Dometic • Remote Control for Blind Systems

Dometic AP Remote Control

Official technical documentation and workshop diagnostics for Dometic AP Remote Control.

Technical Specifications

ElectricalSupply voltage: 2 V … 3.5 V (2 AAA batteries, 1.5 V). Radio frequency: 433 MHz. Transmitting power: 10 mW.
Gas Or PressureNot applicable
Capacities DimensionsWeight (including batteries): 80 g. Storage temperature: –25 °C … 75 °C. Operating temperature: –20 °C … 65 °C. Humidity: ≤ 90%.

Master Troubleshooting & Diagnostics Matrix

Error Code / IndicatorSymptom / MeaningPossible CauseStep-by-Step DIY FixSuggested Actions
N/A
Blind does not respond to the AP remote control (No power)
Battery drained or power supply issue to the blind
Check battery and check power to the blind.
DIY Safe
N/A
Blind does not respond to the AP remote control (Wrong channel)
Incorrect channel number selected
Check channel number.
DIY Safe
N/A
Blind does not respond to the AP remote control (Thermal cut-out)
Repeated or prolonged use caused thermal cut-out to activate
Wait 20 minutes for the motor's thermal cutout to reset.
DIY Safe
N/A
Blind does not respond to the AP remote control (Pairing issue)
Wrong or lost pairing
Re-pair the AP remote control with the blind.
DIY Safe
N/A
The blind moves the wrong way
Wrong setting
Change direction of blind.
DIY Safe
N/A
More than one blind moves
Multiple blinds paired to each channel or set to channel P
Switch channels to control other blinds, or un-pair motors you don't want from the AP remote.
DIY Safe
N/A
The display doesn't show a channel number
No power
Check battery.
DIY Safe
N/A
The AP remote isn't behaving as expected
Programming timeout
Note the system drops out of programming mode automatically if no button is pressed for 30 seconds - don't leave long gaps between programming steps.
DIY Safe