| Error Code / Indicator | Symptom / Meaning | Possible Cause | Step-by-Step DIY Fix | Suggested Actions |
|---|---|---|---|---|
Low battery | Carbon Monoxide Alarm low battery indication (1 beep/min, 1 amber flash/min) | Low battery power | Replace the batteries. | DIY Safe |
Recommended partAffiliate linksView partHideElddis's 2026 handbook names the FireAngel FA3313, which takes 2x AA batteries (confirmed from FireAngel's product listing). AA batteriesDuracell Plus AA Alkaline Batteries (12 Pack) 1.5V, LR06~£9.00 for 124.7★ (71,000+ ratings), dispatched/sold by Amazon View on Amazon → | ||||
Fault | CO alarm shows a general fault (2 rapid beeps and 2 rapid amber flashes per minute) | Device internal fault; may not detect CO | Replace the alarm straight away - if it's still under warranty, get in touch with Technical Support. | DIY Check / Tech Fallback |
End of life | CO alarm shows an end-of-life indication (3 rapid beeps and 3 rapid amber flashes per minute) | The unit has reached the end of its working life and may no longer reliably detect CO. | Replace the alarm straight away - if it's still under warranty, get in touch with Technical Support. | DIY Check / Tech Fallback |
N/A | The smoke alarm chirps audibly every 40 seconds, signalling a low power pack | The power pack no longer has sufficient capacity for the smoke alarm to operate correctly. | Fit a new smoke alarm straight away. The chirping warning carries on for at least a week, but leave it any longer and the unit may not have enough power left to genuinely warn you if a fire breaks out. | DIY Safe |
Frequently Asked Questions
Q: How do I test the smoke alarm?
Make sure the alarm is correctly clipped onto its base plate first. Press and release the test button in the middle - you should hear two cycles of three loud beeps that stop on their own, with the red LED flashing quickly throughout.
Q: How do I silence a false smoke alarm using Smart Silence?
Press and release the central test button - the alarm goes quiet and drops into reduced sensitivity for around 10 minutes before automatically returning to full sensitivity.
Q: How do I activate the Carbon Monoxide alarm?
Pull the disabling tab out first, then allow up to 60 seconds for the unit's green LED to begin flashing - that confirms it's now active. From there, press the Test button to check the alarm itself is working properly.