Truma Combi D E Next Generation

Official technical documentation and workshop diagnostics for Combi D E.

View official manual on manufacturer's site ↗

Technical Specifications

Operating Voltage12V DC / 230V AC
Power Consumption0.4 – 8.1 A (12V), 900W / 1800W (230V)
Gas Or Pressuremax. 2.8 bar (Pump pressure), max. 4.5 bar (System pressure)
Dimensions Cutout450 x 510 x 300 mm

Master Troubleshooting & Diagnostics Matrix

Error Code / IndicatorSymptom / MeaningPossible CauseStep-by-Step DIY FixSuggested Actions
N/A
The water's taking a really long time to heat up
Water container furred
Descale the water system in accordance with the maintenance instructions.
DIY Safe
N/A
Water's running straight back out - the water container won't fill
Safety / drain valve open
Close the safety / drain valve.
DIY Safe
N/A
The water container won't drain, even with the safety/drain valve open
Either the safety/drain valve's drainage socket is blocked, or a water pipe has frozen
Check opening for dirt such as slush, ice, or leaves and remove if necessary, or thaw the water pipe.
DIY Safe
N/A
Water's dripping or flowing from the safety/drain valve's drainage socket
Water pressure too high
Check the pump pressure stays under 2.8 bar, and fit a pressure reducer if it's connected to mains water.
DIY Safe
N/A
The FrostControl opens after the heater's been switched off
Below roughly 3°C, the FrostControl opens on its own
Switch the heater on - with it off, the FrostControl won't close again until the temperature climbs to around 7°C or above, unless a FrostControl heating element is fitted.
DIY Safe
N/A
The FrostControl won't close any more
Either the FrostControl's own temperature has dropped below roughly 7°C, the rotary switch isn't set to Operation, or the FrostControl itself is faulty
Switch the heater on to bring the temperature above 7°C, turn the rotary switch to Operation, and press the pushbutton in until it clicks. If it's actually faulty, have an authorised service agent replace the valve.
DIY Check / Tech Fallback
N/A
After the appliance starts, thick smoke keeps coming out of the wall cowl for over a minute
Could be a fuel supply fault, incorrect installation, or a restricted combustion air inlet
Stop using the appliance immediately due to fire hazard and contact customer service or an authorized service agent.
Professional Intervention Required