Auto-Sleepers • Kemerton • 2011

717234 FAQs10 Types
Official manual on Auto-Sleepers's site:View PDF ↗
Auto-Sleepers

Cameras & Multimedia (Kemerton, 2011 Model Year)

Reversing Camera / Camera System
0001 FAQ
View official manual on manufacturer's site ↗

Frequently Asked Questions

Q: How does the reversing camera work?

Fitted next to the high-mounted rear stop lamp, this wide-angle colour camera feeds a monitor that clips over your existing interior mirror, switching on by itself the second you select reverse. Keep anything hard away from the LCD screen to avoid scratching it.

Auto-Sleepers

Chassis & Running Gear (Kemerton, 2011 Model Year)

Chassis / Towing Control
2001 FAQ
View official manual on manufacturer's site ↗

Master Troubleshooting & Diagnostics Matrix

Error Code / IndicatorSymptom / MeaningPossible CauseStep-by-Step DIY FixSuggested Actions
N/A
The power-operated rear step is still out when the ignition gets switched on.
—A buzzer behind the dashboard sounds the moment the ignition's switched on, and keeps going until the step's been fully retracted.DIY Safe
N/A
Dirt and frost preventing the electric step from operating properly
Accumulation of dirt or frost in moving partsClean or defrost the moving parts.DIY Safe

Frequently Asked Questions

Q: How does the electric rear step work?

This side step runs itself - leave it extended and a buzzer under the dashboard will sound as soon as the ignition's on, retracting the step automatically. Keep the moving parts clean and ice-free, since dirt or frost can stop it working properly.

Auto-Sleepers

Cooking Equipment (Kemerton, 2011 Model Year)

Cooking
2020 FAQs
View official manual on manufacturer's site ↗

Master Troubleshooting & Diagnostics Matrix

Error Code / IndicatorSymptom / MeaningPossible CauseStep-by-Step DIY FixSuggested Actions
N/A
Cooker Hotplate not heating up
No powerCheck MCB is onDIY Safe
N/A
Cooker ignition not operating
Fuse 11 blownTrack down the fault and fit a replacement fuse of the identical rating.DIY Safe
Recommended partsAffiliate linksView 2 optionsHide

Check whether the blown fuse is a standard or a mini blade fuse (mini ones are roughly half the size), then choose the matching kit:

This fault doesn't say which fuse rating has blown, only to replace it like-for-like. Both kits cover the common ratings (5A-30A) - match the rating printed on the blown fuse.

Standard blade fusesCar Fuse Kit - 60pc Assorted Blade Fuses (5A-30A) with Storage Case and Fuse Puller~£5.994.5★ (1,500+ ratings), sold by KANGRUI, dispatched by Amazon - includes 15A blade fuses plus a puller and storage case
View on Amazon →
Mini blade fusesNilight 120pc Mini Blade Fuse Assortment (5A-30A, ATM/APM) with Fuse Puller~£5.244.5★ (2,500+ ratings), sold by Amazon - includes 15A mini blade fuses
View on Amazon →
N/A
Cooker ignition not operating
Spark unit faultRefer to dealerProfessional Intervention Required
N/A
Cooker ignition not operating
Fault on cooker unitRefer to dealerProfessional Intervention Required
Auto-Sleepers

Electrical System (Kemerton, 2011 Model Year)

Electrical
31360 FAQs
View official manual on manufacturer's site ↗

Master Troubleshooting & Diagnostics Matrix

Error Code / IndicatorSymptom / MeaningPossible CauseStep-by-Step DIY FixSuggested Actions
N/A
Habitation 12V does not operate
Main 20A fuse blownCheck/ReplaceDIY Safe
N/A
Habitation 12V does not operate
Battery dischargedRechargeDIY Safe
N/A
Habitation 12V does not operate
The control panel's power switch is set to off.Switch to onDIY Safe
N/A
Habitation 12V does not operate
Vehicle ignition 'on'Switch 'off' ignitionDIY Safe
N/A
Habitation battery not charging
Main 20A fuse blownCheck/ReplaceDIY Safe
N/A
Habitation battery not charging
Relay faultRefer to dealerProfessional Intervention Required
N/A
Habitation battery not charging
Contacts dirty/loose on battery terminalsClean and check for tightnessDIY Safe
N/A
Habitation battery not charging
Poor earthingCheck earthing to chassis pointDIY Safe
N/A
Battery does not hold its charge
Failed batteryCheck cells with hydrometer, change electrolyte if necessaryProfessional Intervention Required
N/A
Battery does not hold its charge
Current being drawn when not in useCheck all appliances are offDIY Safe
N/A
Battery discharges over a short time with appliances operating
Poor battery cell conditionCheck cells with hydrometerDIY Safe
N/A
Battery discharges over a short time with appliances operating
Failed batteryChange batteryDIY Safe
N/A
Battery discharges over a short time with appliances operating
Battery not fully chargedFully recharge batteryDIY Safe
N/A
One or more 12V appliances have no power reaching them.
Circuit fuse blownTrack down the fault and fit a replacement fuse of the identical rating.DIY Safe
Recommended partsAffiliate linksView 2 optionsHide

Check whether the blown fuse is a standard or a mini blade fuse (mini ones are roughly half the size), then choose the matching kit:

This fault doesn't say which fuse rating has blown, only to replace it like-for-like. Both kits cover the common ratings (5A-30A) - match the rating printed on the blown fuse.

Standard blade fusesCar Fuse Kit - 60pc Assorted Blade Fuses (5A-30A) with Storage Case and Fuse Puller~£5.994.5★ (1,500+ ratings), sold by KANGRUI, dispatched by Amazon - includes 15A blade fuses plus a puller and storage case
View on Amazon →
Mini blade fusesNilight 120pc Mini Blade Fuse Assortment (5A-30A, ATM/APM) with Fuse Puller~£5.244.5★ (2,500+ ratings), sold by Amazon - includes 15A mini blade fuses
View on Amazon →
N/A
No power on 12V socket outlet
Fuse 9 blownTrack down the fault and fit a replacement fuse of the identical rating.DIY Safe
Recommended partsAffiliate linksView 2 optionsHide

Check whether the blown fuse is a standard or a mini blade fuse (mini ones are roughly half the size), then choose the matching kit:

This fault doesn't say which fuse rating has blown, only to replace it like-for-like. Both kits cover the common ratings (5A-30A) - match the rating printed on the blown fuse.

Standard blade fusesCar Fuse Kit - 60pc Assorted Blade Fuses (5A-30A) with Storage Case and Fuse Puller~£5.994.5★ (1,500+ ratings), sold by KANGRUI, dispatched by Amazon - includes 15A blade fuses plus a puller and storage case
View on Amazon →
Mini blade fusesNilight 120pc Mini Blade Fuse Assortment (5A-30A, ATM/APM) with Fuse Puller~£5.244.5★ (2,500+ ratings), sold by Amazon - includes 15A mini blade fuses
View on Amazon →
N/A
No power on 12V socket outlet
12V plug incorrectly connected/wiredCheck plugDIY Safe
N/A
230V system inoperative
No site powerCheck site supplyDIY Safe
N/A
230V system inoperative
RCD/MCB switches tripped outReset circuit breakersDIY Safe
N/A
RCD/MCB keeps tripping out
Fault on 230V supplyCheck supply including polarityDIY Safe
N/A
RCD/MCB keeps tripping out
Faulty applianceSwitch every appliance off, reset the circuit breakers, then switch appliances back on one at a time until the fault reappears - that identifies and isolates the faulty one.DIY Safe
N/A
RCD/MCB keeps tripping out
Overload on current consumption by appliance10A maximum available; do not use applianceProfessional Intervention Required
N/A
Battery charger does not operate
Charger switched offSwitch on at control box/check MCB is onDIY Safe
N/A
No 230V output from the EC155 PSU
The lead linking the site supply to the vehicle isn't plugged inCheck the lead is connected properly - also check the socket where it plugs into the underside of the PSU.DIY Safe
N/A
No 230V output from the EC155 PSU
RCD switched offReset the RCD.DIY Safe
N/A
No 230V output from the EC155 PSU
RCD not operating correctlyCheck the supply polarity; if the RCD keeps failing, contact your dealer, as there's likely an equipment or wiring fault.DIY Check / Tech Fallback
N/A
No 230V output from the EC155 PSU
MCB switched offReset the MCB by switching it off (down) then back on (up); if it keeps tripping, contact your dealer, as there's likely an equipment or wiring fault.DIY Check / Tech Fallback
N/A
No 230V output from the EC155 PSU
No or deficient supply from the siteContact the site warden for assistance.Professional Intervention Required
N/A
No 230V output from the EC155 PSU
Some other faultContact your dealer.Professional Intervention Required
N/A
Control Panel has no display
—Check the batteries, switch the charger on at the PSU, and confirm the mains supply is connected. Check the connecting lead at both the PSU and the control panel. If that doesn't resolve it, contact your dealer.DIY Check / Tech Fallback
N/A
12V power switches itself off
—This is usually the battery-save feature stepping in to protect the vehicle and/or leisure battery, or the engine having been started (in which case equipment gets disconnected automatically to meet EMC requirements).DIY Safe
N/A
Control panel display is corrupt or behaves erratically
—The control panel's own software may have crashed. Reboot it either by switching off the PSU charger and pulling fuses 9 and 10 (the two 20A fuses covering the leisure and vehicle batteries), waiting 30 seconds, then refitting them and switching the charger back on - or by removing the control panel's bezel (pull down at the bottom centre), unplugging its multi-way connector, waiting 30 seconds, then reconnecting and reassembling.DIY Safe
N/A
No 12 volt output from the PSU
No 230V supplyCheck the 230V supply first: the hook-up lead is plugged in at both ends, the RCD and MCB are both switched on (reset either one if it has tripped), and the site's own supply is actually live.DIY Safe
N/A
No 12 volt output from the PSU
Charger not switched onTurn the charger switch on - it will illuminate when active.DIY Safe
N/A
No 12 volt output from the PSU
Battery not connected and/or not chargedFit a charged battery.DIY Safe
Recommended partAffiliate linksView partHide

Only if your leisure battery needs replacing - check the size, type and terminal layout of the one fitted now, and that your charger supports it, before ordering:

Leisure batteries vary by vehicle (size, capacity and type - lead-acid, AGM, EFB or lithium). This is a widely used 100Ah EFB battery, not a documented exact match for your vehicle.

Leisure battery (100Ah EFB)Yuasa L36-EFB 12V 100Ah Leisure Battery~£1384.3★ (119 ratings), sold by Amazon - established battery brand
View on Amazon →
N/A
No 12 volt output from the PSU
Power switch on the control panel not switched onTurn the power on at the control panel.DIY Safe
N/A
No 12 volt output from the PSU
Battery flat, or its fuse blownRecharge the battery, check the fuses, and confirm charging voltage is actually present at the battery.DIY Safe
N/A
No 12 volt output from the PSU
A fuse has blownMake sure none of the fuses have blown and each one matches the rating shown on the fuse table.DIY Safe
N/A
No 12 volt output from the PSU
Equipment switched off or unpluggedCheck the equipment itself is switched on and properly connected to the 12V supply.DIY Safe
N/A
No 12 volt output from the PSU
PSU has overheated and shut down automaticallyReduce the load on the system and let the PSU cool down - it will restart on its own once it has.DIY Safe
N/A
No 12 volt output from the PSU
Some other faultContact your dealer.Professional Intervention Required
Auto-Sleepers

Gas Supply System (Kemerton, 2011 Model Year)

Gas Regulator / Supply
5040 FAQs
View official manual on manufacturer's site ↗

Master Troubleshooting & Diagnostics Matrix

Error Code / IndicatorSymptom / MeaningPossible CauseStep-by-Step DIY FixSuggested Actions
N/A
Appliance will not light
No gasSwap in a fresh cylinder, confirm it's turned on, and check the isolation valve is open.DIY Safe
N/A
Appliance will not light
Low battery (auto ignition)Charge batteryDIY Safe
N/A
Appliance lights but goes out immediately the FSD override is released
Flame supervision device (FSD) is not functioning correctlyRefer to dealerProfessional Intervention Required
N/A
Odour
Gas leakShut down the gas supply at the cylinder without delay, and leave the system alone until it's been properly fixed. Should a cylinder appear to be leaking, relocate it - if it's safe to do so - well clear of anything that could ignite it, then get in touch with the site warden and/or your local gas supplier.Professional Intervention Required
N/A
Yellow flame
There isn't enough primary air reaching the burner - note that a little yellow tipping on the flame is normal and not a fault.Refer to dealerProfessional Intervention Required
N/A
Orange flame
Dust or dirt particles in the mixing tube are being carried through the burner ports.Reduce the level of dust in the surrounding air.DIY Safe
N/A
Orange flame
Burner ports partially blockedRefer to dealerProfessional Intervention Required
N/A
Floating flame
Lack of secondary airMake sure every vent is clear, including the vehicle's air inlet.DIY Safe
N/A
Floating flame
Blocked retention portsMake sure the retention ports aren't blocked; on an oven, also confirm the flue way isn't obstructed.DIY Safe
Auto-Sleepers

Heating (Kemerton, 2011 Model Year)

Heating System (Space/Water)
6020 FAQs
View official manual on manufacturer's site ↗

Master Troubleshooting & Diagnostics Matrix

Error Code / IndicatorSymptom / MeaningPossible CauseStep-by-Step DIY FixSuggested Actions
N/A
Water heater does not operate on 230V
No powerSwitch on isolator switch/check MCB is onDIY Safe
N/A
Water heater does not operate on 230V
Overtemperature trip activatedReset the thermal cut-out, following the operating instructions.DIY Safe
N/A
Water Heater not operating/cuts out
Fuse 11 blownTrack down the fault and fit a replacement fuse of the identical rating.DIY Safe
Recommended partsAffiliate linksView 2 optionsHide

Check whether the blown fuse is a standard or a mini blade fuse (mini ones are roughly half the size), then choose the matching kit:

This fault doesn't say which fuse rating has blown, only to replace it like-for-like. Both kits cover the common ratings (5A-30A) - match the rating printed on the blown fuse.

Standard blade fusesCar Fuse Kit - 60pc Assorted Blade Fuses (5A-30A) with Storage Case and Fuse Puller~£5.994.5★ (1,500+ ratings), sold by KANGRUI, dispatched by Amazon - includes 15A blade fuses plus a puller and storage case
View on Amazon →
Mini blade fusesNilight 120pc Mini Blade Fuse Assortment (5A-30A, ATM/APM) with Fuse Puller~£5.244.5★ (2,500+ ratings), sold by Amazon - includes 15A mini blade fuses
View on Amazon →
N/A
Water Heater not operating/cuts out
Low battery chargeRecharge batteryDIY Safe
N/A
Water Heater not operating/cuts out
Unit faultRefer to dealerProfessional Intervention Required
N/A
No hot water (mains system)
Water heater trippedCheck and press re-set buttonDIY Safe
N/A
No hot water (gas system)
Gas module not lightingRefer to dealerProfessional Intervention Required
N/A
No hot water (gas system)
Igniter not workingCheck 12V switched onDIY Safe
Auto-Sleepers

Lighting (Kemerton, 2011 Model Year)

Lighting
2000 FAQs
View official manual on manufacturer's site ↗

Master Troubleshooting & Diagnostics Matrix

Error Code / IndicatorSymptom / MeaningPossible CauseStep-by-Step DIY FixSuggested Actions
N/A
Lights dull/only one tube illuminating
Low battery chargeCheck batteryDIY Safe
N/A
Lights dull/only one tube illuminating
Faulty light unit/tubeReplace/CheckDIY Safe
Note: more than one Fridge / Freezer is listed below for this exact vehicle edition. This isn't a mistake - manufacturers sometimes fit either option depending on the production run - but it means your vehicle almost certainly only has ONE of these, not both. Check your own appliance's badge/model plate against the entries below to find the right one.
Auto-Sleepers

Refrigeration & Cooling (Kemerton, 2011 Model Year)

Fridge / Freezer
4061 FAQ
View official manual on manufacturer's site ↗

Master Troubleshooting & Diagnostics Matrix

Error Code / IndicatorSymptom / MeaningPossible CauseStep-by-Step DIY FixSuggested Actions
N/A
Refrigerator does not operate on 230V
Switch on refrigerator thermostat dial not 'on'Check position of thermostat dialDIY Safe
N/A
Refrigerator does not operate on 230V
Element faultRefer to dealerProfessional Intervention Required
N/A
Fridge gas ignition not operating
Fuse 11 blownTrack down the fault and fit a replacement fuse of the identical rating.DIY Safe
Recommended partsAffiliate linksView 2 optionsHide

Check whether the blown fuse is a standard or a mini blade fuse (mini ones are roughly half the size), then choose the matching kit:

This fault doesn't say which fuse rating has blown, only to replace it like-for-like. Both kits cover the common ratings (5A-30A) - match the rating printed on the blown fuse.

Standard blade fusesCar Fuse Kit - 60pc Assorted Blade Fuses (5A-30A) with Storage Case and Fuse Puller~£5.994.5★ (1,500+ ratings), sold by KANGRUI, dispatched by Amazon - includes 15A blade fuses plus a puller and storage case
View on Amazon →
Mini blade fusesNilight 120pc Mini Blade Fuse Assortment (5A-30A, ATM/APM) with Fuse Puller~£5.244.5★ (2,500+ ratings), sold by Amazon - includes 15A mini blade fuses
View on Amazon →
N/A
Fridge gas ignition not operating
Ignition control switch faultRefer to dealerProfessional Intervention Required
N/A
Fridge ignition switch flashes but gas does not ignite
Fault on fridge unitRefer to dealerProfessional Intervention Required
N/A
You can hear the ignition sparking, but the fridge switch itself doesn't flash.
Faulty fridge ignition switchRefer to dealerProfessional Intervention Required
N/A
Fridge does not operate on 12V when engine is running
Fuse 3 blownTrack down the fault and fit a replacement fuse of the identical rating.DIY Safe
Recommended partsAffiliate linksView 2 optionsHide

Check whether the blown fuse is a standard or a mini blade fuse (mini ones are roughly half the size), then choose the matching kit:

This fault doesn't say which fuse rating has blown, only to replace it like-for-like. Both kits cover the common ratings (5A-30A) - match the rating printed on the blown fuse.

Standard blade fusesCar Fuse Kit - 60pc Assorted Blade Fuses (5A-30A) with Storage Case and Fuse Puller~£5.994.5★ (1,500+ ratings), sold by KANGRUI, dispatched by Amazon - includes 15A blade fuses plus a puller and storage case
View on Amazon →
Mini blade fusesNilight 120pc Mini Blade Fuse Assortment (5A-30A, ATM/APM) with Fuse Puller~£5.244.5★ (2,500+ ratings), sold by Amazon - includes 15A mini blade fuses
View on Amazon →
N/A
Fridge does not operate on 12V when engine is running
Fuse 7 in EM50 interface box blownTrack down the fault and fit a replacement fuse of the identical rating.DIY Safe
Recommended partsAffiliate linksView 2 optionsHide

Check whether the blown fuse is a standard or a mini blade fuse (mini ones are roughly half the size), then choose the matching kit:

This fault doesn't say which fuse rating has blown, only to replace it like-for-like. Both kits cover the common ratings (5A-30A) - match the rating printed on the blown fuse.

Standard blade fusesCar Fuse Kit - 60pc Assorted Blade Fuses (5A-30A) with Storage Case and Fuse Puller~£5.994.5★ (1,500+ ratings), sold by KANGRUI, dispatched by Amazon - includes 15A blade fuses plus a puller and storage case
View on Amazon →
Mini blade fusesNilight 120pc Mini Blade Fuse Assortment (5A-30A, ATM/APM) with Fuse Puller~£5.244.5★ (2,500+ ratings), sold by Amazon - includes 15A mini blade fuses
View on Amazon →
N/A
Fridge does not operate on 12V when engine is running
Fault on fridge relayRefer to dealerProfessional Intervention Required
N/A
Fridge does not operate on 12V when engine is running
Fault on fridge unitRefer to dealerProfessional Intervention Required

Frequently Asked Questions

Q: Does the refrigerator need a winter cover?

Not using the fridge for a while? Clear out the food, turn it off, give it a wipe down and shut off its gas supply. Prop the door open on its storage catch to let air circulate inside, and pop the winter cover over the outside ventilation grill.

Thetford

N97 Refrigerator (as fitted to Auto-Sleepers Peugeot Coachbuilt motorhomes, 2009-2017)

Fridge / Freezer
7220 FAQs
View full Thetford page →

Technical Specifications

Gross Volume88 litres (including freezer)
Freezer Capacity11 litres
Electricity Consumption2.8 kWh/24hr (average, 25°C ambient)
Gas Consumption0.33 kg/24hr (average, 25°C ambient)

Master Troubleshooting & Diagnostics Matrix

Error Code / IndicatorSymptom / MeaningPossible CauseStep-by-Step DIY FixSuggested Actions
N/A
Refrigerator will not work on gas
The gas bottle is empty, or the gas bottle valve or an isolation valve is closed.Replace the gas bottle if empty, and open the gas bottle valve and any closed isolation valves.DIY Safe
N/A
Refrigerator will not work on 12V DC
The 12V fuse (fuse 3) is defective, or the habitation battery is flat.Fit a new fuse (fuse number 3). Test the habitation battery and charge it if needed.DIY Safe
N/A
Refrigerator does not refrigerate sufficiently
Insufficient ventilation through the grills, the thermostat set too low, ice build-up on the condenser, too much food loaded in at once, a dirty gas burner, or the door not closing properly.Check the ventilation grills aren't covered, increase the thermostat setting, check the door shuts properly and defrost the fridge if there's excess ice, let hot food cool before loading it in, have the gas burner cleaned, and check the door closing mechanism.DIY Safe
1, 2, 3, 4, 6, 7, 12, 14
Refrigerator LCD displays fault code 1, 2, 3, 4, 6, 7, 12 or 14
An internal AC/DC heater, gas-terminal or control-board fault with no user-serviceable cause.Contact your dealer or a Thetford Service Centre directly.Professional Intervention Required
5
Refrigerator LCD displays fault code 5 (senses a flame when gas should be off)
Flame sensor fault.Contact your dealer or a Thetford Service Centre directly.Professional Intervention Required
8
Refrigerator LCD displays fault code 8 (AC mains supply 20% below nominal)
The controls are in manual AC mode but there isn't enough power available.Check that 230V is plugged in - if it is, the voltage supply itself is too low. Contact the site owner.DIY Safe
9
Refrigerator LCD displays fault code 9 (gas lock-out, flame fails to ignite within 30 seconds)
The controls are in manual gas mode but the flame has failed to ignite - often an empty gas cylinder or a closed isolation valve.Check whether the gas cylinder is empty or an isolation valve is closed. Select another energy source, or reset the refrigerator 3 or 4 times in gas mode until the flame ignites. Contact your dealer or a Thetford Service Centre if the problem persists.DIY Check / Tech Fallback
10
Refrigerator LCD displays fault code 10 (no 'engine running' signal in manual DC mode)
The controls are in manual DC mode but the engine is not running - the refrigerator can only cool on 12V while the engine runs.Start the engine or select a different energy source.DIY Safe
11
Refrigerator LCD displays fault code 11 (no energy source available in AUTO mode)
The controls are in AUTO mode but no energy source is currently available.Start the engine, connect the 230V supply, or open the gas supply, then reset the refrigerator by switching it off and on again.DIY Safe
13
Refrigerator LCD displays fault code 13 (control switches automatically to Backup mode)
The thermistor has failed, often because its connector is not correctly plugged in.Check that the connector above the fin on the inside of the cabinet is correctly plugged in. If it is, contact your dealer or a Thetford Service Centre.DIY Check / Tech Fallback
18
Refrigerator LCD displays fault code 18 on start-up
Normal start-up behaviour - all LCD segments lighting briefly is not a fault.Wait a few seconds for the refrigerator to start up normally. No action needed.DIY Safe
Auto-Sleepers

Water System (Kemerton, 2011 Model Year)

Water System Component
12111 FAQ
View official manual on manufacturer's site ↗

Master Troubleshooting & Diagnostics Matrix

Error Code / IndicatorSymptom / MeaningPossible CauseStep-by-Step DIY FixSuggested Actions
N/A
Water pump not operating
Switch on panel 'off'Switch it 'on'DIY Safe
N/A
Water pump not operating
Pressure switch on pump not operatingRefer to dealerProfessional Intervention Required
N/A
Water pump not operating
Fuse 4 blownTrack down the fault and fit a replacement fuse of the identical rating.DIY Safe
Recommended partsAffiliate linksView 2 optionsHide

Check whether the blown fuse is a standard or a mini blade fuse (mini ones are roughly half the size), then choose the matching kit:

This fault doesn't say which fuse rating has blown, only to replace it like-for-like. Both kits cover the common ratings (5A-30A) - match the rating printed on the blown fuse.

Standard blade fusesCar Fuse Kit - 60pc Assorted Blade Fuses (5A-30A) with Storage Case and Fuse Puller~£5.994.5★ (1,500+ ratings), sold by KANGRUI, dispatched by Amazon - includes 15A blade fuses plus a puller and storage case
View on Amazon →
Mini blade fusesNilight 120pc Mini Blade Fuse Assortment (5A-30A, ATM/APM) with Fuse Puller~£5.244.5★ (2,500+ ratings), sold by Amazon - includes 15A mini blade fuses
View on Amazon →
N/A
Continuous running of water pump
No waterFill tankDIY Safe
N/A
Continuous running of water pump
Major leakTurn the system off straight away and check it over.DIY Safe
N/A
Intermittent operation of water pump
Minor leak in water systemCheck push fit jointsDIY Safe
N/A
Intermittent operation of water pump
Water pump pressure release valve reasserting itselfNothing to do - this is simply how the pump is designed to behave.DIY Safe
N/A
Water pump does not operate
Fuse 4 blownTrack down the fault and fit a replacement fuse of the identical rating.DIY Safe
Recommended partsAffiliate linksView 2 optionsHide

Check whether the blown fuse is a standard or a mini blade fuse (mini ones are roughly half the size), then choose the matching kit:

This fault doesn't say which fuse rating has blown, only to replace it like-for-like. Both kits cover the common ratings (5A-30A) - match the rating printed on the blown fuse.

Standard blade fusesCar Fuse Kit - 60pc Assorted Blade Fuses (5A-30A) with Storage Case and Fuse Puller~£5.994.5★ (1,500+ ratings), sold by KANGRUI, dispatched by Amazon - includes 15A blade fuses plus a puller and storage case
View on Amazon →
Mini blade fusesNilight 120pc Mini Blade Fuse Assortment (5A-30A, ATM/APM) with Fuse Puller~£5.244.5★ (2,500+ ratings), sold by Amazon - includes 15A mini blade fuses
View on Amazon →
N/A
Water gauge does not operate
Probe faultRefer to dealer (check probe connections)DIY Check / Tech Fallback
N/A
Slow drainage from sink/shower tray
Blocked breathers in waste tankDrop tank and clear breathersDIY Safe
N/A
Tip-up handbasin slow to drain
Blocked drain holeRemove basin and clearDIY Safe
N/A
Unsatisfactory operation of water pump
Filter blockedClean filterDIY Safe
N/A
Pump feed does not operate (PSU control panel)
A fuse has blownReplace with the correct-rated fuse.DIY Safe
Recommended partsAffiliate linksView 2 optionsHide

Check whether the blown fuse is a standard or a mini blade fuse (mini ones are roughly half the size), then choose the matching kit:

This fault doesn't say which fuse rating has blown, only to replace it like-for-like. Both kits cover the common ratings (5A-30A) - match the rating printed on the blown fuse.

Standard blade fusesCar Fuse Kit - 60pc Assorted Blade Fuses (5A-30A) with Storage Case and Fuse Puller~£5.994.5★ (1,500+ ratings), sold by KANGRUI, dispatched by Amazon - includes 15A blade fuses plus a puller and storage case
View on Amazon →
Mini blade fusesNilight 120pc Mini Blade Fuse Assortment (5A-30A, ATM/APM) with Fuse Puller~£5.244.5★ (2,500+ ratings), sold by Amazon - includes 15A mini blade fuses
View on Amazon →
N/A
Pump feed does not operate (PSU control panel)
Pump switched offPress the tap-symbol pump button on the control panel to switch it back on.DIY Safe

Frequently Asked Questions

Q: How do I winterise the water system before storing the vehicle for winter?

Open the drain valve beside the water heater, then leave both the fresh and waste tank drain taps open along with every internal tap, and run the pump until it stops delivering water. Ahead of particularly severe frost, it's also worth taking out the water filter on the pump's outlet side and draining it - a convenient time to give it a clean before the next season.

Pull the sink plugs so the system can breathe, flush the waste tank thoroughly to clear debris, finish with a mild disinfectant flush, and leave the drain tap open.

Auto-Sleepers

Blinds & Flyscreens (Kemerton, 2011 Model Year)

Blind / Window Covering
0100 FAQs
View official manual on manufacturer's site ↗

Master Troubleshooting & Diagnostics Matrix

Error Code / IndicatorSymptom / MeaningPossible CauseStep-by-Step DIY FixSuggested Actions
N/A
Concertina blind or flyscreen has become stiff and difficult to operate
The mechanism has dried out or picked up dust/grit over time - these units need only light, occasional lubrication.Apply a light lubricant to the mechanism. Avoid cleaning solvents or aerosols on the blind material itself, as it's a paper-type fabric that these can damage. If the problem persists, contact your Auto-Sleepers dealer.DIY Check / Tech Fallback