Technical Specifications

Operating Voltage110 – 230 V AC / 50 – 60 Hz
Fuse RatingsF 16 A / 5 x 30 mm
Dimensions Cutout85 x 50 x 210 mm

Master Troubleshooting & Diagnostics Matrix

Error Code / IndicatorSymptom / MeaningPossible CauseStep-by-Step DIY FixSuggested Actions
Red, flashing
Status LED flashes red and a cable has been disconnected
A cable has been disconnected or the battery is defective
Check the cables and connections. If the battery is defective, replace the battery.
DIY Safe
Red, permanently lit
Status LED is permanently lit red due to no supply voltage
No supply voltage is present
Check the mains supply's connections and cables.
DIY Safe
Red, permanently lit
Status LED is permanently lit red due to inverse polarity
Reverse polarity on battery connections
Connect the automatic charger the right way round (correct polarity), and check whether the fuse has tripped and replace it if needed (type F 16A/5x30mm).
DIY Safe
Red, permanently lit
Status LED is permanently lit red due to overheating
Thermal overload from high ambient temperature or blocked ventilation
Improve ventilation around the automatic charger, make sure no vents are covered, and reduce the ambient temperature if needed.
DIY Safe