Official technical documentation and workshop diagnostics for PL50-ST2.

Master Troubleshooting & Diagnostics Matrix

Error Code / IndicatorSymptom / MeaningPossible CauseStep-by-Step DIY FixSuggested Actions
Symbol ref. 17
Car battery (B1) has run down
Car battery voltage goes below 12V
The alarm goes off when the voltage goes above 12.5V.
DIY Safe
Symbol ref. 18, two short beeps
Leisure battery (B2) has run down
Leisure battery voltage reaches 10.5V
Alarms go off when the voltage goes above 12.5V.
DIY Safe
Symbol ref. 18, one short beep
Leisure battery (B2) reserve alarm
Leisure battery voltage reaches 11.5V
Alarms go off when the voltage goes above 12.5V.
DIY Safe
Symbol ref. 21
Minimum voltage protection device is on
Leisure battery reaches the preset threshold, disconnecting 12V users
Users are automatically reconnected with a voltage higher than 13.5V. It is possible to connect all users for one more minute by pressing the on/off button on the control panel. With a voltage lower than 9.5V the control panel automatically turns off.
DIY Safe
Symbol ref. 19, acoustic signal (when engine is off)
Fresh water tank is empty
Fresh water level goes below 10% of the tank capacity
Alarm automatically turns off when level exceeds 20%.
DIY Safe
Symbol ref. 20 blinking, acoustic signal (when engine is off)
Waste water tank is full
Waste water level goes over the screw sensor level
To reset alarm press any test button; to exit this function press buttons ref. 2 or 3.
DIY Safe
Red LED lit under the fuse
Broken fuse alarm
Fuse is broken
Before replacing the fuse find the problem that determined the system to intervene and in case, have it fixed by relying on expert technicians. Replace with another fuse with the same value.
DIY Check / Tech Fallback