Master Troubleshooting & Diagnostics Matrix

Error Code / IndicatorSymptom / MeaningPossible CauseStep-by-Step DIY FixSuggested Actions
1 Flash
No Flame Detected
—
Check there's gas in the bottle and the gas line's clear, and use propane rather than butane below +5°C. Clear a lockout by switching it on, off, and on again, completing the whole sequence within 2.5 seconds.
DIY Safe
2 Flashes
Overheat
—
Make sure there's water in the appliance, and give the heater 5-10 minutes to cool before trying the lockout reset: switch off, then on, within 2.5 seconds. If that doesn't clear an overheat lockout, remove the front cover so you can reach the PCB, then press the overheat thermostat's red reset button (it's a manual-reset type).
DIY Safe
3 Flashes
Low/High Supply Voltage
Supply voltage dropped below 10V or rose above 15V.
Operating voltage at the heater should be 10-15V. Check the battery voltage, and if it's in range, check the heater-to-battery connections and the alternator or external charger. Clear the lockout by switching off then on again within 2.5 seconds.
DIY Safe
5 Flashes
Other / internal fault
—
Try clearing the lockout by switching off then back on within 2.5 seconds - contact Propex directly if that doesn't work.
DIY Check / Tech Fallback

Frequently Asked Questions

Q: I want to replace my old Carver Cascade , will I need to cut new holes for the Malaga?

No, we can supply an adapter plate with a new Malaga that will make a neat job of the inlet and exhaust termination.

Q: I have an old Belling Malaga water heater that no longer works, what do I do?

Two options here, we can either supply you a complete replacement Malaga heater or, if its only your control PCB that's failed, we can upgrade your existing Belling unit.

Q: How much does a Malaga water heater cost?

Prices start from £360 + VAT.

Q: What type of pump is needed to work in conjunction with the heater?

The Malaga will work with an in line or submersible pump providing the maximum pressure does not exceed 1.5bar or 20 PSI.

Q: Will it work on an electrical mains hook up?

Yes The Malaga has an integral 750W element so will work from your 230V mains hook up

Q: How large is the Malaga water tank?

13.5 litres

Q: Where can I mount the heater?

Typically in a bedbox or locker with easy access to flue through a side wall.