Truma Combi D E Next Generation
Official technical documentation and workshop diagnostics for Combi D E.
View official manual on manufacturer's site ↗Technical Specifications
Operating Voltage12V DC / 230V AC
Power Consumption0.4 – 8.1 A (12V), 900W / 1800W (230V)
Gas Or Pressuremax. 2.8 bar (Pump pressure), max. 4.5 bar (System pressure)
Dimensions Cutout450 x 510 x 300 mm
Master Troubleshooting & Diagnostics Matrix
| Error Code / Indicator | Symptom / Meaning | Possible Cause | Step-by-Step DIY Fix | Suggested Actions |
|---|---|---|---|---|
N/A | The water's taking a really long time to heat up | Water container furred | Descale the water system in accordance with the maintenance instructions. | DIY Safe |
N/A | Water's running straight back out - the water container won't fill | Safety / drain valve open | Close the safety / drain valve. | DIY Safe |
N/A | The water container won't drain, even with the safety/drain valve open | Either the safety/drain valve's drainage socket is blocked, or a water pipe has frozen | Check opening for dirt such as slush, ice, or leaves and remove if necessary, or thaw the water pipe. | DIY Safe |
N/A | Water's dripping or flowing from the safety/drain valve's drainage socket | Water pressure too high | Check the pump pressure stays under 2.8 bar, and fit a pressure reducer if it's connected to mains water. | DIY Safe |
N/A | The FrostControl opens after the heater's been switched off | Below roughly 3°C, the FrostControl opens on its own | Switch the heater on - with it off, the FrostControl won't close again until the temperature climbs to around 7°C or above, unless a FrostControl heating element is fitted. | DIY Safe |
N/A | The FrostControl won't close any more | Either the FrostControl's own temperature has dropped below roughly 7°C, the rotary switch isn't set to Operation, or the FrostControl itself is faulty | Switch the heater on to bring the temperature above 7°C, turn the rotary switch to Operation, and press the pushbutton in until it clicks. If it's actually faulty, have an authorised service agent replace the valve. | DIY Check / Tech Fallback |
N/A | After the appliance starts, thick smoke keeps coming out of the wall cowl for over a minute | Could be a fuel supply fault, incorrect installation, or a restricted combustion air inlet | Stop using the appliance immediately due to fire hazard and contact customer service or an authorized service agent. | Professional Intervention Required |