CBE • Carbon Monoxide Alarm

CBE BMTCO

Official technical documentation and workshop diagnostics for BMTCO.

Master Troubleshooting & Diagnostics Matrix

Error Code / IndicatorSymptom / MeaningPossible CauseStep-by-Step DIY FixSuggested Actions
Red LED 1 flash every 2 seconds, buzzer with intermittent sound
Carbon monoxide concentration has exceeded the alarm threshold
CO has reached one of the alarm thresholds - 50ppm sustained for 60-90 minutes, 100ppm for 10-40 minutes, or 300ppm for as little as 3 minutes
Ventilate the room immediately. Where possible, turn off anything that could be producing carbon monoxide - gas fridges, cookers, combustion engines and similar - and don't use them again until a specialist engineer has checked them. Power the detector off and back on to reset it; if the alarm comes straight back on, evacuate the room. If anyone shows symptoms like headache, dizziness or nausea, get medical help immediately.
Professional Intervention Required
Red LED turning on continuously
Detector malfunction
The detector's own electronics or sensor have developed a fault
Replace the device.
DIY Safe