Dometic HiPro
Official technical documentation and workshop diagnostics for HiPro.
View official manual on manufacturer's site ↗Technical Specifications
ElectricalInput Voltage: 220 V – 240 V AC, 50/60 Hz (Absorption A series & Compressor C series); 100 V – 240 V AC, 50/60 Hz (Thermoelectric N series). Rated input power: 60 W – 70 W (Absorption A series), 45 W (Compressor C series), 55 W (Thermoelectric N series). Light source energy efficiency class: F.
Gas Or PressureRefrigerants: R717 (Ammonia for Absorption series), R600a (Compressor & Thermoelectric series). Absorber unit is under high pressure.
Capacities DimensionsTotal Volume: 26 L (A30, N30), 33 L (A40, C40, N40), 49 L (C60). Climate Class: N (16°C – 32°C), T (16°C – 43°C). Noise Emission: 0 dB(A) for A and N series; 33 dB(A) for C40; 38 dB(A) for C60.
Master Troubleshooting & Diagnostics Matrix
| Error Code / Indicator | Symptom / Meaning | Possible Cause | Step-by-Step DIY Fix | Suggested Actions |
|---|---|---|---|---|
N/A | The minibar isn't cooling, and its indicator LED is off. | Power plug not plugged in, no voltage at socket, defective electronics fuse, defective heating cartridge (absorption models), or defective electronics/temperature sensors/cooling unit. | Insert power plug, check circuit breaker, and have authorized service agent replace fuse, heating cartridge, NTC sensor, electronics, or cooling unit/minibar as needed. | DIY Check / Tech Fallback |
N/A | The minibar isn't cooling, and the indicator LED flashes orange once. | NTC sensor is defective. | Contact an authorized service agent to replace the NTC sensor. | Professional Intervention Required |
N/A | The minibar isn't cooling, and the indicator LED flashes orange 3 times. | Heating cartridge is defective (absorption models only). | Contact an authorized service agent to install a new heating cartridge. | Professional Intervention Required |
N/A | The minibar isn't cooling, and the indicator LED flashes orange 5 times. | CPC (cooling performance control) error. | Temporarily disconnect minibar from power supply to reset error. Count flashes post-reset (1x = NTC error, 3x = heating cartridge error, no flashing = error reset). Contact service agent if 1x or 3x flashes persist. | DIY Check / Tech Fallback |
N/A | The minibar isn't cooling, and the interior light flashes continuously. | Error during self-test of the cooling unit (absorption models). | Check cooling unit for leaks, check ventilation grille, and wait 24 hours for device to restart. If it does not restart, contact an authorized service agent. | DIY Check / Tech Fallback |
N/A | Poor cooling performance. | Cooling unit not sufficiently ventilated, direct sunlight exposure, door not sealed tightly, recently filled with goods, or input voltage too high/low (absorption models). | Provide sufficient ventilation, remove from direct sunlight, check/replace door seal, re-check cooling after 5 to 6 hours, and check input voltage. | DIY Safe |
N/A | Interior lighting is not working. | Defective interior lighting or infrared door sensor surface covered (e.g., by condensation). | Clean the infrared door sensor's surface, or have an authorised service agent replace the interior lighting. | DIY Check / Tech Fallback |
N/A | Frost formation in the minibar compartment | The minibar keeps cooling non-stop, dropping below the set temperature | Contact an authorized service agent. | Professional Intervention Required |