Technical Specifications

Operating Voltage12V DC
Power ConsumptionTruma VarioHeat eco: 0.65 / 2.75 A; Truma VarioHeat comfort: 0.65 / 2.75 / 5.4 A
Gas Or PressureLiquefied gas (propane / butane) at 30 mbar
Fuse RatingsAppliance fuse (F1): 10 AF – quick – (EN 60127-2-3)
Dimensions Cutout380 x 248 x 123 mm

Master Troubleshooting & Diagnostics Matrix

Error Code / IndicatorSymptom / MeaningPossible CauseStep-by-Step DIY FixSuggested Actions
N/A
None of the LEDs light up, even with the appliance switched on and getting its operating voltage
The automatic restart lock has kicked in, e.g. following a power cut
Reset the fault by switching off, waiting 5 seconds, then switching back on
DIY Safe
N/A
Nothing lights up when it's switched on
No operating voltage
Check the 12V battery voltage, charge if needed, and check the plug connections
DIY Safe
N/A
Nothing lights up when it's switched on
The appliance's or vehicle's fuse is faulty
Check the appliance's or vehicle's fuse and replace it if needed
DIY Safe
N/A
The green LED lights up once switched on, but the heater doesn't run
The control panel's temperature is set below the room temperature
Turn the room temperature up at the control panel
DIY Safe
Red LED flashes 1 x
After running for a while, the heater switches to fault
The gas cylinder or its quick-acting valve is closed.
Check and/or open the gas supply valves
DIY Safe
Red LED flashes 1 x
After running for a while, the heater switches to fault
Gas cylinder empty
Replace the gas cylinder
DIY Safe
Red LED flashes 1 x
After running for a while, the heater switches to fault
The gas pressure regulator has iced up
Use EisEx regulator heater
DIY Safe
Red LED flashes 1 x
After running for a while, the heater switches to fault
The gas cylinder's butane content is too high
Switch to propane instead - butane doesn't heat well, especially below 10°C
DIY Safe
Red LED flashes 1 x
After running for a while, the heater switches to fault
The combustion air inlet or exhaust outlet is blocked
Check the openings for anything blocking them (slush, ice, leaves, etc.) and clear it away.
DIY Safe
Red LED flashes 2 x
Heater fault
Heater internal fault
Contact an authorised service agent
Professional Intervention Required
Red LED flashes 3 x
After switching on, the red LED flashes 3 times while the green LED stays lit
Low voltage risk - battery voltage has dropped below 10.4V
Charge battery
DIY Safe
Red LED flashes 3 x
After switching on, the red LED flashes 3 times while the green LED stays lit
Low voltage - battery voltage has dropped below 10V
Charge the battery, and fit a new one if it's old
DIY Safe
Red LED flashes 3 x
After switching on, the red LED flashes 3 times while the green LED stays lit
Overvoltage > 16.4 V
Check the battery voltage and whatever's supplying it, such as the charger
DIY Safe
Red LED flashes 4 x
Open window above cowl
Window switch triggered by open window near cowl
Close windows
DIY Safe
Red LED flashes 5 x
Air flow obstruction
Warm air outlets or circulated air intake blocked
Remove blockage
DIY Safe
Red LED flashes 6 x
Motor wear limit reached
The motor's wear limit is coming up soon
Contact an authorised service agent
Professional Intervention Required