Technical Specifications

ElectricalOperating Voltage: 12V DC or 24V DC. Average Power Consumption: 61 W. Current Consumption at 25°C/32°C: 3.3 Ah/h / 5.1 Ah/h. Cut-off Voltage: 10.4 V (12V) / 22.8 V (24V). Reconnection Voltage: 11.7 V (12V) / 24.2 V (24V). Minimum fuse rating: 15 A (at 12 V) or 7.5 A (at 24 V). Internal Light: LED bulb, E14, 12/24 V, 1.2 W.
Gas Or PressureRefrigerant circuit contains R134a.
Capacities DimensionsTotal Net Capacity: 277 l. Refrigerator Capacity: 202 l. Freezer Capacity: 75 l. Climate Class: ST (+16 °C to +38 °C). Max humidity: 90%. Constant heel/inclination limit: max 30°. Weight: approx. 52 kg. Dimensions: 540 mm (W) x 550 mm (D) x 1775 mm (H).

Master Troubleshooting & Diagnostics Matrix

Error Code / IndicatorSymptom / MeaningPossible CauseStep-by-Step DIY FixSuggested Actions
N/A
Compressor does not run (UKL = 0 V)
Interruption in connection cable between battery and electronics, defective main switch, or blown auxiliary inline fuse.
Establish connection, replace main switch, or replace inline fuse.
DIY Safe
N/A
Compressor does not run with battery voltage too low (UKL <= UTIL)
Low battery voltage, loose cable connection, poor connection (corrosion), low battery capacity, or cable cross-section too small.
Charge battery, fix/clean connection, replace battery, or replace cable with correct cross-section according to manual charts.
DIY Safe
N/A
Compressor does not run despite sufficient voltage (UKL >= UTIL)
The surroundings are too hot or poorly ventilated, the condenser is dirty, the fan is faulty, or there's an electrical break inside the compressor.
Relocate refrigerator, clean condenser, replace fan, or replace compressor.
DIY Check / Tech Fallback
N/A
Compressor runs constantly (Inner temperature too cold on setting '1')
Thermostat sensor has no contact with the evaporator, or short circuit in thermostat line / defective thermostat.
Fasten sensor or replace thermostat.
DIY Check / Tech Fallback
N/A
Cooling capacity reduced, inner temperature rises (Compressor runs long/constantly)
Frost building up on the evaporator, surroundings that are too hot or poorly ventilated, a dirty condenser, or a faulty fan.
Defrost evaporator, relocate refrigerator, clean condenser, or replace fan.
DIY Check / Tech Fallback
N/A
Water inside or under the refrigerator
The water drain channel is blocked, food is stopping water reaching the collector, or the air deflector is holding too much water.
Clean drain using the provided cleaning tool, rearrange food items so they do not touch the back wall, and clean the air separator.
DIY Safe
N/A
Unusual noises (Loud humming)
A component of the cooling circuit cannot swing freely (touching the wall) or foreign object jammed between cooling unit and wall.
Carefully bend component away or remove foreign object.
DIY Safe

Frequently Asked Questions

Q: What can replace my old Dometic RM fridge?

Dometic's 2023 'New for old - simply swap' guide covers both its absorption and compressor fridges, showing which current models replace older ones. It's available from the catalogues section of Dometic's website.