Dometic • Refrigerator/Compressor Refrigerator

Dometic 10-Series Compressor Refrigerators

Official technical documentation and workshop diagnostics for 10-Series Compressor Refrigerators.

View official manual on manufacturer's site ↗

Technical Specifications

ElectricalConnection voltage 12 V / 24 V DC. Power consumption ranges from 7 A / 3.5 A (standard models) to 7.2 A / 3.6 A (larger models like RCD10.5). Energy consumption varies by model from 0.34 kWh/24h to 0.75 kWh/24h. Fan load limit on electronics unit is more than 1 A.
Gas Or PressureRefrigerant type: R600a. Refrigerant charge varies by model: 13.5 g (RC10.4P.70), 14.5 g (RC10.4G.90, RC10.4P.90, RC10.4P.9M), 17 g (RC10.4P.P), 18 g (RCS10.5), 20 g (RCL10.4), 33 g (RCD10.5EG/EP), 35 g (RCD10.5X). Global Warming Potential (GWP): 0. CO2 equivalent: 0.
Capacities DimensionsGross capacities range from 69 L (RC10.4P.70) up to 200 L (RCD10.5XEP). Maximum weight per door shelf: 3 kg. Maximum weight per refrigerator door: 7.5 kg. Operating humidity maximum: 90%.

Master Troubleshooting & Diagnostics Matrix

Error Code / IndicatorSymptom / MeaningPossible CauseStep-by-Step DIY FixSuggested Actions
N/A
The refrigerator does not work
Could be a blown DC-cable or vehicle fuse, a flat vehicle battery, the ignition being off, or a faulty DC heating element.
Replace the DC cable fuse, replace the vehicle fuse, test and charge the vehicle battery, switch on the ignition, or contact an authorized service agent.
DIY Check / Tech Fallback
N/A
The refrigerator isn't cooling as well as it should.
Could be poor ventilation around the cooling unit, an iced-up evaporator, too high a temperature setting, too-high ambient temperature, or too much warm food added at once.
Check the ventilation grille isn't blocked, defrost the fridge, lower the temperature setting, take the grille off temporarily to help heat escape, or let warm food cool before loading it in.
DIY Safe
N/A
Refrigerator door/frozen compartment door does not close
The door handle's jammed on the open side.
Remove the door handle blockage.
DIY Safe
N/A
Refrigerator door/frozen compartment door has completely detached from the device
The locking pins have been tampered with or are twisted.
Reinsert and re-align the door locking pins.
DIY Safe
N/A
Error: Under or over voltage (1 flash)
The supply voltage's outside the set range.
Check supply voltage and vehicle charging system to ensure proper operating range.
DIY Safe
N/A
Error: Excessive fan current (2 flashes)
The fan's drawing more than 1A.
Check the external fan for blockages or short circuits, replace if faulty.
DIY Safe
N/A
Error: The motor does not start (3 flashes)
Either the rotor's jammed, or the cooling system's pressure differential is too high.
Check compressor clearance/rotor movement and allow system pressure to equalize.
DIY Safe
N/A
Error: Speed too low (4 flashes)
The cooling system's overloaded, so the motor can't hold its minimum speed.
Reduce internal load, improve ventilation, or clear heat sources around the appliance.
DIY Safe
N/A
Error: Overheating of the electronics unit (5 flashes)
A heavily loaded cooling system, or too high a temperature setting, is overheating the electronics.
Improve cabinet ventilation, remove obstructions from grilles, and ensure ambient air can circulate freely.
DIY Safe
N/A
Error: Temperature sensor errors (Constant flash)
Temperature sensor is defective.
Check the temperature sensor connection or replace the defective sensor.
DIY Safe

Frequently Asked Questions

Q: What can replace my old Dometic RM fridge?

Dometic's 2023 'New for old - simply swap' guide covers both its absorption and compressor fridges, showing which current models replace older ones. It's available from the catalogues section of Dometic's website.