Master Troubleshooting & Diagnostics Matrix

Error Code / IndicatorSymptom / MeaningPossible CauseStep-by-Step DIY FixSuggested Actions
2 yellow LED flashes
Battery charger over-temperature alarm
—
The alarm clears itself automatically once the charger has cooled down - check that it has adequate ventilation.
DIY Safe
3 yellow LED flashes
Unsuitable battery voltage alarm
—
Use only 12V batteries.
DIY Safe
4 yellow LED flashes
Unsuitable mains voltage alarm
—
Confirm the mains supply is within the 187-264V range. Contact technical support if the alarm keeps recurring.
DIY Check / Tech Fallback
5 yellow LED flashes
Battery charge alarm defective
—
Disconnect the power supply to clear the alarm. Contact technical support if it keeps coming back.
DIY Check / Tech Fallback
6 yellow LED flashes
Battery over-temperature alarm (t > 50°C)
Battery temperature > 50°C
Charging pauses briefly and the alarm clears itself once the battery has cooled - check the battery compartment's ventilation, or the battery's own condition, if this keeps happening.
DIY Safe
7 yellow LED flashes
Overcurrent alarm
—
If the alarm recurs, consult technical support.
Professional Intervention Required
8 yellow LED flashes
Short circuit alarm
—
The alarm clears itself automatically once the short circuit at the output has been cleared.
DIY Safe
9 yellow LED flashes
Overvoltage alarm
—
If the alarm recurs, consult technical support.
Professional Intervention Required