Dometic Waeco Coolmatic CF
Official technical documentation and workshop diagnostics for Waeco Coolmatic CF.
Technical Specifications
ElectricalOperating voltage: 12V / 24V DC and 100-240V AC (models CF-35 to CF-110 have integrated multi-voltage power supply; CF-18 and CF-25 require MOBITRONIC EPS-100W or MPS-35 rectifier for AC). Nominal current DC 12V: 3.1A (CF-18), 6.8A (CF-25), 6.0A (CF-35, CF-40), 7.0A (CF-50, CF-80, CF-110). Nominal current DC 24V: 1.9A (CF-18), 3.0A (CF-25 to CF-110). Nominal AC 100-240V: 1.3-0.7 A. Extension cord requirement (if used): UL/CSA-listed, minimum 15 A rating at 120 V.
Gas Or PressureCFC-free refrigerant circuit. Operating ambient temperature: -10 °C to +55 °C. Maximum continuous heel/inclination: 30 degrees. Battery monitor cut-out voltages (12V): Low 10.4V, Med 11.0V (or High 11.5V depending on model/setting); Cut-out voltages (24V): Low 21.6V / 22.1V, Med 23.3V, High 24.0V / 25.0V. Cut-in voltages (12V): Low 11.2V / 11.5V, Med 12.0V, High 12.5V / 12.9V; Cut-in voltages (24V): Low 23.0V / 23.6V, Med 24.5V, High 25.4V / 26.3V.
Capacities DimensionsCapacities: CF-18 (18 L), CF-25 (23 L), CF-35 (31 L), CF-40 (37 L), CF-50 (49 L), CF-80 (80 L), CF-110 (106 L). Weights: CF-18 (11 kg), CF-25 (14 kg), CF-15/CF-35 (15 kg), CF-40 (16 kg), CF-50 (18 kg), CF-80 (23 kg), CF-110 (25 kg). Temperature control range: +10 °C to -18 °C.
Master Troubleshooting & Diagnostics Matrix
| Error Code / Indicator | Symptom / Meaning | Possible Cause | Step-by-Step DIY Fix | Suggested Actions |
|---|---|---|---|---|
N/A | Error LED flashes red / appliance not ready to operate | Insufficient battery voltage or poor connection causing the battery monitor to trip | Check battery charge status, ensure proper cable cross-sections, and clear loose connections or corrosion at battery terminals. | DIY Safe |
N/A | Appliance fails to run on 12V/24V DC | Blown fuse or reversed polarity | Check device fuse and replace with identical specification fuse if blown. Verify correct positive and negative polarity wiring. | DIY Safe |
N/A | Reduced cooling performance / ice build-up on evaporator | Heavy frost accumulation on evaporator due to humidity or blocked condenser airflow | Defrost the appliance completely, wipe dry, ensure adequate ventilation around the condenser, and keep the lid closed tightly. | DIY Safe |