Truma • Water Heating

Truma Ultrastore Water Heater

Official technical documentation and workshop diagnostics for Storage Water Heater.

View official manual on manufacturer's site ↗

Technical Specifications

TypeLiquid gas (LPG) operated storage water heater with an additional 230V electric heating element
Max Water Pressure2.8 bar (use a pressure reducer when connected to a central/mains water supply)

Master Troubleshooting & Diagnostics Matrix

Error Code / IndicatorSymptom / MeaningStep-by-Step DIY FixSuggested Actions
N/A
When switching on, the heater does not operate (gas operation)
Possible Cause: No 12V supply, or a window above the cowl is open.
Check the power supply (operating voltage minimum 10.5V). Check the water heater fuse. Close any windows above the cowl.DIY Safe
N/A
When switching on, the heater does not operate and the red lamp lights up (gas operation)
Possible Cause: Cowl cover fitted, air in the gas supply, no gas supply, or incorrect gas pressure.
Remove the cowl cover and/or clear any obstruction. Check gas valves and the gas bottle. To unlock (and purge air), switch off the appliance, wait 5 minutes, and switch on again.DIY Safe
N/A
Heater operates for a prolonged time and then the red lamp lights up (gas operation)
Possible Cause: Over-temperature thermostat has operated.
Check water content and refill if required (close the drain valve first). To unlock, switch off the appliance, wait 5 minutes, and switch on again.DIY Safe
N/A
When switching on, the heater does not operate (electrical operation)
Possible Cause: No 230V supply voltage, or the over-temperature thermostat has operated.
Connect the vehicle to the site supply and/or check the residual current circuit breaker. Check water content and refill if required (close the drain valve first). The electrical heating element has an excess-temperature cut-out - in the event of a fault, switch off at the control panel, wait 5 minutes, then switch on again.DIY Safe
N/A
Water drips from the safety/drain valve
Possible Cause: Water pressure too high.
Check water pressure (max. 2.8 bar) - use a pressure reducer when connected to a central water supply.DIY Safe
N/A
When opening the cold water tap, hot water comes out
Possible Cause: Hot water flows back through the cold water supply.
Fit a non-return valve in the cold water supply (refer to installation instructions). If the fault persists, contact Truma Service.DIY Check / Tech Fallback

Also Fitted In