Technical Specifications

Operating Voltage12V DC / 230V AC
Power ConsumptionHeater + water heater: C 4002: 0.2 – 5.6 A (average power consumption 1.3 A), C 6002: 0.2 – 5.6 A (average power consumption 1.4 A); Heating up of water heater: 0.4 A; Stand-by: 0.001 A; Electrical safety/drain valve: 0.035 A
Gas Or PressureLiquid gas (propane/butane), 30 mbar
Fuse RatingsDevice fuse: 6.3 AT (slow), Control panel fuse (F3): 1.6 AT (slow)

Master Troubleshooting & Diagnostics Matrix

Error Code / IndicatorSymptom / MeaningPossible CauseStep-by-Step DIY FixSuggested Actions
N/A
Switching on (winter or summer operation) lights no control lamp.
Could be a faulty appliance or vehicle fuse, an open window above the cowl (window switch), or low battery voltage.
Charge the 12V battery, check every electrical plug connection and fuse, and close the window.
DIY Safe
N/A
Switched on from the ZUC timer, the green indicator lamp lights but the heater won't run.
A window above the cowl is open (window switch).
Close the window.
DIY Safe
N/A
The red monitor lamp flashes once the heating system is switched on.
The battery voltage has dropped below 10.5V.
Charge the battery.
DIY Safe
N/A
Around half a minute after the heating is turned on, the red monitor lamp comes on and doesn't go out.
The gas cylinder or its quick-closure valve is shut, or the air feed is interrupted.
Check the gas feed and check the cowl isn't covered - on a boat, make sure the deck cowl is open.
DIY Safe
N/A
After running for a time, the heating goes into Fault mode.
Could be blocked hot-air outlets, an iced-up gas regulator, or gas with too high a butane content.
Check each outlet aperture individually, fit a de-icing controller (EisEx), and switch to propane - butane doesn't heat well, especially below 10°C.
DIY Safe
N/A
Switching on (230V electrical operation) lights no control lamp.
No supply voltage.
Check the 230V supply voltage and its fuses.
DIY Safe
N/A
The electrical safety/drain valve opens whenever the heating is turned off.
The outside temperature is below 4°C, or there's no 12V supply reaching the drain valve.
Switch the heating on - below roughly 4°C the drain valve opens automatically. Check the 12V supply voltage and fuses.
DIY Safe
N/A
The electrical safety/drain valve won't close any more, or is dripping water.
Could be the outside temperature dropping below 8°C, no 12V supply at the drain valve, or excessive water pressure.
Switch the heating on - without it running, the drain valve won't close again until temperatures climb above 8°C. Check the 12V supply and fuses, and check the pump pressure stays under 2.8 bar, fitting a pressure reducer if it's on mains water. Contact an authorised service agent if this doesn't resolve it.
DIY Check / Tech Fallback

Frequently Asked Questions

Q: Can the heating be operated without water in the boiler?

Yes - it's fine to run it with or without water content, whatever the mode.

Q: Why does the electrical safety/drain valve open by itself?

At temperatures below 4°C at the valve, or when the system loses 12V power, the safety valve opens automatically to drain the boiler and prevent frost damage.

Q: How do I fill the water boiler?

Close the safety/drain valve by lifting the control knob to position 'm', turn on the water pump power, and open the hot water taps until water flows continuously without air.

Q: Can I use the hot water for drinking?

No, the water in the boiler is not drinking water.