Dometic • Portable Compressor Cooler / Refrigerator

Dometic Waeco Coolmatic CF

Official technical documentation and workshop diagnostics for Waeco Coolmatic CF.

Technical Specifications

ElectricalOperating voltage: 12V / 24V DC and 100-240V AC (models CF-35 to CF-110 have integrated multi-voltage power supply; CF-18 and CF-25 require MOBITRONIC EPS-100W or MPS-35 rectifier for AC). Nominal current DC 12V: 3.1A (CF-18), 6.8A (CF-25), 6.0A (CF-35, CF-40), 7.0A (CF-50, CF-80, CF-110). Nominal current DC 24V: 1.9A (CF-18), 3.0A (CF-25 to CF-110). Nominal AC 100-240V: 1.3-0.7 A. Extension cord requirement (if used): UL/CSA-listed, minimum 15 A rating at 120 V.
Gas Or PressureCFC-free refrigerant circuit. Operating ambient temperature: -10 °C to +55 °C. Maximum continuous heel/inclination: 30 degrees. Battery monitor cut-out voltages (12V): Low 10.4V, Med 11.0V (or High 11.5V depending on model/setting); Cut-out voltages (24V): Low 21.6V / 22.1V, Med 23.3V, High 24.0V / 25.0V. Cut-in voltages (12V): Low 11.2V / 11.5V, Med 12.0V, High 12.5V / 12.9V; Cut-in voltages (24V): Low 23.0V / 23.6V, Med 24.5V, High 25.4V / 26.3V.
Capacities DimensionsCapacities: CF-18 (18 L), CF-25 (23 L), CF-35 (31 L), CF-40 (37 L), CF-50 (49 L), CF-80 (80 L), CF-110 (106 L). Weights: CF-18 (11 kg), CF-25 (14 kg), CF-15/CF-35 (15 kg), CF-40 (16 kg), CF-50 (18 kg), CF-80 (23 kg), CF-110 (25 kg). Temperature control range: +10 °C to -18 °C.

Master Troubleshooting & Diagnostics Matrix

Error Code / IndicatorSymptom / MeaningPossible CauseStep-by-Step DIY FixSuggested Actions
N/A
Error LED flashes red / appliance not ready to operate
Insufficient battery voltage or poor connection causing the battery monitor to trip
Check battery charge status, ensure proper cable cross-sections, and clear loose connections or corrosion at battery terminals.
DIY Safe
N/A
Appliance fails to run on 12V/24V DC
Blown fuse or reversed polarity
Check device fuse and replace with identical specification fuse if blown. Verify correct positive and negative polarity wiring.
DIY Safe
N/A
Reduced cooling performance / ice build-up on evaporator
Heavy frost accumulation on evaporator due to humidity or blocked condenser airflow
Defrost the appliance completely, wipe dry, ensure adequate ventilation around the condenser, and keep the lid closed tightly.
DIY Safe