Dometic Liquefied Gas Cooktop / Sink Combination
Official technical documentation and workshop diagnostics for Liquefied Gas Cooktop / Sink Combination.
View official manual on manufacturer's site ↗Technical Specifications
Electrical12 VDC connection voltage for models with electronic ignition, 1 A fuse in the positive line near the battery
Gas Or PressureGas Category I 3 B/P(30) at 30 mbar for propane (G31) and butane (G30) in AT, DE, BG, CY, DK, EE, FI, GR, HU, IS, LT, LV, MT, NL, NO, RO, SE, SI, SK, AL, HR, MK, TR. Gas Category I 3+ at 37 mbar for propane (G31) and 28-30 mbar for butane (G30) in BE, CH, CY, CZ, ES, FR, GB, GR, IE, IT, LT, PL, PT, SI, SK, AL, MK, TR.
Capacities DimensionsAir vent requirement: minimum cross-section of 150 cm2 in the installation space. Steel pipe connection: diameter 8 x 1 mm (welded, seamless steel, or stainless steel).
Master Troubleshooting & Diagnostics Matrix
| Error Code / Indicator | Symptom / Meaning | Possible Cause | Step-by-Step DIY Fix | Suggested Actions |
|---|---|---|---|---|
N/A | [Gas] Flame goes out automatically during operation | Automatic flame monitoring device activated due to flame extinction or thermocouple failure | Check flame stability, ensure no drafts are present at the installation location, and inspect thermocouple and gas supply. | DIY Safe |
N/A | [Gas] Gas leak or smell of gas detected | Loose gas pipe connections or damaged gas line | Shut the gas cylinder valve straight away, open the windows, clear the room, and check every connection with leak-detection spray (no bubbles should form). | Professional Intervention Required |
N/A | [Mechanical/Water] Safety glass cover breakage | Impact or thermal stress on the glass lid | Immediately shut off every burner and electrical heating element, isolate the appliance from the power supply, avoid touching the surface, and have the glass assembly replaced. | DIY Check / Tech Fallback |
