Truma BG 10 BGE 10
Official technical documentation and workshop diagnostics for Boiler BG 10 / BGE 10.
View official manual on manufacturer's site ↗Technical Specifications
Operating Voltage12V DC / 230V AC
Power Consumption12V: Ignition 0.16A, Heating 0.12A, Standby 0.05A; 230V: 850W (3.7A) / 1300W (5.7A)
Gas Or PressureLiquid gas (propane / butane) at 30 mbar
Fuse Ratings1.6A slow-acting fine wire fuse (EN 60127-2-3)
Dimensions CutoutCowl cutout: see technical drawings, max pump pressure 2.8 bar, system pressure max 4.5 bar
Master Troubleshooting & Diagnostics Matrix
| Error Code / Indicator | Symptom / Meaning | Possible Cause | Step-by-Step DIY Fix | Suggested Actions |
|---|---|---|---|---|
N/A | The boiler won't run once switched on (gas mode) | No 12V power supply | Check the battery voltage is at least 10.5V, and check the electronic control unit's fine-wire fuse. Contact an authorised service agent if this doesn't resolve it. | DIY Check / Tech Fallback |
N/A | The boiler won't run once switched on (gas mode) | Window open above cowl | Close the window above the cowl. | DIY Safe |
N/A | The boiler switches on but doesn't run, and the red LED comes on after roughly 30 seconds | Cowl cover is fitted | Take the cowl cover off and clear away any dirt or debris found there. | DIY Safe |
N/A | The boiler switches on but doesn't run, and the red LED comes on after roughly 30 seconds | No gas supply or incorrect gas pressure | Check gas valves and gas cylinder. | DIY Safe |
N/A | The boiler switches on but doesn't run, and the red LED comes on after roughly 30 seconds | Air in gas supply | Switch the appliance off, leave it for 5 minutes to bleed off any trapped air, then switch it back on to clear the fault. | DIY Safe |
N/A | After a long spell of running, the boiler faults out and the red LED comes on | Overtemperature sensor has activated | Close the drain valve and top up the water content if it's low. Switch the appliance off for 5 minutes and back on to clear the fault; if it recurs, contact an authorised service agent. | DIY Check / Tech Fallback |
N/A | The boiler won't run once switched on (BGE 10 electrical mode) | No 230V power supply | Hook the vehicle up to a mains supply and/or check the residual current protective device. | DIY Safe |
N/A | The boiler won't run once switched on (BGE 10 electrical mode) | Overtemperature sensor has activated | Close the drain valve and top up the water content if it's low. The electric heating element has its own overtemperature sensor - turn it off at the control panel, wait 10 minutes and turn it on again. Contact an authorised service agent if the problem persists. | DIY Check / Tech Fallback |
N/A | Heats up too slowly with the switch set to 850W (BGE 10 electrical mode) | Insufficient heating output selected for conditions | Contact Truma Service or an authorized workshop. | Professional Intervention Required |
N/A | Water dripping from drain valve | Water pressure too high | Check the water pressure doesn't exceed 2.8 bar - fit a pressure reducer if connecting to a mains water supply. | DIY Safe |
N/A | Warm water comes out of the cold tap | Hot water is flowing back into the cold supply. | Fit a non-return valve into the cold water supply, following the installation instructions. | DIY Safe |