Truma Combi D
Official technical documentation and workshop diagnostics for Combi D.
View official manual on manufacturer's site ↗Technical Specifications
Operating Voltage12V DC / 230V AC
Power Consumption12V: 0.4 - 8.1 A (Heater + water container), 0.5 A (Heating up water container); 230V: 900W (3.9 A) / 1800W (7.8 A)
Gas Or PressurePump pressure max. 2.8 bar, System pressure max. 4.5 bar
Fuse Ratings12V fuse on electronics; 230V fuse (part number 39050-00381)
Dimensions Cutout450 x 510 x 300 mm
Master Troubleshooting & Diagnostics Matrix
| Error Code / Indicator | Symptom / Meaning | Possible Cause | Step-by-Step DIY Fix | Suggested Actions |
|---|---|---|---|---|
W 301 H, W 417 H, E 540 H | Overvoltage > 16.4 V | Battery voltage or voltage sources too high | Check the battery voltage and whatever's supplying it, such as the charger. | DIY Safe |
W 302 H, W 418 H, E 541 H | Low voltage - battery voltage has dropped below 10.0V | Battery voltage has dropped below operating threshold | Charge the battery, fitting a new one if it's old/required. | DIY Safe |
W 303 H, W 411 H | Low voltage risk - battery voltage has dropped below 10.8V | Battery voltage approaching low threshold | Charge battery. | DIY Safe |
E 560 H | The heater's hit its maximum number of start attempts and is locked out | Exceeded allowed failed startup cycles, triggering operation lockout | Contact an authorised service agent. | Professional Intervention Required |
E 561 H | The heater won't start - it's locked out after five failed start attempts | Failure to ignite after five attempts, leading to lockout | Check the fuel supply reaching the appliance. | DIY Safe |
E 565 H | The heater won't start; the flame keeps failing to be detected | Flame failure or lack of fuel detection during operation | Check the fuel supply reaching the appliance. | DIY Safe |
N/A | The water's taking a really long time to heat up | Water container furred | Descale water system | DIY Safe |
N/A | Water's running straight back out - the water container won't fill | Safety / drain valve open | Close safety / drain valve | DIY Safe |
N/A | The water container won't drain, even with the safety/drain valve open | The safety/drain valve's drainage socket is blocked | Look for dirt, slush, ice, leaves or the like in the opening and clear it if needed | DIY Safe |
N/A | The water container won't drain, even with the safety/drain valve open | Water pipe frozen | Thaw water pipe | DIY Safe |
N/A | Water's dripping or flowing from the safety/drain valve's drainage socket | Water pressure too high | Check the pump pressure doesn't exceed 2.8 bar. Fit a pressure reducer if it's hooked up to mains water, to stop the water container seeing higher pressures than that. | DIY Safe |
N/A | The FrostControl opens after the heater's been switched off | Below roughly 3°C, the FrostControl opens on its own | Switch the heater on - with it off, the FrostControl won't close again until the temperature climbs to around 7°C or above, unless a FrostControl heating element is fitted. | DIY Safe |
N/A | The FrostControl won't close any more | The FrostControl's own temperature has dropped below roughly 7°C | Switch the heater on - with it off, the FrostControl won't close again until the temperature climbs to around 7°C or above, unless a FrostControl heating element is fitted. | DIY Safe |
N/A | The FrostControl won't close any more | The rotary switch isn't set to 'Operation' | Turn the FrostControl's rotary switch to 'Operation', then press the pushbutton in until it clicks. | DIY Safe |
N/A | The FrostControl won't close any more | FrostControl faulty | Must be replaced by an authorized service agent | Professional Intervention Required |
N/A | After the appliance starts, thick smoke keeps coming out of the wall cowl for over a minute | Could be a fuel supply fault, incorrect installation, or a restricted combustion air inlet | Stop using the appliance immediately due to fire hazard and contact customer service | Professional Intervention Required |
N/A | In Diesel mode, the heater shows a malfunction after the 230V mains supply is interrupted | A break in the external 230V mains supply while the heater is running in Diesel mode. | Switch the heater off and back on at the control panel to clear the malfunction. If the mains interruption is likely to last longer, switch the heater over to Electro mode instead. | DIY Safe |
N/A | The heater flags a combustion problem | An issue during the combustion process, such as the fuel supply running low. | In Gas mode, the heater automatically switches over to Electro mode - once the underlying cause is fixed, switch the heater off and back on at the control panel to restore normal mixed-mode operation. In Diesel mode, switch the heater off and back on, or switch over to Electro mode if the interruption is expected to last longer. | DIY Safe |