Truma • Heating & Water

Truma Mover SR Version 2

Official technical documentation and workshop diagnostics for Mover SR.

View official manual on manufacturer's site ↗

Technical Specifications

Operating Voltage12 V DC
Power ConsumptionApprox. 20 A on average, Maximum 120 A

Master Troubleshooting & Diagnostics Matrix

Error Code / IndicatorSymptom / MeaningPossible CauseStep-by-Step DIY FixSuggested Actions
N/A
The LED is off with no audio signal
System is switched off or remote control batteries are discharged or missing.
Check the remote control's batteries and replace them if needed.
DIY Safe
N/A
The LED flashes for roughly 10 seconds after switching on, then goes off again
The radio link to the control unit can't be established.
Confirm the control unit is powered, then reset it by disconnecting the battery for around 10 seconds. Contact an authorised service agent if this doesn't fix it.
DIY Check / Tech Fallback
N/A
LED flashing every 3 seconds
Caravan battery charge is weak.
Finish manoeuvring as soon as you can, then charge the battery.
DIY Safe
N/A
The LED flashes 5 times a second (5Hz)
Caravan battery voltage is low (below approximately 11 V).
Movement is locked out until the battery voltage recovers above roughly 11V, either on its own or by charging.
DIY Safe
N/A
The LED flashes roughly twice a second (2Hz)
Overvoltage or overtemperature condition.
Switch the remote control off and back on. If it's an overtemperature issue, wait for the cooling-off period to finish.
DIY Safe