Covers: Broadway, Bourton, Burford
+5 more
Corinium, Malvern, Nuevo, Stanton, WinchcombeNuevo models: EK, ES
Broadway models: EB, EK, EK TB, EL, FB
Corinium models: Duo, FB
Auto-Sleepers Gas Supply System
(Coachbuilt, 2021 Model Year)
Master Troubleshooting & Diagnostics Matrix
| Error Code / Indicator | Symptom / Meaning | Possible Cause | Step-by-Step DIY Fix | Suggested Actions |
|---|---|---|---|---|
N/A | Appliance will not light (LPG) | No gas | Check isolation tap is open | DIY Safe |
N/A | Appliance will not light (LPG) | Low battery (auto ignition) | Charge battery | DIY Safe |
N/A | The appliance lights but goes straight out again as soon as the FSD override is released. | Flame supervision device (FSD) not functioning correctly | Refer to dealer | Professional Intervention Required |
N/A | Odour of gas | Gas leak | Cut the gas off at the cylinder and hold off using the system until the fault's resolved. Air the vehicle out by opening doors and windows so any escaped gas can clear, and let the site warden and/or your local gas supplier know if a cylinder looks like it's leaking. | Professional Intervention Required |
N/A | Yellow flame | Not enough primary air is reaching the burner (a little yellow tipping on the flame is expected and not a fault). | Refer to dealer | Professional Intervention Required |
N/A | Orange flame | Dust or dirt has collected in the mixing tube and is reaching the burner ports. | Cut down the level of dust in the surrounding air. | DIY Safe |
N/A | Orange flame | Burner ports partially blocked | Refer to dealer | Professional Intervention Required |
N/A | Floating flame | Lack of secondary air | Make sure every vent is clear (the vehicle's air inlet included); for an oven, also check the flue way isn't blocked. | DIY Safe |