Truma • Water Heater

Truma Electric water heater

The Truma Electric Water Heater (BE 14) uses a 230 V, 850 W electric heating element to quickly heat up 14 liters of water for caravans and motorhomes. It features built-in safety controls, including an over-temperature limit and a safety/drain valve to protect against freezing damage.

Note: Information translated from the Turkish edition of the manual - we couldn't find an English edition.

View official manual on manufacturer's site ↗

Technical Specifications

Operating Voltage230 V ~, 50 Hz
Power Consumption3.7 A (850 W)
Gas Or Pressuremax. 2.8 bar (pump pressure) / max. 4.5 bar (system pressure)
Dimensions CutoutHeight: 295 mm, Width: 405 mm

Master Troubleshooting & Diagnostics Matrix

Error Code / IndicatorSymptom / MeaningPossible CauseStep-by-Step DIY FixSuggested Actions
N/A
Water is not heating.
No operating voltage.
Restore the power supply.
DIY Safe
N/A
Water is not heating.
Operation without water; the overheating safety switch has shut off the heater.
Switch off the appliance, wait 10 minutes, fill the water system, and switch the appliance back on.
DIY Safe
N/A
Extremely long heating time.
Water tank is scaled up.
Descale the water system (see maintenance instructions).
DIY Safe
N/A
Water runs away – boiler cannot be filled.
Safety/drain valve is open.
Close the safety/drain valve.
DIY Safe
N/A
Boiler cannot be drained even though the safety/drain valve is open.
The drainage outlet of the safety/drain valve is blocked.
Check the opening for any debris (such as slush, ice, or leaves) and clean the opening if necessary.
DIY Safe
N/A
Boiler cannot be drained even though the safety/drain valve is open.
The ventilation hose is blocked.
Check the hose opening (refer to the upper section).
DIY Safe
N/A
Water is dripping from the drainage outlet of the safety/drain valve.
The elbow fitting on the boiler is bent.
Check the hose for any kinks and straighten the hose.
DIY Safe
N/A
Water is dripping from the drainage outlet of the safety/drain valve.
Water pressure is too high.
Check the pump pressure (max. 2.8 bar). When connecting to a central water supply (country or city connection), a pressure reducer must be used to prevent pressures above 2.8 bar from developing in the boiler. If these steps do not resolve the fault, contact an authorised service agent.
DIY Check / Tech Fallback

Frequently Asked Questions

Q: Can the Truma electric boiler be operated with a timer?

No, the boiler cannot be operated with a timer.

Q: How do I reset the over-temperature safety fuse if the boiler was run dry?

Allow the device to cool down below 24 °C, switch it to "Off" (Closed), and then back to "On" (Open).

Q: What should I do to winterize or prevent frost damage?

Disconnect the water pump, open all hot water taps in the bathroom and kitchen, and open the safety/drain valve into the vertical position to drain all water out directly.