Technical Specifications

Electrical12 V DC or 24 V DC, Average power consumption: 45 W, Cut-off voltage: 10.4 V (12 V) / 22.8 V (24 V), Cut-in voltage: 11.7 V (12 V) / 24.2 V (24 V), Minimum supply line fuse: 15 A (at 12 V) / 7.5 A (at 24 V)
Gas Or PressureRefrigerant circuit contains R134a
Capacities DimensionsCapacity: 47 l (approx. 50 l), Dimensions (WxHxD): 448 x 527 x 543 mm, Weight: 25 kg, Constant inclination: max. 30°, Maximum relative air humidity: 90%, Ambient operating temperature range: +18 °C to +32 °C (Compressor starts at > +16 °C)

Master Troubleshooting & Diagnostics Matrix

Error Code / IndicatorSymptom / MeaningPossible CauseStep-by-Step DIY FixSuggested Actions
N/A
Compressor does not run (UKL = 0 V)
Interruption in the connection between battery and electronics, faulty main switch, or blown additional supply line fuse
Establish a secure connection, replace the main switch, or replace the supply line fuse
DIY Safe
N/A
Compressor does not run (UKL <= UOFF / Battery voltage too low)
Loose cable connection, poor contact (corrosion), low battery capacity, or too small cable cross section
Clean/secure connections, charge or replace the battery, or replace the cable with a correct cross-section according to the manual gauge chart
DIY Safe
N/A
Compressor does not run (Ambient temperature too low)
Usage when ambient temperature is below +16 °C
Only run the freezer where the ambient temperature's above +16°C.
DIY Safe
N/A
Compressor runs constantly or for a long time
Could be the thermostat sensor losing contact with the vaporiser, a faulty thermostat, an iced-up vaporiser, or poor ventilation.
Secure the sensor, replace the thermostat, defrost the vaporiser, or move the freezer to improve ventilation and clean the condenser
DIY Check / Tech Fallback
N/A
Poor cooling, interior temperature increases
Condenser is dirty, defective fan, or exhausted battery capacity
Clean the condenser, replace the fan, or charge the battery
DIY Check / Tech Fallback
N/A
Unusual noises (Loud humming)
Either part of the refrigerant circuit is touching the wall so can't move freely, or something is wedged behind the cooling unit.
Carefully bend the component away from the obstruction or remove the foreign body