Use the dropdowns below to set a start point, then browse the whole collection with the ‹ › arrows.
Auto-Sleepers • Broadway • 2012
Complete guide — 155 diagnostic faults and 10 FAQs across 10 categories, assembled from every category document and cross-referenced part covering this exact edition.
Auto-SleepersChassis & Running Gear (Broadway, 2012 Model Year)
Chassis / Towing Control2001 FAQ
Chassis & Running Gear (Broadway, 2012 Model Year)
Chassis / Towing ControlMaster Troubleshooting & Diagnostics Matrix
| Error Code / Indicator | Symptom / Meaning | Possible Cause | Step-by-Step DIY Fix | Suggested Actions |
|---|---|---|---|---|
N/A | The power-operated rear step is still out when the ignition gets switched on. | — | A buzzer behind the dashboard sounds the moment the ignition's switched on, and keeps going until the step's been fully retracted. | DIY Safe |
N/A | Dirt and frost preventing the electric step from operating properly | Accumulation of dirt or frost in moving parts | Clean or defrost the moving parts. | DIY Safe |
Frequently Asked Questions
Q: How does the electric rear step work?
A button by the entry door controls it - press once to send it out, press again to bring it back in. Starting the engine retracts it automatically, with a short buzzer as warning; if something's blocking it or it fails to retract, that buzzer carries on sounding until the fault's cleared. It's usually tied to the remote locking too - unlock the doors and it comes out, lock them and it goes back in - though your dealer can disable that link if you prefer.
Auto-SleepersCooking Equipment (Broadway, 2012 Model Year)
Cooking2020 FAQs
Cooking Equipment (Broadway, 2012 Model Year)
CookingMaster Troubleshooting & Diagnostics Matrix
| Error Code / Indicator | Symptom / Meaning | Possible Cause | Step-by-Step DIY Fix | Suggested Actions |
|---|---|---|---|---|
N/A | Cooker Hotplate not heating up | No power | Check MCB is on | DIY Safe |
N/A | Cooker ignition not operating | Fuse 11 blown | Track down the fault and fit a replacement fuse of the identical rating. | DIY Safe |
Recommended partsAffiliate linksView 2 optionsHideCheck whether the blown fuse is a standard or a mini blade fuse (mini ones are roughly half the size), then choose the matching kit: This fault doesn't say which fuse rating has blown, only to replace it like-for-like. Both kits cover the common ratings (5A-30A) - match the rating printed on the blown fuse. Standard blade fusesCar Fuse Kit - 60pc Assorted Blade Fuses (5A-30A) with Storage Case and Fuse Puller~£5.994.5★ (1,500+ ratings), sold by KANGRUI, dispatched by Amazon - includes 15A blade fuses plus a puller and storage case View on Amazon →Mini blade fusesNilight 120pc Mini Blade Fuse Assortment (5A-30A, ATM/APM) with Fuse Puller~£5.244.5★ (2,500+ ratings), sold by Amazon - includes 15A mini blade fuses View on Amazon → | ||||
N/A | Cooker ignition not operating | Spark unit fault | Refer to dealer | Professional Intervention Required |
N/A | Cooker ignition not operating | Fault on cooker unit | Refer to dealer | Professional Intervention Required |
DaewooKOR6L1B Microwave Oven (as fitted to Auto-Sleepers motorhomes)
Microwave1100 FAQs
KOR6L1B Microwave Oven (as fitted to Auto-Sleepers motorhomes)
MicrowaveTechnical Specifications
Master Troubleshooting & Diagnostics Matrix
| Error Code / Indicator | Symptom / Meaning | Possible Cause | Step-by-Step DIY Fix | Suggested Actions |
|---|---|---|---|---|
N/A | The microwave oven doesn't work | Not connected to mains, door not firmly closed, cooking time not set, or a blown fuse/tripped circuit breaker. | Make sure the power cord is plugged in securely, the door is shut firmly, and a cooking time has actually been set. Also check for a blown fuse or a tripped circuit breaker on the supply. | DIY Safe |
N/A | Sparking inside the microwave cavity | Metal cookware or metal-trimmed dishes are being used, or a metal skewer/foil is touching the inside walls of the oven. | Check you're not using any metal containers or metal-trimmed dishes, and that no metal skewer or foil is touching the oven's interior walls. Contact the service station if it keeps happening. | DIY Check / Tech Fallback |
Auto-SleepersElectrical System (Broadway, 2012 Model Year)
Electrical45880 FAQs
Electrical System (Broadway, 2012 Model Year)
ElectricalMaster Troubleshooting & Diagnostics Matrix
| Error Code / Indicator | Symptom / Meaning | Possible Cause | Step-by-Step DIY Fix | Suggested Actions |
|---|---|---|---|---|
N/A | Habitation 12V does not operate | Main 20A fuse blown | Check/Replace | DIY Safe |
N/A | Habitation 12V does not operate | Battery discharged | Recharge | DIY Safe |
N/A | Habitation 12V does not operate | The control panel's power switch is set to off. | Switch to on | DIY Safe |
N/A | Habitation 12V does not operate | Vehicle ignition 'on' | Switch 'off' ignition | DIY Safe |
N/A | Habitation battery not charging | Main 20A fuse blown | Check/Replace | DIY Safe |
N/A | Habitation battery not charging | Relay fault | Refer to dealer | Professional Intervention Required |
N/A | Habitation battery not charging | Contacts dirty/loose on battery terminals | Clean and check for tightness | DIY Safe |
N/A | Habitation battery not charging | Poor earthing | Check earthing to chassis point | DIY Safe |
N/A | Battery does not hold its charge | Failed battery | Check cells with hydrometer, change electrolyte if necessary | Professional Intervention Required |
N/A | Battery does not hold its charge | Current being drawn when not in use | Check all appliances are off | DIY Safe |
N/A | Battery discharges over a short time with appliances operating | Poor battery cell condition | Check cells with hydrometer | DIY Safe |
N/A | Battery discharges over a short time with appliances operating | Failed battery | Change battery | DIY Safe |
N/A | Battery discharges over a short time with appliances operating | Battery not fully charged | Fully recharge battery | DIY Safe |
N/A | One or more 12V appliances have no power reaching them. | Circuit fuse blown | Track down the fault and fit a replacement fuse of the identical rating. | DIY Safe |
Recommended partsAffiliate linksView 2 optionsHideCheck whether the blown fuse is a standard or a mini blade fuse (mini ones are roughly half the size), then choose the matching kit: This fault doesn't say which fuse rating has blown, only to replace it like-for-like. Both kits cover the common ratings (5A-30A) - match the rating printed on the blown fuse. Standard blade fusesCar Fuse Kit - 60pc Assorted Blade Fuses (5A-30A) with Storage Case and Fuse Puller~£5.994.5★ (1,500+ ratings), sold by KANGRUI, dispatched by Amazon - includes 15A blade fuses plus a puller and storage case View on Amazon →Mini blade fusesNilight 120pc Mini Blade Fuse Assortment (5A-30A, ATM/APM) with Fuse Puller~£5.244.5★ (2,500+ ratings), sold by Amazon - includes 15A mini blade fuses View on Amazon → | ||||
N/A | No power on 12V socket outlet | Fuse 9 blown | Track down the fault and fit a replacement fuse of the identical rating. | DIY Safe |
Recommended partsAffiliate linksView 2 optionsHideCheck whether the blown fuse is a standard or a mini blade fuse (mini ones are roughly half the size), then choose the matching kit: This fault doesn't say which fuse rating has blown, only to replace it like-for-like. Both kits cover the common ratings (5A-30A) - match the rating printed on the blown fuse. Standard blade fusesCar Fuse Kit - 60pc Assorted Blade Fuses (5A-30A) with Storage Case and Fuse Puller~£5.994.5★ (1,500+ ratings), sold by KANGRUI, dispatched by Amazon - includes 15A blade fuses plus a puller and storage case View on Amazon →Mini blade fusesNilight 120pc Mini Blade Fuse Assortment (5A-30A, ATM/APM) with Fuse Puller~£5.244.5★ (2,500+ ratings), sold by Amazon - includes 15A mini blade fuses View on Amazon → | ||||
N/A | No power on 12V socket outlet | 12V plug incorrectly connected/wired | Check plug | DIY Safe |
N/A | 230V system inoperative | No site power | Check site supply | DIY Safe |
N/A | 230V system inoperative | RCD/MCB switches tripped out | Reset circuit breakers | DIY Safe |
N/A | RCD/MCB keeps tripping out | Fault on 230V supply | Check supply including polarity | DIY Safe |
N/A | RCD/MCB keeps tripping out | Faulty appliance | Switch every appliance off, reset the circuit breakers, then switch appliances back on one at a time until the fault reappears - that identifies and isolates the faulty one. | DIY Safe |
N/A | RCD/MCB keeps tripping out | Overload on current consumption by appliance | 10A maximum available; do not use appliance | Professional Intervention Required |
N/A | Battery charger does not operate | Charger switched off | Switch on at control box/check MCB is on | DIY Safe |
N/A | No 230V output from the PSU | The lead linking the site supply to the vehicle isn't plugged in | Check the lead is connected correctly at both ends. | DIY Safe |
N/A | No 230V output from the PSU | RCD switched off | Reset the RCD. | DIY Safe |
N/A | No 230V output from the PSU | RCD not operating | Check the supply polarity; if the RCD keeps failing, contact your dealer, as there's likely an equipment or wiring fault. | DIY Check / Tech Fallback |
N/A | No 230V output from the PSU | MCB switched off | Reset the MCB by switching it off (down) then back on (up); if it keeps tripping, contact your dealer, as there's likely an equipment or wiring fault. | DIY Check / Tech Fallback |
N/A | No 230V output from the PSU | No or deficient supply from the site | Contact the site warden for assistance. | Professional Intervention Required |
N/A | Reverse polarity warning light is illuminated on the PSU | — | This light is designed to catch a reversed/crossed live and neutral supply on UK-wired sites - if it comes on, suspect a fault with the site's own supply, or its connecting cable (outside the UK it can light up with no actual fault present, so check with the site warden). It can also light up quite normally when running from certain generators, since some centre-tap their earth connection rather than earthing the neutral directly, leaving both conductors roughly 110V above earth - usually still safe to keep using in that case, but check the generator's own handbook. | DIY Check / Tech Fallback |
N/A | Control Panel has no display | — | The screen's backlight might have simply turned itself off - tap select to wake it again. If that's not it, work through the batteries and fuses, confirm both the shutdown switch and the charger switch on the PSU are set to on, and that mains is plugged in. Also check the lead running between the PSU and the back of the panel. Still nothing? Get in touch with your dealer. | DIY Check / Tech Fallback |
N/A | 12V power turns off unexpectedly | — | Usually the battery-protect feature has stepped in to protect the vehicle and/or leisure battery, or the engine's been started, in which case equipment is disconnected automatically to meet EMC requirements while driving. | DIY Safe |
N/A | Control panel is locked or behaves erratically | — | Check you're following the control panel's own handling instructions. If the panel's software has crashed, reboot it by turning off the PSU's isolator switch, waiting 30 seconds, then switching it back on. | DIY Safe |
N/A | No 12 volt output from the PSU | No 230V supply | Work through the 230V checks above first. | DIY Safe |
N/A | No 12 volt output from the PSU | Charger not switched on | Turn the charger switch on - it will illuminate when active. | DIY Safe |
N/A | No 12 volt output from the PSU | Battery not connected and/or not charged | Fit a charged battery. | DIY Safe |
Recommended partAffiliate linksView partHideOnly if your leisure battery needs replacing - check the size, type and terminal layout of the one fitted now, and that your charger supports it, before ordering: Leisure batteries vary by vehicle (size, capacity and type - lead-acid, AGM, EFB or lithium). This is a widely used 100Ah EFB battery, not a documented exact match for your vehicle. Leisure battery (100Ah EFB)Yuasa L36-EFB 12V 100Ah Leisure Battery~£1384.3★ (119 ratings), sold by Amazon - established battery brand View on Amazon → | ||||
N/A | No 12 volt output from the PSU | Power button on the control panel not switched on | Turn the power on at the control panel. | DIY Safe |
N/A | No 12 volt output from the PSU | Battery flat, or its fuse blown | Recharge the battery, check the fuses, and confirm charging voltage is actually present at the battery. | DIY Safe |
N/A | No 12 volt output from the PSU | A fuse has blown | Make sure none of the fuses have blown and each one matches the rating shown on the fuse table. | DIY Safe |
N/A | No 12 volt output from the PSU | Equipment switched off or unplugged | Check the equipment itself is switched on and properly connected to the 12V supply. | DIY Safe |
N/A | No 12 volt output from the PSU | PSU has overheated and shut down automatically | Reduce the load on the system and let the PSU cool down - it will restart on its own once it has. | DIY Safe |
N/A | No 12 volt output from the PSU | Some other fault | Contact your dealer. | Professional Intervention Required |
N/A | No 230V output from the EC325 PSU | The lead linking the site supply to the vehicle isn't plugged in | Check the lead is connected properly - also check the socket where it plugs into the underside of the PSU. | DIY Safe |
N/A | No 230V output from the EC325 PSU | RCD switched off | Reset the RCD. | DIY Safe |
N/A | No 230V output from the EC325 PSU | RCD not operating correctly | Check the supply polarity; if the RCD keeps failing, contact your dealer, as there's likely an equipment or wiring fault. | DIY Check / Tech Fallback |
N/A | No 230V output from the EC325 PSU | MCB switched off | Reset the MCB by switching it off (down) then back on (up); if it keeps tripping, contact your dealer, as there's likely an equipment or wiring fault. | DIY Check / Tech Fallback |
N/A | No 230V output from the EC325 PSU | No or deficient supply from the site | Contact the site warden for assistance. | Professional Intervention Required |
N/A | No 230V output from the EC325 PSU | Some other fault | Contact your dealer. | Professional Intervention Required |
N/A | Reverse polarity warning light is illuminated on the EC325 PSU | — | This light is designed to catch a reversed/crossed live and neutral supply on UK-wired sites - if it comes on, suspect a fault with the site's own supply, or its connecting cable (outside the UK it can light up with no actual fault present, so check with the site warden). It can also light up quite normally when running from certain generators, since some centre-tap their earth connection rather than earthing the neutral directly, leaving both conductors roughly 110V above earth - usually still safe to keep using in that case, but check the generator's own handbook. | DIY Check / Tech Fallback |
N/A | Control panel has no display | — | Check the batteries, switch the charger on at the PSU, and confirm the mains supply is connected. Check the connecting lead at both the PSU and the control panel. If that doesn't resolve it, contact your dealer. | DIY Check / Tech Fallback |
N/A | 12V power switches itself off | — | This is usually the battery-save feature stepping in to protect the vehicle and/or leisure battery, or the engine having been started (in which case equipment gets disconnected automatically to meet EMC requirements). | DIY Safe |
N/A | Control panel display is corrupt or behaves erratically | — | The control panel's own software may have crashed. Reboot it either by switching off the PSU charger and pulling fuses 1 and 2 (the two 20A fuses covering the leisure and vehicle batteries), waiting 30 seconds, then refitting them and switching the charger back on - or by removing the control panel's bezel (pull down at the bottom centre), unplugging its multi-way connector, waiting 30 seconds, then reconnecting and reassembling. | DIY Safe |
N/A | Control panel contrast is poor | — | Remove the control panel as for a reboot, but leave it plugged in, then carefully adjust the small contrast preset on the back using a jeweller's screwdriver. | DIY Safe |
N/A | Control panel's current reading is incorrect | — | Recalibrate the current sensor: with the charger switched off and the panel powered down (no LEDs lit), scroll the display to the battery current reading, then hold the select (left arrow) button until 'calibrating...' appears - keep holding until the reading reappears, then release. Repeat the whole process once more to store the new setting. | DIY Safe |
N/A | No 12 volt output from the EC325 PSU | No 230V supply | Work through the 230V checks above first. | DIY Safe |
N/A | No 12 volt output from the EC325 PSU | Charger not switched on | Turn the charger switch on - it will illuminate when active. | DIY Safe |
N/A | No 12 volt output from the EC325 PSU | Battery not connected and/or not charged | Fit a charged battery. | DIY Safe |
Recommended partAffiliate linksView partHideOnly if your leisure battery needs replacing - check the size, type and terminal layout of the one fitted now, and that your charger supports it, before ordering: Leisure batteries vary by vehicle (size, capacity and type - lead-acid, AGM, EFB or lithium). This is a widely used 100Ah EFB battery, not a documented exact match for your vehicle. Leisure battery (100Ah EFB)Yuasa L36-EFB 12V 100Ah Leisure Battery~£1384.3★ (119 ratings), sold by Amazon - established battery brand View on Amazon → | ||||
N/A | No 12 volt output from the EC325 PSU | Power switch on the control panel not switched on | Turn the power on at the control panel. | DIY Safe |
N/A | No 12 volt output from the EC325 PSU | Battery flat, or its fuse blown | Recharge the battery, check the fuses, and confirm charging voltage is actually present at the battery. | DIY Safe |
N/A | No 12 volt output from the EC325 PSU | A fuse has blown | Make sure none of the fuses have blown and each one matches the rating shown on the fuse table. | DIY Safe |
N/A | No 12 volt output from the EC325 PSU | Equipment switched off or unplugged | Check the equipment itself is switched on and properly connected to the 12V supply. | DIY Safe |
N/A | No 12 volt output from the EC325 PSU | PSU has overheated and shut down automatically | Reduce the load on the system and let the PSU cool down - it will restart on its own once it has. | DIY Safe |
N/A | No 12 volt output from the EC325 PSU | Some other fault | Contact your dealer. | Professional Intervention Required |
Auto-SleepersGas Supply System (Broadway, 2012 Model Year)
Gas Regulator / Supply5040 FAQs
Gas Supply System (Broadway, 2012 Model Year)
Gas Regulator / SupplyMaster Troubleshooting & Diagnostics Matrix
| Error Code / Indicator | Symptom / Meaning | Possible Cause | Step-by-Step DIY Fix | Suggested Actions |
|---|---|---|---|---|
N/A | Appliance will not light | No gas | Swap in a fresh cylinder, confirm it's turned on, and check the isolation valve is open. | DIY Safe |
N/A | Appliance will not light | Low battery (auto ignition) | Charge battery | DIY Safe |
N/A | Appliance lights but goes out immediately the FSD override is released | Flame supervision device (FSD) is not functioning correctly | Refer to dealer | Professional Intervention Required |
N/A | Odour | Gas leak | Shut down the gas supply at the cylinder without delay, and leave the system alone until it's been properly fixed. Should a cylinder appear to be leaking, relocate it - if it's safe to do so - well clear of anything that could ignite it, then get in touch with the site warden and/or your local gas supplier. | Professional Intervention Required |
N/A | Yellow flame | There isn't enough primary air reaching the burner - note that a little yellow tipping on the flame is normal and not a fault. | Refer to dealer | Professional Intervention Required |
N/A | Orange flame | Dust or dirt particles in the mixing tube are being carried through the burner ports. | Reduce the level of dust in the surrounding air. | DIY Safe |
N/A | Orange flame | Burner ports partially blocked | Refer to dealer | Professional Intervention Required |
N/A | Floating flame | Lack of secondary air | Make sure every vent is clear, including the vehicle's air inlet. | DIY Safe |
N/A | Floating flame | Blocked retention ports | Make sure the retention ports aren't blocked; on an oven, also confirm the flue way isn't obstructed. | DIY Safe |
Auto-SleepersHeating (Broadway, 2012 Model Year)
Heating System (Space/Water)6020 FAQs
Heating (Broadway, 2012 Model Year)
Heating System (Space/Water)Master Troubleshooting & Diagnostics Matrix
| Error Code / Indicator | Symptom / Meaning | Possible Cause | Step-by-Step DIY Fix | Suggested Actions |
|---|---|---|---|---|
N/A | Water heater does not operate on 230V | No power | Switch on isolator switch/check MCB is on | DIY Safe |
N/A | Water heater does not operate on 230V | Overtemperature trip activated | Reset the thermal cut-out, following the operating instructions. | DIY Safe |
N/A | Water Heater not operating/cuts out | Fuse 11 blown | Track down the fault and fit a replacement fuse of the identical rating. | DIY Safe |
Recommended partsAffiliate linksView 2 optionsHideCheck whether the blown fuse is a standard or a mini blade fuse (mini ones are roughly half the size), then choose the matching kit: This fault doesn't say which fuse rating has blown, only to replace it like-for-like. Both kits cover the common ratings (5A-30A) - match the rating printed on the blown fuse. Standard blade fusesCar Fuse Kit - 60pc Assorted Blade Fuses (5A-30A) with Storage Case and Fuse Puller~£5.994.5★ (1,500+ ratings), sold by KANGRUI, dispatched by Amazon - includes 15A blade fuses plus a puller and storage case View on Amazon →Mini blade fusesNilight 120pc Mini Blade Fuse Assortment (5A-30A, ATM/APM) with Fuse Puller~£5.244.5★ (2,500+ ratings), sold by Amazon - includes 15A mini blade fuses View on Amazon → | ||||
N/A | Water Heater not operating/cuts out | Low battery charge | Recharge battery | DIY Safe |
N/A | Water Heater not operating/cuts out | Unit fault | Refer to dealer | Professional Intervention Required |
N/A | No hot water (mains system) | Water heater tripped | Check and press re-set button | DIY Safe |
N/A | No hot water (gas system) | Gas module not lighting | Refer to dealer | Professional Intervention Required |
N/A | No hot water (gas system) | Igniter not working | Check 12V switched on | DIY Safe |
TrumaCP E Classic
Heating System (Space/Water)11140 FAQs
CP E Classic
Heating System (Space/Water)Technical Specifications
Master Troubleshooting & Diagnostics Matrix
| Error Code / Indicator | Symptom / Meaning | Possible Cause | Step-by-Step DIY Fix | Suggested Actions |
|---|---|---|---|---|
N/A | None of the LEDs light up, even with the appliance switched on and getting its operating voltage | The automatic restart lock has kicked in, e.g. following a power cut | Clear the fault by switching off, leaving it 5 seconds, then switching back on. | DIY Safe |
N/A | Nothing lights up when it's switched on | No operating voltage or appliance/vehicle fuse defective | Check the 12V battery voltage and charge if needed, check every electrical plug connection, and check/replace the appliance's or vehicle's fuse. | DIY Safe |
N/A | The green LED lights up once switched on, but the heater doesn't run | The control panel's temperature setting is below the current room temperature. | Turn the temperature setting up at the control panel. | DIY Safe |
Yellow LED flashes 1 x | Heater continues operating with risk of low voltage | Battery voltage has dropped below 10.4V (gas heater) or 11.5V (diesel heater) | Charge battery. For diesel heater, use electrical power from battery sparingly. | DIY Safe |
Yellow LED flashes 2 x | Heater not functioning due to low voltage or overvoltage | Battery voltage has dropped below 10.0V/10.2V, or risen above 16.4V (overvoltage) | Charge the battery, or fit a new one if it's old. For overvoltage, check the battery voltage itself along with whatever's supplying it (e.g. the charger). | DIY Safe |
Yellow LED flashes 3 x | Heater stops operating | Open window above cowl detected by window switch | Close the window. | DIY Safe |
Yellow LED flashes 4 x | The heater faults out after running for an extended period | Either it's in summer mode with an empty water container, the warm air outlets are blocked, or the circulated air intake is blocked | Switch the appliance off and let it cool, top up the boiler with water, check each outlet opening individually, and clear any blockage from the circulated air intake. | DIY Safe |
Yellow LED flashes 5 x | Heater indicates sensor fault | The room temperature sensor or its cable is faulty | Contact an authorised service agent. | Professional Intervention Required |
Yellow LED flashes 7 x | Heater indicates control panel fault | The control panel or its cable is faulty | Contact an authorised service agent. | Professional Intervention Required |
Yellow LED flashes 8 x | Heater indicates short circuit in FrostControl | The FrostControl heating element has short-circuited | Unplug the heating element from the electronic control unit and have a specialist fit a replacement. | DIY Check / Tech Fallback |
Yellow LED flashes 9 x | The heater cuts out roughly 30 seconds after switching on | Could be a closed gas cylinder/quick-acting valve, an empty gas cylinder, an iced-up gas pressure regulator, or gas with too high a butane content | Open the gas supply valves, swap in a fresh cylinder, fit an EisEx regulator, or switch to propane. | DIY Safe |
Red LED flashes between 1 and 8 times | Heater fault | Heater electronics fault | Determine the flashing code and contact an authorised service agent. | Professional Intervention Required |
N/A | The green LED stays lit after the heater is switched off | This is the after-run cycle, bringing the appliance's temperature down | Nothing's wrong - the after-run cycle switches off by itself within 5 minutes at most. | DIY Safe |
N/A | Room heating doesn't respond straight away to an adjustment | This is the after-run cycle, bringing the appliance's temperature down | Nothing's wrong - the after-run cycle switches off by itself within 5 minutes at most. | DIY Safe |
N/A | Both the green and red LEDs light up once switched on | Faulty electronics | Contact an authorised service agent. | Professional Intervention Required |
Red LED flashes 6 x | Diesel heater fails to start | There isn't enough fuel - the tank wasn't filled enough, has run dry, and/or the vehicle is parked on a slope | Refill the tank, then bleed the fuel line as covered in the initial start-up instructions. | DIY Safe |
Auto-SleepersLighting (Broadway, 2012 Model Year)
Lighting2000 FAQs
Lighting (Broadway, 2012 Model Year)
LightingMaster Troubleshooting & Diagnostics Matrix
| Error Code / Indicator | Symptom / Meaning | Possible Cause | Step-by-Step DIY Fix | Suggested Actions |
|---|---|---|---|---|
N/A | Lights dull/only one tube illuminating | Low battery charge | Check battery | DIY Safe |
N/A | Lights dull/only one tube illuminating | Faulty light unit/tube | Replace/Check | DIY Safe |
Auto-SleepersRefrigeration & Cooling (Broadway, 2012 Model Year)
Fridge / Freezer4061 FAQ
Refrigeration & Cooling (Broadway, 2012 Model Year)
Fridge / FreezerMaster Troubleshooting & Diagnostics Matrix
| Error Code / Indicator | Symptom / Meaning | Possible Cause | Step-by-Step DIY Fix | Suggested Actions |
|---|---|---|---|---|
N/A | Refrigerator does not operate on 230V | Switch on refrigerator thermostat dial not 'on' | Check position of thermostat dial | DIY Safe |
N/A | Refrigerator does not operate on 230V | Element fault | Refer to dealer | Professional Intervention Required |
N/A | Fridge gas ignition not operating | Fuse 11 blown | Track down the fault and fit a replacement fuse of the identical rating. | DIY Safe |
Recommended partsAffiliate linksView 2 optionsHideCheck whether the blown fuse is a standard or a mini blade fuse (mini ones are roughly half the size), then choose the matching kit: This fault doesn't say which fuse rating has blown, only to replace it like-for-like. Both kits cover the common ratings (5A-30A) - match the rating printed on the blown fuse. Standard blade fusesCar Fuse Kit - 60pc Assorted Blade Fuses (5A-30A) with Storage Case and Fuse Puller~£5.994.5★ (1,500+ ratings), sold by KANGRUI, dispatched by Amazon - includes 15A blade fuses plus a puller and storage case View on Amazon →Mini blade fusesNilight 120pc Mini Blade Fuse Assortment (5A-30A, ATM/APM) with Fuse Puller~£5.244.5★ (2,500+ ratings), sold by Amazon - includes 15A mini blade fuses View on Amazon → | ||||
N/A | Fridge gas ignition not operating | Ignition control switch fault | Refer to dealer | Professional Intervention Required |
N/A | Fridge ignition switch flashes but gas does not ignite | Fault on fridge unit | Refer to dealer | Professional Intervention Required |
N/A | You can hear the ignition sparking, but the fridge switch itself doesn't flash. | Faulty fridge ignition switch | Refer to dealer | Professional Intervention Required |
N/A | Fridge does not operate on 12V when engine is running | Fuse 3 blown | Track down the fault and fit a replacement fuse of the identical rating. | DIY Safe |
Recommended partsAffiliate linksView 2 optionsHideCheck whether the blown fuse is a standard or a mini blade fuse (mini ones are roughly half the size), then choose the matching kit: This fault doesn't say which fuse rating has blown, only to replace it like-for-like. Both kits cover the common ratings (5A-30A) - match the rating printed on the blown fuse. Standard blade fusesCar Fuse Kit - 60pc Assorted Blade Fuses (5A-30A) with Storage Case and Fuse Puller~£5.994.5★ (1,500+ ratings), sold by KANGRUI, dispatched by Amazon - includes 15A blade fuses plus a puller and storage case View on Amazon →Mini blade fusesNilight 120pc Mini Blade Fuse Assortment (5A-30A, ATM/APM) with Fuse Puller~£5.244.5★ (2,500+ ratings), sold by Amazon - includes 15A mini blade fuses View on Amazon → | ||||
N/A | Fridge does not operate on 12V when engine is running | Fuse 7 in EM50 interface box blown | Track down the fault and fit a replacement fuse of the identical rating. | DIY Safe |
Recommended partsAffiliate linksView 2 optionsHideCheck whether the blown fuse is a standard or a mini blade fuse (mini ones are roughly half the size), then choose the matching kit: This fault doesn't say which fuse rating has blown, only to replace it like-for-like. Both kits cover the common ratings (5A-30A) - match the rating printed on the blown fuse. Standard blade fusesCar Fuse Kit - 60pc Assorted Blade Fuses (5A-30A) with Storage Case and Fuse Puller~£5.994.5★ (1,500+ ratings), sold by KANGRUI, dispatched by Amazon - includes 15A blade fuses plus a puller and storage case View on Amazon →Mini blade fusesNilight 120pc Mini Blade Fuse Assortment (5A-30A, ATM/APM) with Fuse Puller~£5.244.5★ (2,500+ ratings), sold by Amazon - includes 15A mini blade fuses View on Amazon → | ||||
N/A | Fridge does not operate on 12V when engine is running | Fault on fridge relay | Refer to dealer | Professional Intervention Required |
N/A | Fridge does not operate on 12V when engine is running | Fault on fridge unit | Refer to dealer | Professional Intervention Required |
Frequently Asked Questions
Q: Does the refrigerator need a winter cover?
Not using the fridge for a while? Clear out the food, turn it off, give it a wipe down and shut off its gas supply. Prop the door open on its storage catch to let air circulate inside, and pop the winter cover over the outside ventilation grill.
ThetfordN97 Refrigerator (as fitted to Auto-Sleepers Peugeot Coachbuilt motorhomes, 2009-2017)
Fridge / Freezer7220 FAQs
N97 Refrigerator (as fitted to Auto-Sleepers Peugeot Coachbuilt motorhomes, 2009-2017)
Fridge / FreezerTechnical Specifications
Master Troubleshooting & Diagnostics Matrix
| Error Code / Indicator | Symptom / Meaning | Possible Cause | Step-by-Step DIY Fix | Suggested Actions |
|---|---|---|---|---|
N/A | Refrigerator will not work on gas | The gas bottle is empty, or the gas bottle valve or an isolation valve is closed. | Replace the gas bottle if empty, and open the gas bottle valve and any closed isolation valves. | DIY Safe |
N/A | Refrigerator will not work on 12V DC | The 12V fuse (fuse 3) is defective, or the habitation battery is flat. | Fit a new fuse (fuse number 3). Test the habitation battery and charge it if needed. | DIY Safe |
N/A | Refrigerator does not refrigerate sufficiently | Insufficient ventilation through the grills, the thermostat set too low, ice build-up on the condenser, too much food loaded in at once, a dirty gas burner, or the door not closing properly. | Check the ventilation grills aren't covered, increase the thermostat setting, check the door shuts properly and defrost the fridge if there's excess ice, let hot food cool before loading it in, have the gas burner cleaned, and check the door closing mechanism. | DIY Safe |
1, 2, 3, 4, 6, 7, 12, 14 | Refrigerator LCD displays fault code 1, 2, 3, 4, 6, 7, 12 or 14 | An internal AC/DC heater, gas-terminal or control-board fault with no user-serviceable cause. | Contact your dealer or a Thetford Service Centre directly. | Professional Intervention Required |
5 | Refrigerator LCD displays fault code 5 (senses a flame when gas should be off) | Flame sensor fault. | Contact your dealer or a Thetford Service Centre directly. | Professional Intervention Required |
8 | Refrigerator LCD displays fault code 8 (AC mains supply 20% below nominal) | The controls are in manual AC mode but there isn't enough power available. | Check that 230V is plugged in - if it is, the voltage supply itself is too low. Contact the site owner. | DIY Safe |
9 | Refrigerator LCD displays fault code 9 (gas lock-out, flame fails to ignite within 30 seconds) | The controls are in manual gas mode but the flame has failed to ignite - often an empty gas cylinder or a closed isolation valve. | Check whether the gas cylinder is empty or an isolation valve is closed. Select another energy source, or reset the refrigerator 3 or 4 times in gas mode until the flame ignites. Contact your dealer or a Thetford Service Centre if the problem persists. | DIY Check / Tech Fallback |
10 | Refrigerator LCD displays fault code 10 (no 'engine running' signal in manual DC mode) | The controls are in manual DC mode but the engine is not running - the refrigerator can only cool on 12V while the engine runs. | Start the engine or select a different energy source. | DIY Safe |
11 | Refrigerator LCD displays fault code 11 (no energy source available in AUTO mode) | The controls are in AUTO mode but no energy source is currently available. | Start the engine, connect the 230V supply, or open the gas supply, then reset the refrigerator by switching it off and on again. | DIY Safe |
13 | Refrigerator LCD displays fault code 13 (control switches automatically to Backup mode) | The thermistor has failed, often because its connector is not correctly plugged in. | Check that the connector above the fin on the inside of the cabinet is correctly plugged in. If it is, contact your dealer or a Thetford Service Centre. | DIY Check / Tech Fallback |
18 | Refrigerator LCD displays fault code 18 on start-up | Normal start-up behaviour - all LCD segments lighting briefly is not a fault. | Wait a few seconds for the refrigerator to start up normally. No action needed. | DIY Safe |
Auto-SleepersSecurity & Alarms (Broadway, 2012 Model Year)
Vehicle Security / Alarm System0001 FAQ
Security & Alarms (Broadway, 2012 Model Year)
Vehicle Security / Alarm SystemFrequently Asked Questions
Q: What do I do if my Auto-Sleeper is stolen?
If your vehicle turns up stolen - whether you spot it yourself or the Control Centre lets you know - get a crime reference number from the police first, then pass it on to the Control Centre using the details on your HAL-Locate registration card, and they'll work directly with the police to track it down and get it back.
Keep the leisure battery well charged, since the system needs that to work properly, and remember the HAL-Locate service itself is on an annual subscription that kicks in after your first 2 years of ownership. Selling the vehicle or changing your contact details (mobile number included)? Let the HAL-Locate support team know on 0844 3576269.
Auto-SleepersWater System (Broadway, 2012 Model Year)
Water System Component22131 FAQ
Water System (Broadway, 2012 Model Year)
Water System ComponentMaster Troubleshooting & Diagnostics Matrix
| Error Code / Indicator | Symptom / Meaning | Possible Cause | Step-by-Step DIY Fix | Suggested Actions |
|---|---|---|---|---|
N/A | Water pump will not run (Water system) | — | Make sure the plug and socket contacts are clean and seated properly, and check the wiring connections. | DIY Safe |
N/A | The water pump switches on and off even with the tap shut (Water system) | — | Look for air or water leaks at the taps and pipework, and readjust the pressure switch. | DIY Safe |
N/A | The water pump motor keeps running continuously and won't stop (Water system) | — | Confirm the container actually has water in it - a battery reading below roughly 10.5V can also be the cause. Adjust the pressure switch and/or recharge the battery, and check every pipework connection. A Whale Tiptoe Pump, fitted in-line alongside the submersible pump, can serve as a manual backup. | DIY Safe |
N/A | Water pump doesn't switch off when taps are closed, or pulses on/off when taps are fully open (Water system) | — | To readjust the pressure switch: with the system fully primed and every tap shut, wind the screw clockwise, in a right-hand direction, until the pump kicks in; open whichever tap sits furthest away and let it run smoothly, then shut it; slowly back the screw off anti-clockwise until the pump cuts out, then continue a further half-turn (180 degrees); finally check every tap individually operates correctly. | DIY Safe |
N/A | Water pump runs continuously even with taps closed (Water system) | Present voltage is significantly lower than when last adjusted, or the water container is empty - risk of pump failure and a flat battery | Re-adjust the pressure switch or refill the water container. | DIY Safe |
N/A | The water pump won't run at all, even though the fuse is intact and connections are sound (Water system) | This is most often down to the pump having run continuously for too long. | Replace the pump and readjust the pressure switch. | DIY Safe |
Recommended partAffiliate linksView partHideAuto-Sleepers fits a Whale submersible pump in this water system but doesn't name the exact model, so this is the standard current Whale replacement rather than a documented exact match - check the pump fitted in your tank before ordering. Whale GP1002 Standard 12V Submersible Water Pump, 10 Litres~£19.914.6★ (1,000+ ratings), Whale-branded, sold by Serenity Garden Ltd, dispatched by Amazon View on Amazon → | ||||
N/A | The water pump cycles on and off repeatedly, giving a pulsing flow at the tap, or the water temperature won't stay constant (Water system) | The current voltage has risen well above what it was when the switch was last set. | Readjust the pressure switch - if that doesn't resolve it, fit a Whale Surge Damper. | DIY Safe |
N/A | The water pump is very noisy but isn't actually pumping any water (Water system) | Pump is air-locked after the water container was refilled | Unplug the pump from its socket to let it flood, then reconnect. Always unplug the pump before placing it in the container when refilling, then reconnect. | DIY Safe |
N/A | Water pump not operating | Switch on panel 'off' | Switch it 'on' | DIY Safe |
N/A | Water pump not operating | Pressure switch on pump not operating | Refer to dealer | Professional Intervention Required |
N/A | Water pump not operating | Fuse 4 blown | Track down the fault and fit a replacement fuse of the identical rating. | DIY Safe |
Recommended partsAffiliate linksView 2 optionsHideCheck whether the blown fuse is a standard or a mini blade fuse (mini ones are roughly half the size), then choose the matching kit: This fault doesn't say which fuse rating has blown, only to replace it like-for-like. Both kits cover the common ratings (5A-30A) - match the rating printed on the blown fuse. Standard blade fusesCar Fuse Kit - 60pc Assorted Blade Fuses (5A-30A) with Storage Case and Fuse Puller~£5.994.5★ (1,500+ ratings), sold by KANGRUI, dispatched by Amazon - includes 15A blade fuses plus a puller and storage case View on Amazon →Mini blade fusesNilight 120pc Mini Blade Fuse Assortment (5A-30A, ATM/APM) with Fuse Puller~£5.244.5★ (2,500+ ratings), sold by Amazon - includes 15A mini blade fuses View on Amazon → | ||||
N/A | Continuous running of water pump | No water | Fill tank | DIY Safe |
N/A | Continuous running of water pump | Major leak | Turn the system off straight away and check it over. | DIY Safe |
N/A | Intermittent operation of water pump | Minor leak in water system | Check push fit joints | DIY Safe |
N/A | Intermittent operation of water pump | Water pump pressure release valve reasserting itself | Nothing to do - this is simply how the pump is designed to behave. | DIY Safe |
N/A | Water pump does not operate | Fuse 4 blown | Track down the fault and fit a replacement fuse of the identical rating. | DIY Safe |
Recommended partsAffiliate linksView 2 optionsHideCheck whether the blown fuse is a standard or a mini blade fuse (mini ones are roughly half the size), then choose the matching kit: This fault doesn't say which fuse rating has blown, only to replace it like-for-like. Both kits cover the common ratings (5A-30A) - match the rating printed on the blown fuse. Standard blade fusesCar Fuse Kit - 60pc Assorted Blade Fuses (5A-30A) with Storage Case and Fuse Puller~£5.994.5★ (1,500+ ratings), sold by KANGRUI, dispatched by Amazon - includes 15A blade fuses plus a puller and storage case View on Amazon →Mini blade fusesNilight 120pc Mini Blade Fuse Assortment (5A-30A, ATM/APM) with Fuse Puller~£5.244.5★ (2,500+ ratings), sold by Amazon - includes 15A mini blade fuses View on Amazon → | ||||
N/A | Water gauge does not operate | Probe fault | Refer to dealer (check probe connections) | DIY Check / Tech Fallback |
N/A | Slow drainage from sink/shower tray | Blocked breathers in waste tank | Drop tank and clear breathers | DIY Safe |
N/A | Tip-up handbasin slow to drain | Blocked drain hole | Remove basin and clear | DIY Safe |
N/A | Unsatisfactory operation of water pump | Filter blocked | Clean filter | DIY Safe |
N/A | Pump feed does not operate (PSU control panel) | A fuse has blown | Replace with the correct-rated fuse, per the fuse table. | DIY Safe |
Recommended partsAffiliate linksView 2 optionsHideCheck whether the blown fuse is a standard or a mini blade fuse (mini ones are roughly half the size), then choose the matching kit: This fault doesn't say which fuse rating has blown, only to replace it like-for-like. Both kits cover the common ratings (5A-30A) - match the rating printed on the blown fuse. Standard blade fusesCar Fuse Kit - 60pc Assorted Blade Fuses (5A-30A) with Storage Case and Fuse Puller~£5.994.5★ (1,500+ ratings), sold by KANGRUI, dispatched by Amazon - includes 15A blade fuses plus a puller and storage case View on Amazon →Mini blade fusesNilight 120pc Mini Blade Fuse Assortment (5A-30A, ATM/APM) with Fuse Puller~£5.244.5★ (2,500+ ratings), sold by Amazon - includes 15A mini blade fuses View on Amazon → | ||||
N/A | Pump feed does not operate (PSU control panel) | Pump switched off | Press the pump button on the control panel to switch it back on. | DIY Safe |
N/A | Pump feed does not operate (PSU control panel) | Pump setting incorrect | The control panel governs the pump's feed, both internal and external, as one setting - if it needs changing, that's a job for your dealer, so confirm it matches what you actually need. | Professional Intervention Required |
N/A | Pump feed does not operate (PSU control panel) | A fuse has blown | Replace with the correct-rated fuse. | DIY Safe |
Recommended partsAffiliate linksView 2 optionsHideCheck whether the blown fuse is a standard or a mini blade fuse (mini ones are roughly half the size), then choose the matching kit: This fault doesn't say which fuse rating has blown, only to replace it like-for-like. Both kits cover the common ratings (5A-30A) - match the rating printed on the blown fuse. Standard blade fusesCar Fuse Kit - 60pc Assorted Blade Fuses (5A-30A) with Storage Case and Fuse Puller~£5.994.5★ (1,500+ ratings), sold by KANGRUI, dispatched by Amazon - includes 15A blade fuses plus a puller and storage case View on Amazon →Mini blade fusesNilight 120pc Mini Blade Fuse Assortment (5A-30A, ATM/APM) with Fuse Puller~£5.244.5★ (2,500+ ratings), sold by Amazon - includes 15A mini blade fuses View on Amazon → | ||||
N/A | Pump feed does not operate (PSU control panel) | Pump switched off | Press the tap-symbol pump button on the control panel to switch it back on. | DIY Safe |
N/A | Pump feed does not operate (PSU control panel) | Pump setting incorrect | The control panel governs the pump's feed, both internal and external, as one setting - if it needs changing, that's a job for your dealer, so confirm it matches what you actually need. | Professional Intervention Required |
Frequently Asked Questions
Q: How do I winterise the water system before storing the vehicle for winter?
Open the drain valve next to the water heater, and leave the fresh and waste water tank drain taps open too. Open every internal tap, then run the pump until it stops delivering anything. Go for a short spin with those drain taps still open - it helps shift the last of the water out of the tanks and pipework. Pull the sink plugs so the system can breathe, give the waste tank a thorough flush to shift any debris, finish with a flush of mild disinfectant, and leave the drain tap open.
WhaleGP1309
Water Pump0306 FAQs
GP1309
Water PumpTechnical Specifications
Master Troubleshooting & Diagnostics Matrix
| Error Code / Indicator | Symptom / Meaning | Possible Cause | Step-by-Step DIY Fix | Suggested Actions |
|---|---|---|---|---|
N/A | The pump is slow to prime | The cup washer may be worn, or the valves are not seating properly. | Check the cup washer and valves, cleaning or replacing them as necessary using Service Kit AK1304 (also covers the Mk3 pump). If the issue remains unresolved, contact an authorised service agent. | DIY Check / Tech Fallback |
N/A | The pump will not pump at all | The suction line isn't submerged in water, the hose connections are loose or letting in air, the internal washers are worn, or the outlet tap/faucet is closed. | Check that the suction line is in the water, make sure all hose connections are secure with no air leaks, inspect the washers and replace them if worn using Service Kit AK1304, and confirm the outlet tap or faucet is open to let water through. If the issue remains unresolved, contact an authorised service agent. | DIY Check / Tech Fallback |
N/A | The pump is leaking | The gland washer is likely worn. | Replace the gland washer using Service Kit AK1304. If the issue remains unresolved, contact an authorised service agent. | DIY Check / Tech Fallback |
Frequently Asked Questions
Q: How do I lock the Tiptoe pump away when it's not in use?
Push the plunger fully down and twist it clockwise - it locks flush with the floor. To use it again, twist the plunger anti-clockwise to release it, then pump with your foot: harder for full flow, gently for a more controlled flow.
Q: Can the Tiptoe pump be used as a backup for an electric water pump?
Yes, as long as the system isn't pressurised - fit the Tiptoe pump between the inline electric pump and the water supply so it can act as a manual backup if the electric pump fails.
Q: What does the Whale Superfil pump kit do?
If you have a Whale Easi-Slide socket with a 12V connection, the Superfil kit lets you pump water into your onboard tank from an external container such as an Aquaroll or jerry can - so running out of water doesn't mean packing up to drive to the nearest tap.
Q: Which is better - a submersible pump or a pressure pump?
It depends what you need. Whale's submersible pumps are simple, compact, quiet and inexpensive, and come in three flow rates: standard (10.3 litres/min), premium (13.2 litres/min) and high (15.8 litres/min). The Watermaster Onboard pressure pump (8 litres/min) is fitted inside the vehicle and gives a smooth, steady flow; it has its own built-in pressure switch, can run dry without damage, and is built to last.
Q: Is a submersible pump quieter than a pressure pump?
Yes. A submersible pump is a centrifugal design with an impeller as its only moving part, so it runs very quietly. A pressure pump is simple to fit and very dependable, but it's noisier.
Q: When would I need a pressure switch or a surge damper?
A Whale pressure switch is for vehicles fitted with a submersible pump: it senses the drop in water pressure when a tap is opened and turns the pump on. Because it works with any tap, you aren't restricted to taps with built-in microswitches.
Auto-SleepersBlinds & Flyscreens (Broadway, 2012 Model Year)
Blind / Window Covering0100 FAQs
Blinds & Flyscreens (Broadway, 2012 Model Year)
Blind / Window CoveringMaster Troubleshooting & Diagnostics Matrix
| Error Code / Indicator | Symptom / Meaning | Possible Cause | Step-by-Step DIY Fix | Suggested Actions |
|---|---|---|---|---|
N/A | Concertina blind or flyscreen has become stiff and difficult to operate | The mechanism has dried out or picked up dust/grit over time - these units need only light, occasional lubrication. | Apply a light lubricant to the mechanism. Avoid cleaning solvents or aerosols on the blind material itself, as it's a paper-type fabric that these can damage. If the problem persists, contact your Auto-Sleepers dealer. | DIY Check / Tech Fallback |