep-by-Step DIY FixSuggested Actions
N/A
iVan Control Panel: Space Heater diagnostic screen shows a gas supply fault
No gas in the bottle, a blockage in the gas line, or using Butane below +5°C
Check there's gas in the bottle and no blockage in the line, use Propane rather than Butane below +5°C, then press Retry. If the gas supply issue can't be resolved immediately, select an electric-only heating option instead.
DIY Safe
N/A
iVan Control Panel: Space Heater diagnostic screen shows an overheat fault
The heater has overheated because a vent is closed or blocked (e.g. by a cushion or bag)
Clear whatever's blocking it and make sure no vents are shut, then give the heater 10 minutes to cool before trying it again.
DIY Safe
N/A
iVan Control Panel: Space Heater diagnostic screen shows a voltage fault
Supply voltage is outside the 12V-15V operating range
Recharge the battery so the voltage is within range.
DIY Safe
N/A
iVan Control Panel: Space Heater diagnostic screen shows a flue fault
Airflow through the Space Heater's flues is restricted
Inspect both flue ends and remove anything blocking them.
DIY Safe
N/A
iVan Control Panel: Water Heater diagnostic screen shows a gas supply fault
No gas in the bottle, a blockage in the gas line, or using Butane below +5°C
Check there's gas in the bottle and no blockage in the line, use Propane rather than Butane below +5°C, then press Retry. If the gas supply issue can't be resolved immediately, select an electric-only heating option instead.
DIY Safe
N/A
iVan Control Panel: Water Heater diagnostic screen shows a fault
The Water Heater hasn't been fully filled with water
Open a hot tap and run the pump until the water comes out smoothly, then give the heater at least 5 minutes to fill up fully before pressing Retry.
DIY Safe
N/A
iVan Control Panel: Water Heater diagnostic screen shows a voltage fault
Supply voltage is outside the 12V-15V operating range
Recharge the battery so the voltage is within range.
DIY Safe
N/A
iVan Control Panel shows a power consumption warning when a heater setting is selected
The combined heater load would exceed either the user-set current limit or the 16 Amp maximum
Select Cancel to return to the power setting screen and choose a lower setting, or select OK to accept the warning.
DIY Safe