Master Troubleshooting & Diagnostics Matrix

Error Code / IndicatorSymptom / MeaningPossible CauseStep-by-Step DIY FixSuggested Actions
N/A
Appliance will not light
No gas
Check isolation tap is open
DIY Safe
N/A
Appliance will not light
Low battery (auto ignition)
Charge battery
DIY Safe
N/A
Appliance lights but goes out immediately the FSD override is released
Flame supervision device (FSD) is not functioning correctly
Refer to dealer
Professional Intervention Required
N/A
Odour
Gas leak
Close the gas isolation tap and leave the system switched off until the fault's resolved. A cylinder that looks like it's leaking should be reported to the site warden and/or your local gas supplier.
Professional Intervention Required
N/A
Yellow flame
There isn't enough primary air reaching the burner - note that a little yellow tipping on the flame is normal and not a fault.
Refer to dealer
Professional Intervention Required
N/A
Orange flame
Dust or dirt particles in the mixing tube are being carried through the burner ports.
Reduce the level of dust in the surrounding air.
DIY Safe
N/A
Orange flame
Burner ports partially blocked
Refer to dealer
Professional Intervention Required
N/A
Floating flame
Lack of secondary air
Make sure every vent is clear, including the vehicle's air inlet.
DIY Safe
N/A
Floating flame
Blocked retention ports
Make sure the retention ports aren't blocked; on an oven, also confirm the flue way isn't obstructed.
DIY Safe