| Error Code / Indicator | Symptom / Meaning | Possible Cause | Step-by-Step DIY Fix | Suggested Actions |
|---|---|---|---|---|
Red, slowly flashing | Battery undervoltage or battery overload | Battery voltage is too low or battery is overloaded. | Check the battery, and switch the charger off and back on. Contact an authorised service agent if this doesn't resolve it. | DIY Check / Tech Fallback |
Red, slowly flashing | Defective battery | The connected battery is damaged or defective. | Replace the battery. | DIY Safe |
Red, slowly flashing | Overheating | Internal temperature is too high due to restricted ventilation or high ambient temperature. | Improve ventilation around the charger or battery, make sure no vents are covered, and reduce the ambient temperature if needed. | DIY Safe |
Red, permanently lit | Short circuit or reversed polarity | Polarity of battery connection is reversed or a short circuit exists. | Connect the charger with the correct polarity, clear the short circuit, and check whether the fuse has tripped, replacing it if needed. | DIY Safe |
Red, double flash | Fan fault | Cooling fan is blocked, dirty, or damaged. | Inspect the fan for damage or dirt. If it's actually faulty, have a specialist or authorised workshop carry out repairs. | DIY Check / Tech Fallback |
Red, slow double flash | The starter battery connection is faulty | Short circuit at the starter battery connection. | Check the starter battery connection for a short circuit. | DIY Safe |