Use the dropdowns below to set a start point, then browse the whole collection with the ‹ › arrows.
Auto-Sleepers • Kemerton • 2011
Complete guide — 101 diagnostic faults and 4 FAQs across 10 categories, assembled from every category document and cross-referenced part covering this exact edition.
Auto-SleepersCameras & Multimedia (Kemerton, 2011 Model Year)
Reversing Camera / Camera System0001 FAQ
Cameras & Multimedia (Kemerton, 2011 Model Year)
Reversing Camera / Camera SystemFrequently Asked Questions
Q: How does the reversing camera work?
Fitted next to the high-mounted rear stop lamp, this wide-angle colour camera feeds a monitor that clips over your existing interior mirror, switching on by itself the second you select reverse. Keep anything hard away from the LCD screen to avoid scratching it.
Auto-SleepersChassis & Running Gear (Kemerton, 2011 Model Year)
Chassis / Towing Control2001 FAQ
Chassis & Running Gear (Kemerton, 2011 Model Year)
Chassis / Towing ControlMaster Troubleshooting & Diagnostics Matrix
| Error Code / Indicator | Symptom / Meaning | Possible Cause | Step-by-Step DIY Fix | Suggested Actions |
|---|---|---|---|---|
N/A | The power-operated rear step is still out when the ignition gets switched on. | — | A buzzer behind the dashboard sounds the moment the ignition's switched on, and keeps going until the step's been fully retracted. | DIY Safe |
N/A | Dirt and frost preventing the electric step from operating properly | Accumulation of dirt or frost in moving parts | Clean or defrost the moving parts. | DIY Safe |
Frequently Asked Questions
Q: How does the electric rear step work?
This side step runs itself - leave it extended and a buzzer under the dashboard will sound as soon as the ignition's on, retracting the step automatically. Keep the moving parts clean and ice-free, since dirt or frost can stop it working properly.
Auto-SleepersCooking Equipment (Kemerton, 2011 Model Year)
Cooking2020 FAQs
Cooking Equipment (Kemerton, 2011 Model Year)
CookingMaster Troubleshooting & Diagnostics Matrix
| Error Code / Indicator | Symptom / Meaning | Possible Cause | Step-by-Step DIY Fix | Suggested Actions |
|---|---|---|---|---|
N/A | Cooker Hotplate not heating up | No power | Check MCB is on | DIY Safe |
N/A | Cooker ignition not operating | Fuse 11 blown | Track down the fault and fit a replacement fuse of the identical rating. | DIY Safe |
Recommended partsAffiliate linksView 2 optionsHideCheck whether the blown fuse is a standard or a mini blade fuse (mini ones are roughly half the size), then choose the matching kit: This fault doesn't say which fuse rating has blown, only to replace it like-for-like. Both kits cover the common ratings (5A-30A) - match the rating printed on the blown fuse. Standard blade fusesCar Fuse Kit - 60pc Assorted Blade Fuses (5A-30A) with Storage Case and Fuse Puller~£5.994.5★ (1,500+ ratings), sold by KANGRUI, dispatched by Amazon - includes 15A blade fuses plus a puller and storage case View on Amazon →Mini blade fusesNilight 120pc Mini Blade Fuse Assortment (5A-30A, ATM/APM) with Fuse Puller~£5.244.5★ (2,500+ ratings), sold by Amazon - includes 15A mini blade fuses View on Amazon → | ||||
N/A | Cooker ignition not operating | Spark unit fault | Refer to dealer | Professional Intervention Required |
N/A | Cooker ignition not operating | Fault on cooker unit | Refer to dealer | Professional Intervention Required |
Auto-SleepersElectrical System (Kemerton, 2011 Model Year)
Electrical31360 FAQs
Electrical System (Kemerton, 2011 Model Year)
ElectricalMaster Troubleshooting & Diagnostics Matrix
| Error Code / Indicator | Symptom / Meaning | Possible Cause | Step-by-Step DIY Fix | Suggested Actions |
|---|---|---|---|---|
N/A | Habitation 12V does not operate | Main 20A fuse blown | Check/Replace | DIY Safe |
N/A | Habitation 12V does not operate | Battery discharged | Recharge | DIY Safe |
N/A | Habitation 12V does not operate | The control panel's power switch is set to off. | Switch to on | DIY Safe |
N/A | Habitation 12V does not operate | Vehicle ignition 'on' | Switch 'off' ignition | DIY Safe |
N/A | Habitation battery not charging | Main 20A fuse blown | Check/Replace | DIY Safe |
N/A | Habitation battery not charging | Relay fault | Refer to dealer | Professional Intervention Required |
N/A | Habitation battery not charging | Contacts dirty/loose on battery terminals | Clean and check for tightness | DIY Safe |
N/A | Habitation battery not charging | Poor earthing | Check earthing to chassis point | DIY Safe |
N/A | Battery does not hold its charge | Failed battery | Check cells with hydrometer, change electrolyte if necessary | Professional Intervention Required |
N/A | Battery does not hold its charge | Current being drawn when not in use | Check all appliances are off | DIY Safe |
N/A | Battery discharges over a short time with appliances operating | Poor battery cell condition | Check cells with hydrometer | DIY Safe |
N/A | Battery discharges over a short time with appliances operating | Failed battery | Change battery | DIY Safe |
N/A | Battery discharges over a short time with appliances operating | Battery not fully charged | Fully recharge battery | DIY Safe |
N/A | One or more 12V appliances have no power reaching them. | Circuit fuse blown | Track down the fault and fit a replacement fuse of the identical rating. | DIY Safe |
Recommended partsAffiliate linksView 2 optionsHideCheck whether the blown fuse is a standard or a mini blade fuse (mini ones are roughly half the size), then choose the matching kit: This fault doesn't say which fuse rating has blown, only to replace it like-for-like. Both kits cover the common ratings (5A-30A) - match the rating printed on the blown fuse. Standard blade fusesCar Fuse Kit - 60pc Assorted Blade Fuses (5A-30A) with Storage Case and Fuse Puller~£5.994.5★ (1,500+ ratings), sold by KANGRUI, dispatched by Amazon - includes 15A blade fuses plus a puller and storage case View on Amazon →Mini blade fusesNilight 120pc Mini Blade Fuse Assortment (5A-30A, ATM/APM) with Fuse Puller~£5.244.5★ (2,500+ ratings), sold by Amazon - includes 15A mini blade fuses View on Amazon → | ||||
N/A | No power on 12V socket outlet | Fuse 9 blown | Track down the fault and fit a replacement fuse of the identical rating. | DIY Safe |
Recommended partsAffiliate linksView 2 optionsHideCheck whether the blown fuse is a standard or a mini blade fuse (mini ones are roughly half the size), then choose the matching kit: This fault doesn't say which fuse rating has blown, only to replace it like-for-like. Both kits cover the common ratings (5A-30A) - match the rating printed on the blown fuse. Standard blade fusesCar Fuse Kit - 60pc Assorted Blade Fuses (5A-30A) with Storage Case and Fuse Puller~£5.994.5★ (1,500+ ratings), sold by KANGRUI, dispatched by Amazon - includes 15A blade fuses plus a puller and storage case View on Amazon →Mini blade fusesNilight 120pc Mini Blade Fuse Assortment (5A-30A, ATM/APM) with Fuse Puller~£5.244.5★ (2,500+ ratings), sold by Amazon - includes 15A mini blade fuses View on Amazon → | ||||
N/A | No power on 12V socket outlet | 12V plug incorrectly connected/wired | Check plug | DIY Safe |
N/A | 230V system inoperative | No site power | Check site supply | DIY Safe |
N/A | 230V system inoperative | RCD/MCB switches tripped out | Reset circuit breakers | DIY Safe |
N/A | RCD/MCB keeps tripping out | Fault on 230V supply | Check supply including polarity | DIY Safe |
N/A | RCD/MCB keeps tripping out | Faulty appliance | Switch every appliance off, reset the circuit breakers, then switch appliances back on one at a time until the fault reappears - that identifies and isolates the faulty one. | DIY Safe |
N/A | RCD/MCB keeps tripping out | Overload on current consumption by appliance | 10A maximum available; do not use appliance | Professional Intervention Required |
N/A | Battery charger does not operate | Charger switched off | Switch on at control box/check MCB is on | DIY Safe |
N/A | No 230V output from the EC155 PSU | The lead linking the site supply to the vehicle isn't plugged in | Check the lead is connected properly - also check the socket where it plugs into the underside of the PSU. | DIY Safe |
N/A | No 230V output from the EC155 PSU | RCD switched off | Reset the RCD. | DIY Safe |
N/A | No 230V output from the EC155 PSU | RCD not operating correctly | Check the supply polarity; if the RCD keeps failing, contact your dealer, as there's likely an equipment or wiring fault. | DIY Check / Tech Fallback |
N/A | No 230V output from the EC155 PSU | MCB switched off | Reset the MCB by switching it off (down) then back on (up); if it keeps tripping, contact your dealer, as there's likely an equipment or wiring fault. | DIY Check / Tech Fallback |
N/A | No 230V output from the EC155 PSU | No or deficient supply from the site | Contact the site warden for assistance. | Professional Intervention Required |
N/A | No 230V output from the EC155 PSU | Some other fault | Contact your dealer. | Professional Intervention Required |
N/A | Control Panel has no display | — | Check the batteries, switch the charger on at the PSU, and confirm the mains supply is connected. Check the connecting lead at both the PSU and the control panel. If that doesn't resolve it, contact your dealer. | DIY Check / Tech Fallback |
N/A | 12V power switches itself off | — | This is usually the battery-save feature stepping in to protect the vehicle and/or leisure battery, or the engine having been started (in which case equipment gets disconnected automatically to meet EMC requirements). | DIY Safe |
N/A | Control panel display is corrupt or behaves erratically | — | The control panel's own software may have crashed. Reboot it either by switching off the PSU charger and pulling fuses 9 and 10 (the two 20A fuses covering the leisure and vehicle batteries), waiting 30 seconds, then refitting them and switching the charger back on - or by removing the control panel's bezel (pull down at the bottom centre), unplugging its multi-way connector, waiting 30 seconds, then reconnecting and reassembling. | DIY Safe |
N/A | No 12 volt output from the PSU | No 230V supply | Check the 230V supply first: the hook-up lead is plugged in at both ends, the RCD and MCB are both switched on (reset either one if it has tripped), and the site's own supply is actually live. | DIY Safe |
N/A | No 12 volt output from the PSU | Charger not switched on | Turn the charger switch on - it will illuminate when active. | DIY Safe |
N/A | No 12 volt output from the PSU | Battery not connected and/or not charged | Fit a charged battery. | DIY Safe |
Recommended partAffiliate linksView partHideOnly if your leisure battery needs replacing - check the size, type and terminal layout of the one fitted now, and that your charger supports it, before ordering: Leisure batteries vary by vehicle (size, capacity and type - lead-acid, AGM, EFB or lithium). This is a widely used 100Ah EFB battery, not a documented exact match for your vehicle. Leisure battery (100Ah EFB)Yuasa L36-EFB 12V 100Ah Leisure Battery~£1384.3★ (119 ratings), sold by Amazon - established battery brand View on Amazon → | ||||
N/A | No 12 volt output from the PSU | Power switch on the control panel not switched on | Turn the power on at the control panel. | DIY Safe |
N/A | No 12 volt output from the PSU | Battery flat, or its fuse blown | Recharge the battery, check the fuses, and confirm charging voltage is actually present at the battery. | DIY Safe |
N/A | No 12 volt output from the PSU | A fuse has blown | Make sure none of the fuses have blown and each one matches the rating shown on the fuse table. | DIY Safe |
N/A | No 12 volt output from the PSU | Equipment switched off or unplugged | Check the equipment itself is switched on and properly connected to the 12V supply. | DIY Safe |
N/A | No 12 volt output from the PSU | PSU has overheated and shut down automatically | Reduce the load on the system and let the PSU cool down - it will restart on its own once it has. | DIY Safe |
N/A | No 12 volt output from the PSU | Some other fault | Contact your dealer. | Professional Intervention Required |
Auto-SleepersGas Supply System (Kemerton, 2011 Model Year)
Gas Regulator / Supply5040 FAQs
Gas Supply System (Kemerton, 2011 Model Year)
Gas Regulator / SupplyMaster Troubleshooting & Diagnostics Matrix
| Error Code / Indicator | Symptom / Meaning | Possible Cause | Step-by-Step DIY Fix | Suggested Actions |
|---|---|---|---|---|
N/A | Appliance will not light | No gas | Swap in a fresh cylinder, confirm it's turned on, and check the isolation valve is open. | DIY Safe |
N/A | Appliance will not light | Low battery (auto ignition) | Charge battery | DIY Safe |
N/A | Appliance lights but goes out immediately the FSD override is released | Flame supervision device (FSD) is not functioning correctly | Refer to dealer | Professional Intervention Required |
N/A | Odour | Gas leak | Shut down the gas supply at the cylinder without delay, and leave the system alone until it's been properly fixed. Should a cylinder appear to be leaking, relocate it - if it's safe to do so - well clear of anything that could ignite it, then get in touch with the site warden and/or your local gas supplier. | Professional Intervention Required |
N/A | Yellow flame | There isn't enough primary air reaching the burner - note that a little yellow tipping on the flame is normal and not a fault. | Refer to dealer | Professional Intervention Required |
N/A | Orange flame | Dust or dirt particles in the mixing tube are being carried through the burner ports. | Reduce the level of dust in the surrounding air. | DIY Safe |
N/A | Orange flame | Burner ports partially blocked | Refer to dealer | Professional Intervention Required |
N/A | Floating flame | Lack of secondary air | Make sure every vent is clear, including the vehicle's air inlet. | DIY Safe |
N/A | Floating flame | Blocked retention ports | Make sure the retention ports aren't blocked; on an oven, also confirm the flue way isn't obstructed. | DIY Safe |
Auto-SleepersHeating (Kemerton, 2011 Model Year)
Heating System (Space/Water)6020 FAQs
Heating (Kemerton, 2011 Model Year)
Heating System (Space/Water)Master Troubleshooting & Diagnostics Matrix
| Error Code / Indicator | Symptom / Meaning | Possible Cause | Step-by-Step DIY Fix | Suggested Actions |
|---|---|---|---|---|
N/A | Water heater does not operate on 230V | No power | Switch on isolator switch/check MCB is on | DIY Safe |
N/A | Water heater does not operate on 230V | Overtemperature trip activated | Reset the thermal cut-out, following the operating instructions. | DIY Safe |
N/A | Water Heater not operating/cuts out | Fuse 11 blown | Track down the fault and fit a replacement fuse of the identical rating. | DIY Safe |
Recommended partsAffiliate linksView 2 optionsHideCheck whether the blown fuse is a standard or a mini blade fuse (mini ones are roughly half the size), then choose the matching kit: This fault doesn't say which fuse rating has blown, only to replace it like-for-like. Both kits cover the common ratings (5A-30A) - match the rating printed on the blown fuse. Standard blade fusesCar Fuse Kit - 60pc Assorted Blade Fuses (5A-30A) with Storage Case and Fuse Puller~£5.994.5★ (1,500+ ratings), sold by KANGRUI, dispatched by Amazon - includes 15A blade fuses plus a puller and storage case View on Amazon →Mini blade fusesNilight 120pc Mini Blade Fuse Assortment (5A-30A, ATM/APM) with Fuse Puller~£5.244.5★ (2,500+ ratings), sold by Amazon - includes 15A mini blade fuses View on Amazon → | ||||
N/A | Water Heater not operating/cuts out | Low battery charge | Recharge battery | DIY Safe |
N/A | Water Heater not operating/cuts out | Unit fault | Refer to dealer | Professional Intervention Required |
N/A | No hot water (mains system) | Water heater tripped | Check and press re-set button | DIY Safe |
N/A | No hot water (gas system) | Gas module not lighting | Refer to dealer | Professional Intervention Required |
N/A | No hot water (gas system) | Igniter not working | Check 12V switched on | DIY Safe |
Auto-SleepersLighting (Kemerton, 2011 Model Year)
Lighting2000 FAQs
Lighting (Kemerton, 2011 Model Year)
LightingMaster Troubleshooting & Diagnostics Matrix
| Error Code / Indicator | Symptom / Meaning | Possible Cause | Step-by-Step DIY Fix | Suggested Actions |
|---|---|---|---|---|
N/A | Lights dull/only one tube illuminating | Low battery charge | Check battery | DIY Safe |
N/A | Lights dull/only one tube illuminating | Faulty light unit/tube | Replace/Check | DIY Safe |
Auto-SleepersRefrigeration & Cooling (Kemerton, 2011 Model Year)
Fridge / Freezer4061 FAQ
Refrigeration & Cooling (Kemerton, 2011 Model Year)
Fridge / FreezerMaster Troubleshooting & Diagnostics Matrix
| Error Code / Indicator | Symptom / Meaning | Possible Cause | Step-by-Step DIY Fix | Suggested Actions |
|---|---|---|---|---|
N/A | Refrigerator does not operate on 230V | Switch on refrigerator thermostat dial not 'on' | Check position of thermostat dial | DIY Safe |
N/A | Refrigerator does not operate on 230V | Element fault | Refer to dealer | Professional Intervention Required |
N/A | Fridge gas ignition not operating | Fuse 11 blown | Track down the fault and fit a replacement fuse of the identical rating. | DIY Safe |
Recommended partsAffiliate linksView 2 optionsHideCheck whether the blown fuse is a standard or a mini blade fuse (mini ones are roughly half the size), then choose the matching kit: This fault doesn't say which fuse rating has blown, only to replace it like-for-like. Both kits cover the common ratings (5A-30A) - match the rating printed on the blown fuse. Standard blade fusesCar Fuse Kit - 60pc Assorted Blade Fuses (5A-30A) with Storage Case and Fuse Puller~£5.994.5★ (1,500+ ratings), sold by KANGRUI, dispatched by Amazon - includes 15A blade fuses plus a puller and storage case View on Amazon →Mini blade fusesNilight 120pc Mini Blade Fuse Assortment (5A-30A, ATM/APM) with Fuse Puller~£5.244.5★ (2,500+ ratings), sold by Amazon - includes 15A mini blade fuses View on Amazon → | ||||
N/A | Fridge gas ignition not operating | Ignition control switch fault | Refer to dealer | Professional Intervention Required |
N/A | Fridge ignition switch flashes but gas does not ignite | Fault on fridge unit | Refer to dealer | Professional Intervention Required |
N/A | You can hear the ignition sparking, but the fridge switch itself doesn't flash. | Faulty fridge ignition switch | Refer to dealer | Professional Intervention Required |
N/A | Fridge does not operate on 12V when engine is running | Fuse 3 blown | Track down the fault and fit a replacement fuse of the identical rating. | DIY Safe |
Recommended partsAffiliate linksView 2 optionsHideCheck whether the blown fuse is a standard or a mini blade fuse (mini ones are roughly half the size), then choose the matching kit: This fault doesn't say which fuse rating has blown, only to replace it like-for-like. Both kits cover the common ratings (5A-30A) - match the rating printed on the blown fuse. Standard blade fusesCar Fuse Kit - 60pc Assorted Blade Fuses (5A-30A) with Storage Case and Fuse Puller~£5.994.5★ (1,500+ ratings), sold by KANGRUI, dispatched by Amazon - includes 15A blade fuses plus a puller and storage case View on Amazon →Mini blade fusesNilight 120pc Mini Blade Fuse Assortment (5A-30A, ATM/APM) with Fuse Puller~£5.244.5★ (2,500+ ratings), sold by Amazon - includes 15A mini blade fuses View on Amazon → | ||||
N/A | Fridge does not operate on 12V when engine is running | Fuse 7 in EM50 interface box blown | Track down the fault and fit a replacement fuse of the identical rating. | DIY Safe |
Recommended partsAffiliate linksView 2 optionsHideCheck whether the blown fuse is a standard or a mini blade fuse (mini ones are roughly half the size), then choose the matching kit: This fault doesn't say which fuse rating has blown, only to replace it like-for-like. Both kits cover the common ratings (5A-30A) - match the rating printed on the blown fuse. Standard blade fusesCar Fuse Kit - 60pc Assorted Blade Fuses (5A-30A) with Storage Case and Fuse Puller~£5.994.5★ (1,500+ ratings), sold by KANGRUI, dispatched by Amazon - includes 15A blade fuses plus a puller and storage case View on Amazon →Mini blade fusesNilight 120pc Mini Blade Fuse Assortment (5A-30A, ATM/APM) with Fuse Puller~£5.244.5★ (2,500+ ratings), sold by Amazon - includes 15A mini blade fuses View on Amazon → | ||||
N/A | Fridge does not operate on 12V when engine is running | Fault on fridge relay | Refer to dealer | Professional Intervention Required |
N/A | Fridge does not operate on 12V when engine is running | Fault on fridge unit | Refer to dealer | Professional Intervention Required |
Frequently Asked Questions
Q: Does the refrigerator need a winter cover?
Not using the fridge for a while? Clear out the food, turn it off, give it a wipe down and shut off its gas supply. Prop the door open on its storage catch to let air circulate inside, and pop the winter cover over the outside ventilation grill.
ThetfordN97 Refrigerator (as fitted to Auto-Sleepers Peugeot Coachbuilt motorhomes, 2009-2017)
Fridge / Freezer7220 FAQs
N97 Refrigerator (as fitted to Auto-Sleepers Peugeot Coachbuilt motorhomes, 2009-2017)
Fridge / FreezerTechnical Specifications
Master Troubleshooting & Diagnostics Matrix
| Error Code / Indicator | Symptom / Meaning | Possible Cause | Step-by-Step DIY Fix | Suggested Actions |
|---|---|---|---|---|
N/A | Refrigerator will not work on gas | The gas bottle is empty, or the gas bottle valve or an isolation valve is closed. | Replace the gas bottle if empty, and open the gas bottle valve and any closed isolation valves. | DIY Safe |
N/A | Refrigerator will not work on 12V DC | The 12V fuse (fuse 3) is defective, or the habitation battery is flat. | Fit a new fuse (fuse number 3). Test the habitation battery and charge it if needed. | DIY Safe |
N/A | Refrigerator does not refrigerate sufficiently | Insufficient ventilation through the grills, the thermostat set too low, ice build-up on the condenser, too much food loaded in at once, a dirty gas burner, or the door not closing properly. | Check the ventilation grills aren't covered, increase the thermostat setting, check the door shuts properly and defrost the fridge if there's excess ice, let hot food cool before loading it in, have the gas burner cleaned, and check the door closing mechanism. | DIY Safe |
1, 2, 3, 4, 6, 7, 12, 14 | Refrigerator LCD displays fault code 1, 2, 3, 4, 6, 7, 12 or 14 | An internal AC/DC heater, gas-terminal or control-board fault with no user-serviceable cause. | Contact your dealer or a Thetford Service Centre directly. | Professional Intervention Required |
5 | Refrigerator LCD displays fault code 5 (senses a flame when gas should be off) | Flame sensor fault. | Contact your dealer or a Thetford Service Centre directly. | Professional Intervention Required |
8 | Refrigerator LCD displays fault code 8 (AC mains supply 20% below nominal) | The controls are in manual AC mode but there isn't enough power available. | Check that 230V is plugged in - if it is, the voltage supply itself is too low. Contact the site owner. | DIY Safe |
9 | Refrigerator LCD displays fault code 9 (gas lock-out, flame fails to ignite within 30 seconds) | The controls are in manual gas mode but the flame has failed to ignite - often an empty gas cylinder or a closed isolation valve. | Check whether the gas cylinder is empty or an isolation valve is closed. Select another energy source, or reset the refrigerator 3 or 4 times in gas mode until the flame ignites. Contact your dealer or a Thetford Service Centre if the problem persists. | DIY Check / Tech Fallback |
10 | Refrigerator LCD displays fault code 10 (no 'engine running' signal in manual DC mode) | The controls are in manual DC mode but the engine is not running - the refrigerator can only cool on 12V while the engine runs. | Start the engine or select a different energy source. | DIY Safe |
11 | Refrigerator LCD displays fault code 11 (no energy source available in AUTO mode) | The controls are in AUTO mode but no energy source is currently available. | Start the engine, connect the 230V supply, or open the gas supply, then reset the refrigerator by switching it off and on again. | DIY Safe |
13 | Refrigerator LCD displays fault code 13 (control switches automatically to Backup mode) | The thermistor has failed, often because its connector is not correctly plugged in. | Check that the connector above the fin on the inside of the cabinet is correctly plugged in. If it is, contact your dealer or a Thetford Service Centre. | DIY Check / Tech Fallback |
18 | Refrigerator LCD displays fault code 18 on start-up | Normal start-up behaviour - all LCD segments lighting briefly is not a fault. | Wait a few seconds for the refrigerator to start up normally. No action needed. | DIY Safe |
Auto-SleepersWater System (Kemerton, 2011 Model Year)
Water System Component12111 FAQ
Water System (Kemerton, 2011 Model Year)
Water System ComponentMaster Troubleshooting & Diagnostics Matrix
| Error Code / Indicator | Symptom / Meaning | Possible Cause | Step-by-Step DIY Fix | Suggested Actions |
|---|---|---|---|---|
N/A | Water pump not operating | Switch on panel 'off' | Switch it 'on' | DIY Safe |
N/A | Water pump not operating | Pressure switch on pump not operating | Refer to dealer | Professional Intervention Required |
N/A | Water pump not operating | Fuse 4 blown | Track down the fault and fit a replacement fuse of the identical rating. | DIY Safe |
Recommended partsAffiliate linksView 2 optionsHideCheck whether the blown fuse is a standard or a mini blade fuse (mini ones are roughly half the size), then choose the matching kit: This fault doesn't say which fuse rating has blown, only to replace it like-for-like. Both kits cover the common ratings (5A-30A) - match the rating printed on the blown fuse. Standard blade fusesCar Fuse Kit - 60pc Assorted Blade Fuses (5A-30A) with Storage Case and Fuse Puller~£5.994.5★ (1,500+ ratings), sold by KANGRUI, dispatched by Amazon - includes 15A blade fuses plus a puller and storage case View on Amazon →Mini blade fusesNilight 120pc Mini Blade Fuse Assortment (5A-30A, ATM/APM) with Fuse Puller~£5.244.5★ (2,500+ ratings), sold by Amazon - includes 15A mini blade fuses View on Amazon → | ||||
N/A | Continuous running of water pump | No water | Fill tank | DIY Safe |
N/A | Continuous running of water pump | Major leak | Turn the system off straight away and check it over. | DIY Safe |
N/A | Intermittent operation of water pump | Minor leak in water system | Check push fit joints | DIY Safe |
N/A | Intermittent operation of water pump | Water pump pressure release valve reasserting itself | Nothing to do - this is simply how the pump is designed to behave. | DIY Safe |
N/A | Water pump does not operate | Fuse 4 blown | Track down the fault and fit a replacement fuse of the identical rating. | DIY Safe |
Recommended partsAffiliate linksView 2 optionsHideCheck whether the blown fuse is a standard or a mini blade fuse (mini ones are roughly half the size), then choose the matching kit: This fault doesn't say which fuse rating has blown, only to replace it like-for-like. Both kits cover the common ratings (5A-30A) - match the rating printed on the blown fuse. Standard blade fusesCar Fuse Kit - 60pc Assorted Blade Fuses (5A-30A) with Storage Case and Fuse Puller~£5.994.5★ (1,500+ ratings), sold by KANGRUI, dispatched by Amazon - includes 15A blade fuses plus a puller and storage case View on Amazon →Mini blade fusesNilight 120pc Mini Blade Fuse Assortment (5A-30A, ATM/APM) with Fuse Puller~£5.244.5★ (2,500+ ratings), sold by Amazon - includes 15A mini blade fuses View on Amazon → | ||||
N/A | Water gauge does not operate | Probe fault | Refer to dealer (check probe connections) | DIY Check / Tech Fallback |
N/A | Slow drainage from sink/shower tray | Blocked breathers in waste tank | Drop tank and clear breathers | DIY Safe |
N/A | Tip-up handbasin slow to drain | Blocked drain hole | Remove basin and clear | DIY Safe |
N/A | Unsatisfactory operation of water pump | Filter blocked | Clean filter | DIY Safe |
N/A | Pump feed does not operate (PSU control panel) | A fuse has blown | Replace with the correct-rated fuse. | DIY Safe |
Recommended partsAffiliate linksView 2 optionsHideCheck whether the blown fuse is a standard or a mini blade fuse (mini ones are roughly half the size), then choose the matching kit: This fault doesn't say which fuse rating has blown, only to replace it like-for-like. Both kits cover the common ratings (5A-30A) - match the rating printed on the blown fuse. Standard blade fusesCar Fuse Kit - 60pc Assorted Blade Fuses (5A-30A) with Storage Case and Fuse Puller~£5.994.5★ (1,500+ ratings), sold by KANGRUI, dispatched by Amazon - includes 15A blade fuses plus a puller and storage case View on Amazon →Mini blade fusesNilight 120pc Mini Blade Fuse Assortment (5A-30A, ATM/APM) with Fuse Puller~£5.244.5★ (2,500+ ratings), sold by Amazon - includes 15A mini blade fuses View on Amazon → | ||||
N/A | Pump feed does not operate (PSU control panel) | Pump switched off | Press the tap-symbol pump button on the control panel to switch it back on. | DIY Safe |
Frequently Asked Questions
Q: How do I winterise the water system before storing the vehicle for winter?
Open the drain valve beside the water heater, then leave both the fresh and waste tank drain taps open along with every internal tap, and run the pump until it stops delivering water. Ahead of particularly severe frost, it's also worth taking out the water filter on the pump's outlet side and draining it - a convenient time to give it a clean before the next season.
Pull the sink plugs so the system can breathe, flush the waste tank thoroughly to clear debris, finish with a mild disinfectant flush, and leave the drain tap open.
Auto-SleepersBlinds & Flyscreens (Kemerton, 2011 Model Year)
Blind / Window Covering0100 FAQs
Blinds & Flyscreens (Kemerton, 2011 Model Year)
Blind / Window CoveringMaster Troubleshooting & Diagnostics Matrix
| Error Code / Indicator | Symptom / Meaning | Possible Cause | Step-by-Step DIY Fix | Suggested Actions |
|---|---|---|---|---|
N/A | Concertina blind or flyscreen has become stiff and difficult to operate | The mechanism has dried out or picked up dust/grit over time - these units need only light, occasional lubrication. | Apply a light lubricant to the mechanism. Avoid cleaning solvents or aerosols on the blind material itself, as it's a paper-type fabric that these can damage. If the problem persists, contact your Auto-Sleepers dealer. | DIY Check / Tech Fallback |
